BSSQX - UNI-PACK 5LBS, 53922 LUBRI-PACK PACKING
- MSDS: BSSQX
- Manufacturer: PREMIER INDUSTRIAL CORP
- Product Name: UNI-PACK 5LBS, 53922 LUBRI-PACK PACKING
- National Stock Number: 9150-00N040988
Product Identification
Product ID:UNI-PACK 5LBS, 53922 LUBRI-PACK PACKING
MSDS Date:04/01/1992
FSC:9150
NIIN:00N040988
MSDS Number: BSSQX
Responsible Party
CLEVELAND, OH 44103
US
Emergency Phone: 216-391-8300
Info Phone: 216-391-8300
Cage: 18399
Contractor
Telephone: 216-391-8300
Cage: 18399
Ingredients
LEAD
CAS: 7439-92-1
RTECS: OF7525000
Fraction By Weight: 59%
OSHA PEL 0.05 MG/M3
ACGIH TLV: 0.15 MG/M3
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
MOLYBDENUM DISULFIDE
CAS: 1317-33-5
RTECS: QA4697000
Fraction By Weight: 2.5%
OSHA PEL 5 MG/M3 (MO)
ACGIH TLV: 5 MG/M3 (MO)
GRAPHITE
CAS: 7782-42-5
RTECS: MD9659600
Fraction By Weight: 0.5%
OSHA PEL 2.5 MG/M3 RDUST
ACGIH TLV: 2 MG/M3
MINERAL OIL, PETROLEUM DISTILLATES, HYDROTREATED (SEV)
CAS: 64742-52-5
RTECS: PY8035001
Fraction By Weight: 12%
OSHA PEL 5 MG/M3
ACGIH TLV: 5 MG/M3
ETHYLENE, TETRAFULORO-, POLYMER; (POLYTETRAFLUOROETHYLENE)
CAS: 116-14-3
RTECS: KX4025000
Fraction By Weight: 9%
G.F.O. FIBER
Fraction By Weight: 17%
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: HARMFUL/FATAL IF SWALLOWED. MAY
CAUSE BIRTH DEFECTS. POSSIBLE CUMULATIVE OR IRREVERSIBLE EFFECTS TO
THE CNS. MAY CAUSE SKIN IRRITATION. NOTE: LEAD APPEARS ON NAVY
LISTING OF OCCUPATIONAL REPROD UCTIVE HAZARD. SEEK CONSULTATION
FROM APPROPRIATE HEALTH PROFESSIONALS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: CONCERNING LATEST HAZARD LIST
INFORMATION AND SAFE HANDLING AND EXPOSURE RECOMMENDATIONS .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYE: IMMED FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES
AND CALL PHYSICIAN. SKIN: WASH THORO WITH PLENTY OF WATER AND SOAP.
INHAL: REMOVE TO FRESH AIR. ADMINISTER OXYGEN AND CALL PHYSICIAN.
INGE ST: SEEK PHYSICIAN IMMED. SHOW MSDS OR LABEL, INDUCE VOMITING.
IN CASE OF ACCIDENT/ILLNESS, SEEK MD IMMED.
Fire Fighting
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:CONTACT WITH FLAME/HOT SURFACES MAY
PRODUCE TOXIC GASES.
Accidental Release
Spill Release Procedures:CONTAIN AND PICK-UP WASTE MATERIALS. PUT INTO
A SEALED APPROVED CONTAINER. REPORTABLE QTY: 1 LB.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AVOID CONT W/EYES & SKIN. DO NOT TAKE
INTERNALLY. CONT W/FLAME/HOT SURF MAY PRDE TOX GASES. DO NOT USE
PROD WHILE EAT, DRINK/USING TOBACCO PROD.
Other Precautions:KEEP OUT OF REACH OF CHILDREN. KEEP ONLY IN ORIGINAL
LBLD CONTRS. DO NOT EMPTY INTO WATERWAYS. ALWAYS READ & FOLLOW
DIRECTIONS ON PRODUCT LABEL. ADDNL MATL SFTY DATA SHEETS ARE AVAIL
UPON REQUEST. FOR PROFESSIONAL & INDUST USE ONLY.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED HIGH EFFICIENCY RESPIRATOR
FOR DUST/FUME.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
Solubility in Water:INSOLUBLE
Appearance and Odor:VISCOUS BLACK AND WHITE SUBSTANCE W/LEAD SHOT;
ORGANIC ODOR
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZERS, AMMONIUM OXIDES.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:SULFIDES METALLIC AND SULFUR OXIDES.
Disposal
Waste Disposal Methods:DISPOSE OF WASTES IN ACCORDANCE WITH FEDERAL,
STATE, AND LOCAL REGULATIONS. HAZ WASTE # D008.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.