BCBCG - GENESOLV DMC SOLVENT

  • MSDS: BCBCG
  • Manufacturer: ALLIED CHEMICAL CORP
  • Product Name: GENESOLV DMC SOLVENT
  • National Stock Number: 6850-00K000573
Product Identification

Product ID:GENESOLV DMC SOLVENT
MSDS Date:01/01/1985
FSC:6850
NIIN:00K000573
MSDS Number: BCBCG

Responsible Party
ALLIED CHEMICAL CORP.
COLUMBIA RD & PARK AVE
MORRISTOWN, NJ 07960
US

Cage: 1L168

Contractor
ALLIED-SIGNAL INC
1087R MORRISTOWN, NJ 07962-2332 US

Telephone: 201-455-4414

Cage: 1L164

Ingredients

METHYLENE CHLORIDE (SARA III)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 51.6%

OSHA PEL 500 PPM/C,1000; Z2

ACGIH TLV: 50 PPM, A2; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE (FREON 113) (SARA

CAS: 76-13-1

RTECS: KJ4000000

Fraction By Weight: 39.1%

OSHA PEL 1000PPM/1250STEL

ACGIH TLV: 1000PPM/1250STEL9192


CYCLOPENTANE

CAS: 287-92-3

RTECS: GY2390000

Fraction By Weight: 9.3%

OSHA PEL 600 PPM

ACGIH TLV: 600 PPM; 9192

Hazards

Effects of Overexposure:CNS DEPRESS,HIGH CONCS PROVOK CARDIAC
ARRYTHMIA,NAUS,HEADACHE,LITE HEADNES,CONFUSION,TINGLE OF SKIN.

First Aid

First Aid:INHALED:REMOVE TO FRESH AIR.GIVE CPR/OXYGEN IF NEED.DO NOT
GIVE ADRENALIN NOR ANY STIMULANT. EYES:FLUSH WITH LG AMTS
WATER.SKIN:FLUSH WITH WATER.IF SYMPTOMS PERSIST GET MEDICAL ATTN.

Fire Fighting

Extinguishing Media:PRESENCE IN FIRE DOES NOT HINDER USE OF ANY
STANDARD MEDIUM.
Fire Fighting Procedures:WEAR NIOSH APPRVD SELF-CNTND BRTHG APP.(SEE
SUPP DATA)
Unusual Fire/Explosion Hazard:WILL DECOMPOSE ABOVE 250F YIELDING
HALOGENS,CARBONYL HALIDES,INCLUDING PHOSGENE.AVOID HOT REACTV MET

Accidental Release

Spill Release Procedures:VVACATE AREA.STAY UPWIND.ALLOW TO EVAPORATE.IF
IGNITION SOURCES ARE PRESENT,BEWARE OF HAZARD DECOMPOSITION
PRODUCTS.

Handling

Handling and Storage Precautions:STORE IN COOL,WELL-VENTILATED ATEA OF
LOW FIRE HAZ.PROTECT FROM PHYSICAL DAMAGE.KEEP CONT.CLOSED.USE
FORMAL TANK ENTRY PROCED FOR CLEANING TANKS.
Other Precautions:MEDICAL SURVEILANCE/EMPLOYEE TRAINING
RECOMMENDE.AVOID INGESTION(METHANOL IS ACUTE AND CHRONIC
HAZARD.)TANKS CANNOT BE FLUSHED OF VAPOR IF SUMPS CONTAIN
LIQUID.HALOCARB REG WELL-VENTD DRAFT.

Exposure Controls

Respiratory Protection:SELF-CNTND BRTHG APP OR HOSE MASK.
Ventilation:MECHANICAL(GENERAL)ADEQUATE TO MAINTN PERMISABL EXPOS LIMIT
Protective Gloves:PVA/NEOPREN/NBR
Eye Protection:CHEM SAFETY GOGGLES
Other Protective Equipment:WHERE EXPOSD:FACE SHIELD,IMPERVIOUS CLOTHES
AND BOOTS.
Supplemental Safety and Health
SPECIAL FF PROCED;USE WATER SPRAY TO COOL EXPOSED CONTAINERS AND TO
KEEP SPILLAGE AWAY FROM FIRE AND HEAT.

Chemical Properties

HCC:T4
Boiling Pt:B.P. Text:97F/36.1C
Vapor Pres:460
Vapor Density:5.0
Spec Gravity:1.29
Evaporation Rate & Reference:1(ETHER=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS LIQUID,ETHEREAL ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
HOT REACTIVE METALS
Stability Condition to Avoid:WILL DECOMPOSE AT TEMPERATURES ABOVE 250F
Hazardous Decomposition Products:HALOGENS,CARBONYL HALIDES,INCLUDING
PHOSGENE

Disposal

Waste Disposal Methods:PERMIT TO EVAPORATE IN AIR OR RECOVER BY
REDISTILLATION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.