BBLYF - FLEXSEAL LACQUER
- MSDS: BBLYF
- Manufacturer: AUSTENAL INC
- Product Name: FLEXSEAL LACQUER
- National Stock Number: 6520-00F002895
Product Identification
Product ID:FLEXSEAL LACQUER
MSDS Date:01/01/1987
FSC:6520
NIIN:00F002895
MSDS Number: BBLYF
Responsible Party
CHICAGO, IL 60632
US
Emergency Phone: 312-735-0601
Info Phone: 800-621-0381
Cage: 67532
Contractor
Telephone: 800-621-0381
Cage: 67532
Ingredients
ACETONE; DIMETHYL KETONE
CAS: 67-64-1
RTECS: AL3150000
Fraction By Weight: 40%
OSHA PEL 1000PPM
ACGIH TLV: 750PPM/1000STEL;9293
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ETHANOL (ETHYL ALCOHOL), TECSOL, ALCOHOL
CAS: 64-17-5
RTECS: KQ6300000
Fraction By Weight: 40%
OSHA PEL 1000 PPM
ACGIH TLV: 1000 PPM
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: RESPIRATORY TRACT
IRRITATION, HEADACHE, DIZZINESS, DROWSINESS. EYES: IRRITATION.
Explanation of Carcinogenicity:NONE
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR. SKIN: WASH THOROUGHLY W/SOAP
& WATER. EYES: FLUSH W/WATER FOR AT LEAST 15 MINS. OBTAIN MEDICAL
ATTENTION IN ALL CASES.
Fire Fighting
Flash Point Method:TCC
Flash Point:20C
Extinguishing Media:CO2 OR DRY CHEMICAL FOR SMALL FIRES.
Accidental Release
Spill Release Procedures:ELIMINATE ALL SOURCES OF IGNITION. COVER SPILL
WITH SAND AND TRANSFER TO CONTAINER FOR DISPOSAL.
Handling
Handling and Storage Precautions:DON'T HANDLE OR STORE NEAR FLAME OR
HEAT. ADEQUATE VENTILATION REQUIRED. KEEP CONTAINER CLOSED WHEN NOT
IN USE.
Exposure Controls
Respiratory Protection:N/K
_
Ventilation:ADEQUATE
Supplemental Safety and Health
PRODUCT HAS BEEN DISCONTINUED, BUT HAS BEEN REPLACED BY FLEXSEAL LIQUID
ADHESIVE, NSN NR: 652000F028179.
Chemical Properties
Boiling Pt:B.P. Text:153F
Spec Gravity:0.87
Solubility in Water:PARTIAL
Appearance and Odor:AMBER FLAMMABLE LIQUID; SHARP NON-RESIDUAL ODOR
Percent Volatiles by Volume:<81%
Stability
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:FLAME OR HEAT
Disposal
Waste Disposal Methods:DISPOSE OF MATERIAL IN APPROVED LANDFILL SITE.
CHECK STATE AND LOCAL EPA REGULATIONS BEFORE DISPOSAL.
======================================================================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.