BGHZC - 02-GN-45 BASE,GREEN 34052,EPOXY-POLYAMID PR
- MSDS: BGHZC
- Manufacturer: DEFT CHEMICAL COATING
- Product Name: 02-GN-45 BASE,GREEN 34052,EPOXY-POLYAMID PR
- National Stock Number: 8010-01-050-4082
Product Identification
Product ID:02-GN-45 BASE,GREEN 34052,EPOXY-POLYAMID PR
MSDS Date:01/01/1985
FSC:8010
NIIN:01-050-4082
Kit Part:Y
MSDS Number: BGHZC
Responsible Party
IRVINE, CA 92714-6205
US
Emergency Phone: NONE PROVIDED
Cage: EO418
Contractor
Telephone: 949-474-0400
Cage: 33461
Ingredients
METHYL ETHYL KETONE (2-BUTANONE) (MEK) (SARA III)
CAS: 78-93-3
RTECS: EL6475000
Fraction By Weight: 15.0%
OSHA PEL 200 PPM/300 STEL
ACGIH TLV: 200 PPM/300STEL 9192
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
N-BUTYL ACETATE (SARA III)
CAS: 123-86-4
RTECS: AF7350000
Fraction By Weight: 15.0%
OSHA PEL 150 PPM/200 STEL
ACGIH TLV: 150 PPM/200STEL;9192
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
STRONTIUM CHROMATE (SARA III)
CAS: 7789-06-2
RTECS: GB3240000
Fraction By Weight: 15.0%
OSHA PEL 0.1 PPM CRO3;CEILING
ACGIH TLV: 0.0005MG CR/M3;A2;93
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
LEAD CHROMATE (OSHA PEL FOR LEAD FROM 29CFR
CAS: 7758-97-6
RTECS: GB2975000
Fraction By Weight: 5.0%
OSHA PEL 0.05 MG/M3 (PB)
ACGIH TLV: 0.05MG/M3(CR)A2;8990
TOLUENE (SARA III)
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 10.0%
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
Effects of Overexposure:SKIN/EYES:IRRITATION;INH:IRRIT OF RESP
TRACT/ACUTE NERVOUS SYSTEM DEPRESSION;HEADACHE,DIZZINESS,ETC.
First Aid
First Aid:EYES:IMMED FLUSH W/LG VOLUME OF WATER FOR AT LEAST 15 MIN.GET
MED ATTN;SKIN:WASH AFFECTED AREA W/WATER.REMOVE CONTAMINATED
CLOTHING.GET MED ATTN IF IRRIT OCCURS;INH:REMOVE FROM
EXPOSURE.RESTIORE BREAT HING BY CPR,KEEP WARM & QUIER.GET MED ATTN.
Fire Fighting
Flash Point:20F(-6.6C)-TCC
Lower Limits:UNK
Extinguishing Media:CARBON DIOXIDE,FOAM OR DRY CHEM.(CLASS B FIRE
EXTINGUISHER)
Fire Fighting Procedures:SELF-CNTND BRTHG APP;USE H*20 SPRAY TO COOL
FIRE EXPSD CNTNR
Unusual Fire/Explosion Hazard:CLOSD CONTNRS MAY EXPLODE IN HEAT OF
FIRE;SPILL/RUNOFF MAY CAUSE POLLUTION,FIRE,/OR EXPLOSION HAZARD
Accidental Release
Spill Release Procedures:ELIM IGN SOURCES.VENTILATE AREA.USE PROTECTV
EQUIP.STOP LEAK W/O RISK.SM SPILL:CONTAIN/REMOVE W/INERT ABSORBENT
& NON-SPARKING TOOLS.PLACE IN COVERED CONTNRS;LG SPILL:DIKE AREA &
PUMP LIQ TO SALVAGE T ANK.ABSORB REMAINING LIQ & SHOVEL UP INTO
CONTAINR
Handling
Handling and Storage Precautions:STORE IN COOL,DRY WELL VENTILATED,LOW
FIRE RISK AREA.KEEP CLOSURE TIGHY & CNTNR UPRIGHT.STORE AWAY FM
IGN/HEAT SOURCES.PROTECT FM PHYSICAL DAMAGE.
Other Precautions:PREVENT PROLONGED/REPEATD BREATHING OF VAP OR SPRAY
MIST.CAN CAUSE ALLERGIC REACTION.FOLLOW SPECIAL PRECAUTIONS TO
APPLY ON HOT SURFACES.IF WATER IS USED FOR FIRE,FOG NOZZLES ARE
PREFERABLE.
Exposure Controls
Respiratory Protection:NIOSH APPROVD RESP FOR PAINT,LAQUER,ENAMEL
MISTS,ORGANIC VAPORS,ETC.
Ventilation:ADEQUATE USING EXHAUST FAN OR LAW 29CFR PART 1910.94
Protective Gloves:NEOPRENE/RUBBER
Eye Protection:SAFETY GLASSESW/SIDE SHLD
Other Protective Equipment:CLEAN,LONG SLEEVE/LONG LEG PROTECTIVE
CLOTHING.
Supplemental Safety and Health
MSDS FM MFR DATE:01/13/82;TWO PART RESIN MODIFIED POLYURETHANE
COATING;THIS DATA DESCRIBES BASE;SEE P/N IND "B" FOR CATALYST;ALSO
CONTAINS 40% NON-AQUEOUS SOLN,HAZ UNK,UNIDENTIFIED.
Chemical Properties
HCC:F2
Boiling Pt:B.P. Text:175-260F
Vapor Density:>1.0
Spec Gravity:1.2833
Evaporation Rate & Reference:<1(SLWR THAN ETHR)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:GREEN COLORED PAINT
Percent Volatiles by Volume:58.4
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZING/CORROSIVE MATL,ACID & BASES.
Stability Condition to Avoid:SOURCE OF IGN,HEAT,SPARK,ETC.,& ELEVATED
TEMPERATURES
Hazardous Decomposition Products:CO*2,CO.
Conditions to Avoid Polymerization:ELEVATED TEMPERATURES.
Disposal
Waste Disposal Methods:KEEP IN CLOSED CONTAINERS PENDING
DISPOSAL.DISPOSE ABSORBED LIQ/RESIDUE IN CLOSED CONTNRS BY SANITARY
LANDFILL;INCINERATE LIQ IN APPROVED FACILITY.DO NOT INCINERATE
CLOSED CONTAINERS.HANDLE/DISPOSE IN FULL COMPLIANCE W/ALL
FED,STATE & LOCALREGS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.