BDHPM - CONOCO FLEET MOTOR OIL, GRADE 50

  • MSDS: BDHPM
  • Manufacturer: CONTINENTAL OIL CO
  • Product Name: CONOCO FLEET MOTOR OIL, GRADE 50
  • National Stock Number: 9150-00-188-9865
Product Identification

Product ID:CONOCO FLEET MOTOR OIL, GRADE 50
MSDS Date:01/01/1985
FSC:9150
NIIN:00-188-9865
MSDS Number: BDHPM

Responsible Party
CONTINENTAL OIL CO

Emergency Phone: 405-767-3456

Cage: KO523

Contractor
CONTINENTAL OIL CO.
1267 PONCA CITY, OK 74603 US

Telephone: 800-441-3637,CHEMTREC 800-424-9300

Cage: KO523

Ingredients

LUBRICATING OIL

Hazards

Effects of Overexposure:EXCESS INH OF MISTS/VAPORS: PULMONARY
DISORDERS. MAY CAUSE EYE IRRIT. SKIN IRRIT POSS.

First Aid

First Aid:EYE: IMMED FLUSH W/WATER AT LEAST 15 MIN, CALL MD. SKIN: WASH
THOROUGHLY W/SOAP & WATER. REMOVE CONTAM CLOTHING & WASH BEFORE
REUSE. GROSSLY CONTAM LEATHER SHOES SHOULD BE DISCARDED. INGEST: LG
AMTS, INDUCE VOMIT. CALL MD. INH: CALL MD!

Fire Fighting

Flash Point:390-440 COC
Extinguishing Media:WATER SPRAY, FOAM, CO*2, DRY CHEM
Fire Fighting Procedures:USE PROPER PROT EQUIP INCL SELF-CNTND BRTHNG
APPARATUS
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:CLEAN UP PROMPTLY BY ABSORPTION IN CLAY OR
EARTH

Handling

Handling and Storage Precautions:MAY BE STORED OUTDOORS OR INDOORS AWAY
FROM FURNACE OR OTHER HEATING EQUIP
Other Precautions:FOLLOW NEC PRECAUTIONS IAW NFPA CODE 30-1969 FOR
COMBUSTIBLE LIQ, CLASS IIIB

Exposure Controls

Respiratory Protection:NONE REQ
Ventilation:MECH, NORMAL SHOP VENT
Protective Gloves:NONE REQ
Eye Protection:NONE REQ
Supplemental Safety and Health
VAP PRESS: NIL. SPEC GRAV: 0.86-0.89. MFR STATES PROD NOT CONSIDERED TO
BE TOXIC ORALLY OR DERMALLY.

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:600F INIT
Evaporation Rate & Reference:NIL
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR BROWN VISCOUS LIQ, SLIGHT ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIAING MATLS, HEAT, FLAME
Hazardous Decomposition Products:NORMAL COMBUST: CO*2, WATER VAPOR.
INCOMP COMBUST: CO.

Disposal

Waste Disposal Methods:MFR SUGGESTS CONTROLLED INCINERATION, STORE FOR
PROFESSIONAL REMOVAL & DISPOSAL. AVOID DRAINAGE INTO SEWER. DISPOSE
IAW LOCAL, STATE, FED REG.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.