BCXXM - PRIMER COATING, EPOXY 724600

Product Identification

Product ID:PRIMER COATING, EPOXY 724600
MSDS Date:02/17/1988
FSC:8010
NIIN:00-082-1714
Kit Part:Y
MSDS Number: BCXXM

Responsible Party
PRATT & LAMBERT,INC. - INDUSTRIAL COATINGS DIV.
16116 E 13TH ST
WICHITA, KS 67201
US

Cage: FO127

Contractor
PRATT AND LAMBERT INC
22 CLEVELAND, OH 44101-1027 US

Telephone: 216-566-2902

Cage: 61196

Ingredients

XYLENES (O-,M-,P- ISOMERS) (SARA III)

CAS: 1330-20-7

RTECS: ZE2100000

OSHA PEL 100 PPM/150 STEL

ACGIH TLV: 100 PPM/150STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


LEAD MONOXIDE (LEAD OXIDE YELLOW)

CAS: 1317-36-8

RTECS: OG1750000

OSHA PEL 0.05 MG/M3 (PB)

ACGIH TLV: 0.15 MG/M3(PB); 8990


SILICA, CRYSTALLINE - QUARTZ

CAS: 14808-60-7

RTECS: VV7330000

OSHA PEL SEE TABLE Z3

ACGIH TLV: 0.1 MG/M3 RDUST;9293


CHROMIUM (VI) OXIDE

CAS: 1333-82-0

RTECS: GB6650000

OSHA PEL C, 0.1 MG/M3 (CRO3)

ACGIH TLV: 0.05 MG/M3(CR); 8990


TALC (CONTAINING NO ASBESTOS)

CAS: 14807-96-6

RTECS: WW2710000

OSHA PEL 2 MG/M3 RDUST

ACGIH TLV: 2 MG/M3 RDUST; 9192


SILICA, AMORPHOUS, DUST

CAS: 112945-52-5

RTECS: VV7310000

OSHA PEL 6 MG/M3

ACGIH TLV: 10 MG/M3; 8990


N-BUTYL ALCOHOL (SARA III)

CAS: 71-36-3

RTECS: EO1400000

OSHA PEL 100 PPM

ACGIH TLV: S, C 50 PPM; 9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


N-BUTYL ACETATE (SARA III)

CAS: 123-86-4

RTECS: AF7350000

OSHA PEL 150 PPM/200 STEL

ACGIH TLV: 150 PPM/200STEL;9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


PROPYLENE GLYCOL METHYL ETHER ACETATE

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES
Health Hazards Acute and Chronic:REPEATED EXPOSURE TO CRYSTALLINE
SILICA MAY CAUSE PNEUMOCONIOSIS,A PROGRESSIVELY DISABLING LUNG
DISEASE.OVEREXPOSURE TO XYLENE MAY CAUSE INJURY TO THE LIVER,
KIDNEY & BLOOD.CHRONIC OVEREXPOSURE TO LEA D MAY RESULT IN SEVERE
DAMAGE TO BLOOD FORMING,NERVOUS,URINARY & REPRO SYSTEMS.REPEATED
CONTACT MAY CAUSE DERMATITIS.
Explanation of Carcinogenicity:CHROMIUM AND CERTAIN CHROMIUM COMPOUNDS
ARE LISTED AS POTENTIAL CARCINOGENS BY THE NTP AND THE IARC.
Effects of Overexposure:SWALLOW-GASTROINTESTINAL IRRITATION, NAUSEA AND
VOMITING. ASPIRATION OF MATERIAL INTO LUNGS CAN CAUSE CHEMICAL
PNEUMONITIS WHICH CAN BE FATAL.INHALE-NOSE & THROAT
IRRITATION.EYE-MAY CAUSE SEVERE EYE I RRITATION.SKIN-MAY CAUSE SKIN
SENSITIZATION AND SEVERE SKIN IRRITATION.
Medical Cond Aggravated by Exposure:PREEXISTING RESPIRATORY CONDITIONS
MAY BE AGGRAVATED BY EXPOSURE TO CRYSTALLINE SILICA.PREEXISTING
KIDNEY CONDITIONS BY EXPOSURE TO LEAD.

First Aid

First Aid:IF SWALLOWED, CALL POISON CONTROL CENTER, HOSPITAL EMERGENCY
ROOM OR MD IMMED.INHALED, REMOVE TO FRESH AIR IMMED. IF BREATHING
HAS STOPPED, GIVE ARTIFICIAL RESPIRATION. KEEP WARM AND QUIET. GET
MED AT TN IMMED. EYE, FLUSH WITH LARGE AMTS OFWATER AT LEAST 15
MIN. GET MED ATTN IMMED. SKIN, WASH AFFECTED AREA WITH SOAP &
WATER. REMOVE CONTAMINATED CLOTHING. GET MED ATTN IF IRRITATION
PERSISTS.

