BLBYR - YORK C OIL
- MSDS: BLBYR
- Manufacturer: DELTA PETROLEUM CO INC
- Product Name: YORK C OIL
- National Stock Number: 9150-00N017020
Product Identification
Product ID:YORK C OIL
MSDS Date:09/08/1988
FSC:9150
NIIN:00N017020
MSDS Number: BLBYR
Responsible Party
US
Emergency Phone: 504-833-2861
Preparer: J R SWOAP
Cage: 7A348
Contractor
Telephone: 504-832-2732
Cage: 7A348
Ingredients
PETROLEUM; (PETROLEUM OIL). LIMITS AS MINERAL OIL MIST.
CAS: 8002-05-9
RTECS: SE7175000
Fraction By Weight: 100%
OSHA PEL 5 MG/M3
ACGIH TLV: 5MG/M3;10 MG/M3,STEL
Hazards
LD50 LC50 Mixture:ORAL RAT: >5G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES/SKIN: BELIEVED TO BE
MINIMALLY IRRITATING. RESPIRATORY SYSTEM: BELIEVED TO BE MINIMALLY
IRRITATING IF NOT IN EXCESS OF PERMISSIBLE CONCENTRATIONS. CHRONIC:
NOT DETERMINED.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:NONE EXPECTED OTHER THAN POSSIBLE MINIMAL
IRRITATION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES: FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES.
SKIN: NONE CONSIDERED NECESSARY. INGEST: GET MD IMMED .
INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ART RESP) .
Fire Fighting
Flash Point Method:COC
Flash Point:355F,179C
Extinguishing Media:USE H*2O SPRAY, DRY CHEMICAL, FOAM OR CO*2. H*2O OR
FOAM MAY CAUSE FROTHING.
Fire Fighting Procedures:NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP . USE
H*2O TO COOL FIRE EXPOSE CNTNRS. IF LEAK OR SPILL NOT IGNIT USE
H*2O SPRAY TO DISPERSE VAPORS & (SUPP DATA)
Unusual Fire/Explosion Hazard:NONE
Accidental Release
Spill Release Procedures:CONTAIN SPILL IF POSSIBLE. WIPE UP OR ABSORB
ON SUITABLE MATERIAL AND SHOVEL UP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:MIN FEASIBLE HNDLG TEMPS SHOULD BE
MAINTAINED. PERIODS OF EXPOS TO HIGH TEMPS SHOULD BE MIN. H*2O
CONTAM SHOULD BE AVOIDED.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NONE REQUIRED IF EXPOSURES ARE WITHIN
PERMISSIBLE CONCENTRATIONS. NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NORMAL. CONSULT LOCAL/SAFETY HEALTH AUTHORITIES IF
ADDITIONAL GUIDANCE IS NECESSARY .
Protective Gloves:NONE SPECIFIED BY MANUFACTURER.
Eye Protection:CHEM WORKERS GOG,MAY ADD FULL(SUPP DATA)
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:REASONABLE PERSONAL CLEANLINESS:INCL CLEANSING
EXPOSED SKIN AREA SEVERAL TIMES DAILY W/SOAP & H*2O, LAUNDER(SUPP
DATA)
Supplemental Safety and Health
FIRE FIGHT PROC: TO PROVIDE PROT FOR PERSONS TRYING TO STOP LEAK. WASTE
DISP METH: MEET CRITERIA OF HAZ WASTE IF DISCARDED IN PURCHASED
FORM. DISP MUST BE I/A/W FED, STATE,& LOCAL REGS. HYGIENE PRAT: OR
DRY CLEAN SOILED WORK CLTHG ATLST WKLY. EYE PROT: LENGTH FACESHIELD
TO GOGGLES .
Chemical Properties
HCC:V6
Spec Gravity:0.9100
Appearance and Odor:PALE LIQUID.
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO, CO*2, ALDEHYDES AND KETONES,
COMBUSTION PRODUCTS OF NITROGEN AND SULFUR.
Disposal
Waste Disposal Methods:UNDER RCRA,THE RESPONSIBILITY OF USER OF PROD TO
DETERM WHETHER PROD MEETS RCRA CRITERIA FOR HAZ WASTE. PROD USES,
TRANSFORMATIONS, MIX, PROCESSES, ETC MAY RENDER RESULTING MATERIAL
HAZ. PROD HAS BEEN EVALUATED FOR RCRA CHARACT & DOES NOT(SUPP
DATA)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their