BCCKK - 13-GY-228 CATALYST,GRAY 26307,ISOCYANATE
- MSDS: BCCKK
- Manufacturer: DEFT CHEMICAL COATINGS
- Product Name: 13-GY-228 CATALYST,GRAY 26307,ISOCYANATE
- National Stock Number: 8010-00K001216
Product Identification
Product ID:13-GY-228 CATALYST,GRAY 26307,ISOCYANATE
MSDS Date:01/01/1985
FSC:8010
NIIN:00K001216
Kit Part:Y
MSDS Number: BCCKK
Responsible Party
IRVINE, CA 92714-6205
US
Cage: EO418
Contractor
Telephone: 949-474-0400
Cage: 33461
Ingredients
METHYL ETHYL KETONE (2-BUTANONE) (MEK) (SARA III)
CAS: 78-93-3
RTECS: EL6475000
Fraction By Weight: 45.0%
OSHA PEL 200 PPM/300 STEL
ACGIH TLV: 200 PPM/300STEL 9192
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
2-ETHOXYETHYL ACETATE (CELLOSOLVE ACETATE) (EGEEA)
CAS: 111-15-9
RTECS: KK8225000
Fraction By Weight: 10.0%
OSHA PEL S,100 PPM
ACGIH TLV: S, 5 PPM; 9192
METHYL ISOBUTYL KETONE (HEXONE) (SARA III)
CAS: 108-10-1
RTECS: SA9275000
Fraction By Weight: 10.0%
OSHA PEL 100 PPM
ACGIH TLV: 50 PPM/75 STEL; 9394
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
XYLENES (O-,M-,P- ISOMERS) (SARA III)
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: <5.0%
OSHA PEL 100 PPM/150 STEL
ACGIH TLV: 100 PPM/150STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
TOLUENE (SARA III)
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: <5.0%
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
Effects of Overexposure:SKIN/EYES:IRRITATION;INH:IRRIT OF RESP
TRACR/ACUTE NERVOUSSYSTEM DEPRESSION;HEADACHE,DIZZINESS,ETC.
First Aid
First Aid:EYES:FLUSH IMMED W/LG VOLUME OF WATER FOR AT LEAST 15 MIN.GET
MED ATTN;SKIN:WASH AFFECTED AREA W/WATER.REMOVE CONTAMINATED
CLOTHING.GET MED ATTN IF IRRIT OCCURS;INH:REMOVE FROM
EXPOSURE.RESTORE BREATH ING BY CPR,KEEP WARM & QUIET.GET MED ATTN.
Fire Fighting
Flash Point:20F(-6.6C)TCC
Lower Limits:UNK
Upper Limits:UNK
Extinguishing Media:CARBON DIOXIDE,FOAM OR DRY CHEM. (CLASS B FIRE
EXTINGUISHES)
Fire Fighting Procedures:SELF-CNTND BRTHG APP;WATER SPRAY TO COOL FIRE
EXPOSED CONTNR
Unusual Fire/Explosion Hazard:CLOSED CONTNRS MAY EXPLODE IN HEAT OF
FIRE;SPILL/RUNOFF MAY CAUSE POLLUTION,FIRE,&/OR EXPLSION HAZRD
Accidental Release
Spill Release Procedures:ELIM IGN SOURCES.VENTILATE AREA.USE PROTECTV
EQUIP.STOP LEAKW/O RISK.SM SPILL:CONTAIN/ROMOVE W/INERT ABSORBENT &
NON-SPARKING TOOLS.PLACE IN COVERD CONTNRS;LG SPILL:DIKE AREA &
PUMP LIQ TO SALVAGE TAN K.ABSORB REMAINING LIQ & SHOVEL UP
INTOCONTAINR.
Handling
Handling and Storage Precautions:STORE IN COOL,DRY WILL VENTILATED,LOW
FIRE RISK AREA.KEEP CLOSURE TIGHT & CONTNR UPRIGHT.STORE AWAY FM
IGNITION/HEAT SOURCES.PROTECT FM PHYSICAL DAMGE
Other Precautions:PREVENT PROLONGD/REPEATD BREATHING OF VAP OR SPRAY
MIST.CAN CAUSE ALLERGIC REACTION.FOLLOW SPECIAL PRECAUTIONS TO
APPLY ON HOT SURFACES.IF WATER IS USED FOR FIRE,FOG NOZZLES ARE
PREFERABLE.
Exposure Controls
Respiratory Protection:NIOSH APPROVED RESPIRATOR FOR
PAINT,LAQUER,ENAMEL MISTS/ORGANIC VAP.
Ventilation:ADEQUATE USING EXHAUS FAN OR IAW 29CFR.94
Protective Gloves:NEOPRENE/RUBBER
Eye Protection:SAFETY CLASS W/SIDE SHLD.
Other Protective Equipment:CLEAN,LONG SLEEVE/LONG LEG PROTECTIVE
CLOTHING.
Supplemental Safety and Health
MSDS FM MFR DATED:07/27/82: TWO PART RESIN MODIFIED POLYURETHANE
COATING: SEE P/N IND "B" FOR OTHER INGRED OF THIS ITEM: P/N IND "A"
IS FOR CATALYST BECAUSE MSDS FOR BASE NOT RECVD. KEY1:J1.
Chemical Properties
Boiling Pt:B.P. Text:175-313F
Vapor Density:>1.0
Spec Gravity:0.9023
Evaporation Rate & Reference:<1(SLWR THAN ETHR)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR THIN ORGANIC LIQ-ODOR OF MEK.
Percent Volatiles by Volume:76.4
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZING/CORR MATL;ALCOHOLS,AMINES;ISOCYANATE REACTNG COMPD
Stability Condition to Avoid:SOURCES OF IGNITION/HEAT SPARK,ETC,&
ELEVATED TEMPERATURES.
Hazardous Decomposition Products:CARBON MONO & DIOXIDE;OXIDES OF
NITROGEN.
Conditions to Avoid Polymerization:ELEVATED TEMPERTURES.
Disposal
Waste Disposal Methods:KEEP IN CLOSED CONTAINERS PENDING
DISPOSAL.DISPOSE ABSORBED LIQ/RESIDUE IN CLOSED CONTNRS BY SANITARY
LANDFILL;INCINERATE LIQ IN APPROVED FACILITY.DO NOT INCINERATE
CLOSED CONTAINERS. HANDLE/DISPOSE I N FULL COMPLIANCE W/ALL
FED,STATE,& LOCAL REGS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.