BCXYP - POLYAMID, COMP II UO-082
- MSDS: BCXYP
- Manufacturer: CRAWFORD LABORATORIES INC
- Product Name: POLYAMID, COMP II UO-082
- National Stock Number: 8010-00-082-2440
Product Identification
Product ID:POLYAMID, COMP II UO-082
MSDS Date:10/20/1987
FSC:8010
NIIN:00-082-2440
Kit Part:Y
MSDS Number: BCXYP
Responsible Party
CHICAGO, IL 60609
US
Emergency Phone: 312-433-1307
Info Phone: 312-376-7132
Cage: DO165
Contractor
Telephone: 312-376-7132
Cage: 5V430
Ingredients
METHYL ETHYL KETONE (2-BUTANONE) (MEK) (SARA III)
CAS: 78-93-3
RTECS: EL6475000
Fraction By Weight: 20-50%
OSHA PEL 200 PPM/300 STEL
ACGIH TLV: 200 PPM/300STEL 9192
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ISOPROPYL ALCOHOL (SARA III)
CAS: 67-63-0
RTECS: NT8050000
Fraction By Weight: 20-50%
OSHA PEL 400 PPM/500 STEL
ACGIH TLV: 400 PPM/500STEL;9192
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Health Hazards Acute and Chronic:TOXICITY MAY CAUSE HEADACHE,
DIZZINESS, NAUSEA, AND LOSS OF CONSCIOUSNESS. EYE IRRITATION,
IRRITATED MUCOUS MEMBRANES, VOMITING DUE TO INGESTION, DEFATTING
AND DRYING OF THE SKIN.
Effects of Overexposure:OVEREXPOSURE MAY PRODUCE VARIOUS EFFECTS-ACUTE
TOXICITY, EYE IRRITATON, IRRITATED MUCOUS MEMBRANES, VOMITING, SKIN
IRRITATION & DERMATITIS.
First Aid
First Aid:DO NOT INDUCE VOMITING, EYE CONTACT-FLUSH EYES WITH WATER FOR
15 MINUTES, INHALATION-REMOVE VICTIM TO FRESH AIR AND PROVIDE
OXYGEN IF NECESSARY. KEEP VICTIM QUIET. SKIN CONTACT-FLUSH WITH
WATER-REMOVE CONTAMINATED CLOTHING, WASH WITH SOAP AND WATER. GET
MEDICAL ATTENTION IMMEDIATELY.
Fire Fighting
Flash Point Method:SCC
Flash Point:22F/-5.56C
Lower Limits:2.
Extinguishing Media:FOAM, CO2, OR DRY CHEMICAL
Fire Fighting Procedures:WATER MAY BE USED TO KEEP EXPOSED CONTAINERS
COOL AND TO KEEP FLAMMABLE STRUCTURES WET. DO NOT ENTER FIRE AREA
W/O PROPER PROTECTION.
Unusual Fire/Explosion Hazard:SEALED CONTAINERS MAY EXPLODE IF
OVERHEATED. WATER PRESSURE MAY SPREAD A FLAMMABLE LIQUID FIRE.
Accidental Release
Spill Release Procedures:ELIMINATE ALL IGNITION SOURCES. HANDLING
EQUIPMENT MUST BE GROUNDED TO PREVENT SPARKING. SOAK UP WITH AN
ABSORBENT AND PLACE IN NON-LEAKING CONTAINERS. SEAL TIGHTLY FOR
PROPER DISPOSAL.
Handling
Handling and Storage Precautions:TREAT AS A HAZARDOUS-FLAMMABLE
MATERIAL. KNOW APPLICABLE DOT REGULATIONS BEFORE ATTEMPTING TO
TRANSPORT THIS MATERIAL.
Exposure Controls
Respiratory Protection:MUST PROVIDE ADEQUATE VENTILATION TO KEEP VAPOR
CONCENTRATIONS BELOW ESTABLISHED TLV LIMIT. IN MORE CONFINED AREAS
A NIOSH-MSHA APPROVED RESPIRATOR EQUIPPED WITH ORGANIC VAPOR
CARTRIDGE SHOULD BE WORN
Ventilation:MUST PROVIDE ADEQUATE VENTILATION
Protective Gloves:RUBBER GLOVES
Eye Protection:APPROVED SAFETY GOGGLES AND FACESHIELD
Other Protective Equipment:HAVE EYE BATH AVAILABLE
Supplemental Safety and Health
Chemical Properties
Boiling Pt:B.P. Text:175-180F
Vapor Density:>AIR
Evaporation Rate & Reference:2.35 X N-BUTYL ACETATE
Appearance and Odor:CLEAR LIQUID
Percent Volatiles by Volume:78.6
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS AND STRONG ALKALIES.
Stability Condition to Avoid:AVOID HEAT, SPARKS, OPEN FLAMES AND
INCOMPATIBILITIES ABOVE HIGH TEMPERATURE, STRONG OXIDIZING
CONDITIONS.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION FOR PRODUCTS
LIKE THIS MAY GENERATE HIGHLY POISONOUS CARBON MONOXIDE AND OTHER
TOXIC GASES.
Disposal
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH CURRENT LOCAL, STATE
AND FEDERAL REGULATION. CONTACT AN APPROVED DISPOSAL FACILITY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.