BCFNC - 541, COAGULANT

  • MSDS: BCFNC
  • Manufacturer: A R PRODUCTS
  • Product Name: 541, COAGULANT
  • National Stock Number: 9999-00N000464
Product Identification

Product ID:541, COAGULANT
MSDS Date:01/01/1985
FSC:9999
NIIN:00N000464
MSDS Number: BCFNC

Responsible Party
A-R PRODUCTS

Emergency Phone: 213-695-3008

Cage: OOOO1

Contractor
A-R PRODUCTS

Telephone: 213-695-3008

Cage: OOOO1

Ingredients

METHYL ALCOHOL (METHANOL) (SARA III)

CAS: 67-56-1

RTECS: PC1400000

Fraction By Weight: 5.0%

OSHA PEL S,200PPM/250STEL

ACGIH TLV: S,200PPM/250STEL; 93

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ETHYL ALCOHOL (ETHANOL)

CAS: 64-17-5

RTECS: KQ6300000

Fraction By Weight: 88.0%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM; 9192

Hazards

Effects of Overexposure:TOXIC BY METHANOL CONTENT. NOT POTABLE. IRRRIT
TO MUCOUS MEMBRANES.

Fire Fighting

Flash Point:50F TOC
Extinguishing Media:WATER, FOAM, CO*2
Unusual Fire/Explosion Hazard:FLAMMABLE LIQ

Accidental Release

Spill Release Procedures:FLUSH W/WATER. USE MASKS SUPPLIED W/FRESH AIR
TO ENTER AREA OF HIGH VAPOR CONC. KEEP SPARKS, FLAME AWAY.

Handling

Handling and Storage Precautions:KEEP AWAY FROM HEAT, FLAME. DO NOT
STORE IN DIRECT SUNLIGHT. KEEP CNTNRS CLOSED.
Other Precautions:USE EXPLOSION-PROOF ELECTRICAL EQUIP, NON-SPARKING
TOOLS. ELECTRICALLY BOND EQUIP.

Exposure Controls

Ventilation:LOCAL MECH EXH AT FLOOR LEVEL
Protective Gloves:REC
Eye Protection:REC
Supplemental Safety and Health
MFR ADDRESS: 8024 WESTERN AVE. WHITTER, CA 90606.

Chemical Properties

Vapor Pres:45
Vapor Density:1.60
Spec Gravity:1.020
Evaporation Rate & Reference:2.8, BUAC
Appearance and Odor:COLORLESS LIQ, CHARACTERISTIC ODOR

Stability

Stability Indicator/Materials to Avoid:YES
ALUMINUM
Hazardous Decomposition Products:ALDEHYDES, CARBON OXIDES

Disposal

Waste Disposal Methods:DO NOT ALLOW TO ENTER SEWERS WHERE VAPORS MAY
BECOME IGNITED. REMOVE & DISPOSE OF IAW LOCAL, STATE, FED REG.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.