Fire Fighting

Flash Point:72F - 22C
Extinguishing Media:NFPA CLASS B FIRE EXTINGUISHER DESIGNED TO
EXTINGUISH FLAMMABLE LIQUID FIRES. POLYMER FOAM PREFERRED FOR LARGE
FIRES.
Fire Fighting Procedures:WEAR SELF CONTAINED BREATHING APPARATUS. WATER
MAY BE INEFFECTIVE, BUT MAY BE USED TO PREVENT PRESSURE BUILD-UP.
IF WATER IS USED, FOG NOZZLES ARE PREFERABLE.
Unusual Fire/Explosion Hazard:DURING EMERGENCY CONDITIONS, OVEREXPOSURE
TO DECOMPOSITION PRODUCTS MAY CAUSE A HEALTH HAZARD. OBTAIN MEDICAL
ATTENTION. WARNING! FLAMMABLE.

Accidental Release

Spill Release Procedures:KEEP SPECTATORS AWAY. ELIM ALL IGNITION
SOURCES. DIKE & CONTN SPILL WITH INERT MATL. TR LQDS TO COV MTL
CNTNR FOR RECOV OR DISP OR REM W/INERT ABSORB.USE NON-SPRKG TOOLS.
PLACE ABSORB MAT IN COV METAL CONTNR FOR DISP. PREVENT CONTAM OF
SEW, STRMS,ETC

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 90 DEGREES F.
Other Precautions:DO NOT TAKE INTERNALLY OR BREATH SANDING DUST. CLSE
CONTNR AFTER EA USE. KEEP AWAY FRM CHLDRN. AVD SKIN CONTCT. EMPTY
CONTNR MUST NOT BE WASHED & REUSED FOR ANY PURPOSE. NEVR USE
PRESSURE TO EMPTY. DO NOT WELD, BRAZE OR CUT ON EMPTY CONTNR.

Exposure Controls

Respiratory Protection:WELL-VENTILATED AREA-NIOSH APPROVED MECH FILTER
RESPIR TO REMOVE OVERSPRAY.RESTRICTED AREA-NIOSH APPROVED PAINT
SPRAY RESPIR.CONFINED AREA-NIOSH APPROVED AIR-SUPPLIED RESPIR. OSHA
STD 29CFR1910.1025 F OR SPECIFIC RESPIR PROTECT FOR LEAD.
Ventilation:PROVIDE GENERAL DILUTION AND LOCAL EXHAUST VENTILATION.
Protective Gloves:SOLVENT IMPERMEABLE GLOVES
Eye Protection:WEAR SAFETY SPECTACLES
Other Protective Equipment:EYEWASH FACILITY, SAFETY SHOWER
Supplemental Safety and Health
SOLVENT IMPERMEABLE GLOVES ARE REQUIRED FOR REPEATED OR PROLONGED
CONTACT PART A OF TWO PART PRODUCT SEE P/N IND BF OR PRT B KEY1:F3

Chemical Properties

HCC:F3
Boiling Pt:B.P. Text:212F - 293F
Vapor Pres:10
Vapor Density:>AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:59

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS OR ALKALINE MATERIALS. OXIDIZING MATERIALS. ACCELERATORS.
Stability Condition to Avoid:AVOID EXCESSIVE HEAT AND SOURCES OF
IGNITION. ALSO, THE ADDITION OF EXCESS HARDENER.
Hazardous Decomposition Products:BURNING,INCLUDING WHEN HEATED BY WELD
OR CUT,WILL PRODUCE SMOKE,CARBON MONOX & CARBON DIOX.ALSO OXIDES OF
CHROM & LEAD.
Conditions to Avoid Polymerization:KEEP AWAY FROM HEAT SPARKS AND
FLAME.

Disposal

Waste Disposal Methods:IAW FED, STATE & LOCAL LAWS. INCINERATE ONLY IN
EPA PERMITTED FACILITY. DO NOT INCINERATE CLOSED CONTAINERS.
OBSERVE PRECAUTIONS FOR DISPOSAL OF FLAMMABLE MATERIALS.
CONTAMINATED ABSORBANT MAY BE DISP OSED IN A HAZARDOUS WASTE
LANDFILL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.