BNKLS - LITTON PN L2105-50 ALNICO MAGNETS

Product Identification

Product ID:LITTON PN L2105-50 ALNICO MAGNETS
MSDS Date:04/15/1989
FSC:5960
NIIN:01-040-4440
MSDS Number: BNKLS

Responsible Party
LITTON SYS INC/ELECTRONIC DEVICES DIV
960 INDUSTRIAL RD
SAN CARLOS, CA 94070-4116
US

Emergency Phone: (415) 591-8411

Info Phone: (415) 591-8411

Cage: MO696

Contractor
LITTON SYS INC/ELECTRONIC DEVICES DIV
SAN CARLOS, CA 94070-4116 US

Telephone: (415) 591-8411

Cage: MO696

Ingredients

ALUMINUM (POWDER)

CAS: 7429-90-5

RTECS: BD0330000

OSHA PEL 15 MG/CUM

ACGIH TLV: 10 MG/CUM (DUST)


NICKEL (SOLUBLE)

CAS: 7440-02-0

RTECS: QR5950000

OSHA PEL 1 MG/CUM

ACGIH TLV: 0.05 MG/CUM IC (A1)


COBALT

CAS: 7440-48-4

RTECS: GF8750000

OSHA PEL 0.1 MG/M3;AS CO

ACGIH TLV: 0.05 MG/M3;DUST 9293


COPPER (DUST & MIST), BRONZE POWDER

CAS: 7440-50-8

RTECS: GL5325000

OSHA PEL 0.1 MG(CU)/M3 (FUME)

ACGIH TLV: 0.2 MG/M3 (FUME)

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


TITANIUM DIOXIDE, TITANIUM(IV) OXIDE, TIO2

CAS: 13463-67-7

RTECS: XR2275000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


RED IRON OXIDE/IRON (III) OXIDE/FERRIC OXIDE/YELLOW FERRIC

CAS: 1309-37-1

RTECS: NO7400000

OSHA PEL 10 MG/M3 (FE)

ACGIH TLV: 5 MG/M3(FE),B2; 9293

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: UPPER RESPIRATORY TRACT
IRRITATION. SKIN: ALLERGIC REACTION
Explanation of Carcinogenicity:NICKEL IS A SUSPECTED (A1) HUMAN
CARCINOGEN.
Effects of Overexposure:INHALATION: UPPER RESPIRATORY TRACT IRRITATION.
SKIN: ALLERGIC REACTION.

First Aid

First Aid:OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Extinguishing Media:DRY NITROGEN OR ARGON OR SMOTHER W/DRY CHEMICAL
Fire Fighting Procedures:DON'T USE WATER OR HALON AGENTS ON FIRE.
POWDER MAY REIGNITE AFTER FIRES ARE EXTINGUISHED. BURNS RAPIDLY &
INTENSELY.
Unusual Fire/Explosion Hazard:FINE METAL POWDERS PRODUCED BY DRY
GRINDING/MACHINING MAY CAUSE EXPLOSION. DRY POWDER OR GRINDING
SLUDGE MAY IGNITE SPONTANEOUSLY IN AIR OR OXYGEN.

Handling

Handling and Storage Precautions:DON'T GRIND, CUT, FILE, SAW OR
OTHERWISE CREATE DUST FROM MAGNETIC MATERIAL USED AS A PART OF
MICROWAVE TUBES.
Other Precautions:MICROWAVE TUBES W/MAGNETIC MATERIAL HAVING A MAGNETIC
FIELD IN EXCESS OF 0.00525 GAUSS MEASURED AT 15 FT FROM ANY SURFACE
SHOULD NOT BE SHIPPED ON AIRCRAFT.

Exposure Controls

Respiratory Protection:IF >TLV, USE A NIOSH APPROVED RESPIRATOR.
Work Hygienic Practices:USE GOOD PERSONAL HYGIENE
Supplemental Safety and Health

Chemical Properties

Melt/Freeze Pt:M.P/F.P Text:2417F
Spec Gravity:7-8.5
Solubility in Water:INSOLUBLE
Appearance and Odor:METALLIC SILVER/LIGHT GREY METAL, ODORLESS.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS SUCH AS NITRIC ACID

Disposal

Waste Disposal Methods:RECYCLING OF MAGNETS USED IN MICROWAVE TUBES IS
RECOMMENDED. RETURN TO MANUFACTURER FOR RECYCLING, OTHERWISE
DISPOSE IN ACCORDANCE W/FEDERAL, STATE & LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.