BCTVR - 5L 100 SERIES PART A B COMBINED (OLD)
- MSDS: BCTVR
- Manufacturer: DYNALOY INC
- Product Name: 5L 100 SERIES PART A B COMBINED (OLD)
- National Stock Number: 8010-00N010736
Product Identification
Product ID:5L 100 SERIES PART A B COMBINED (OLD)
MSDS Date:09/01/1985
FSC:8010
NIIN:00N010736
MSDS Number: BCTVR
Responsible Party
HANOVER, NJ 07936
Emergency Phone: 201-877-9270
Info Phone: 201-877-9270
Cage: HO162
Contractor
Telephone: 317-788-9925;703-527-3887
Cage: 27908
Ingredients
EPOXY RESIN
CAS: 25068-38-6
Fraction By Weight: 20-25%
OSHA PEL OSHA PEL
ACGIH TLV: ACGIH TLV
POLYAMIDE LATENT EPOXY HARDNER
Fraction By Weight: 5-10%
OSHA PEL OSHA PEL
ACGIH TLV: ACGIH TLV
SILVER (SARA III)
CAS: 7440-22-4
RTECS: VW3500000
Fraction By Weight: 65-75%
OSHA PEL 0.01 MG/M3
ACGIH TLV: 0.1 MG/M3; 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
EPICHLOROHYDRIN (SARA III)
CAS: 106-89-8
RTECS: TX4900000
Fraction By Weight: Fraction by Wt
OSHA PEL S, 5 PPM
ACGIH TLV: S, 2 PPM; 9293
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
Hazards
LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:SEE SIGNS & SYMPTOMS OF OVEREXPOSURE.
Explanation of Carcinogenicity:EPOXY RESIN
EPICHLOROHYDRIN:IARC,PROBABLE HUMAN CARC,(GROUP 2B).NTP,ANTICIPATED
HUMAN CARC.
Effects of Overexposure:PROLONGED OR REPEATED
EXPOSURE:IRRITATION,SENSITIZATION,& DERMATITIS.DYNALOY SL IS
CONSIDERED A RELATIVELY SAFE ADHESIVE.
Medical Cond Aggravated by Exposure:
First Aid
First Aid:EYES:FLUSH WITH PLENTY OF POTABLE WATER FOR AT LEAST 15
MINUTES,THEN OBTAIN PROMPT MEDICAL ATTENTIONSKIN:WASH THOROUGHLY
WITH MILD SOAP & WATER.INGEST:DRINK WATER OR MILK,INDUCE
VOMITING,CALL MD IMMEDIATELY INHAL:REMOVE TO FRESH AIR.SUPPORT
BREATHING(GIVE O*2/ARTIFICIAL RESPIRATION)
Fire Fighting
Flash Point Method:CC
Flash Point:240C;464F
Extinguishing Media:FOAM,CO*2,OR DRY CHEMICAL.
Fire Fighting Procedures:USE SELF CONTAINED BREATHING APPARATUS
(MFR).USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:DECOMPOSITION AND COMBUSTION PRODUCTS MAY
BE TOXIC.
Accidental Release
Spill Release Procedures:AVOID SKIN CONTACT,TAKE UP WITH ABSORBENT
MATERIAL-WASH AREA WITH WATER.
Neutralizing Agent:
Handling
Handling and Storage Precautions:STORE REFRIGERATED,AVOID SKIN CONTACT.
Other Precautions:NONE
Exposure Controls
Respiratory Protection:USE NIOSH APPROVED RESPIRATOR IF NEEDED (MFR).
NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN
.
Ventilation:MECHANICAL:GOOD GENERAL VENTILATION.SPECIAL CURE,IN VENTED
OVEN.
Protective Gloves:RUBBER GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES.
Other Protective Equipment:BARRIER CREAM RECOMMENDED.
Work Hygienic Practices:THIS MIXTURE CONTAINS EPOXY RESIN & SHOULD BE
HANDLED W/ GOOD HOUSEKEEPING PROC NORM ASSOC W/ HANDLING EPOXY
RESINS.
Supplemental Safety and Health
DYNALOY 5L 100 SERIES PRODUCT SOLD IN JAN 1987 TO ZYMET INC,SEE PART B.
Chemical Properties
Boiling Pt:B.P. Text:285F;140C
Melt/Freeze Pt:M.P/F.P Text:N/K FP-N
Decomp Temp:Decomp Text:N/K FP-N
Vapor Pres:1
Vapor Density:8
Spec Gravity:2.6
pH:
Evaporation Rate & Reference:N/K FP-N
Solubility in Water:SLIGHT
Appearance and Odor:LOW ODOR,SILVER COLORED FLOWABLE PASTE
Percent Volatiles by Volume:
Corrosion Rate:
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS,MOISTURE,ACIDS,ALKALIES.
Stability Condition to Avoid:HEAT ABOVE 100 F.IN STORAGE.SMALL
QUANTITIES UNDER 100 GRAMS NOT AFFECTED.
Hazardous Decomposition Products:CO,CO*2,NITROGEN OXIDES.
Conditions to Avoid Polymerization:ELEVATED TEMP,MOISTURE,SMALL
QUANTITIES NOT EFFECTED.
Disposal
Waste Disposal Methods:INCINERATE BY APPROVED METHOD;CONTACT YOUR LOCAL
AUTHORITIES FOR SPECIFIC DETAILS(MFR). DISPOSAL MUST BE IN
ACCORDANCE WITH FEDERAL,STATE & LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.