BGXXB - KEM TRANSPORT ENML(LEAD):JK,J3,F1,33 SERIES
- MSDS: BGXXB
- Manufacturer: SHERWIN WILLIAMS COMPANY
- Product Name: KEM TRANSPORT ENML(LEAD):JK,J3,F1,33 SERIES
- National Stock Number: 8010-00N010339
Product Identification
Product ID:KEM TRANSPORT ENML(LEAD):JK,J3,F1,33 SERIES
MSDS Date:05/28/1985
FSC:8010
NIIN:00N010339
MSDS Number: BGXXB
Responsible Party
CLEVELAND, OH 44115
Emergency Phone: 216-566-2917
Info Phone: 216-566-2902
Cage: 54636
Contractor
Telephone: 800-251-2486/216-566-2242
Cage: 54636
Ingredients
INADEQUATE EVID FOR CARC
RTECS: 9999999ZZ
OSHA PEL N/K
ACGIH TLV: N/K
LEAD CHROMATE (OSHA PEL FOR LEAD FROM 29CFR
CAS: 7758-97-6
RTECS: GB2975000
Fraction By Weight: <30%
OSHA PEL 0.05 MG/M3 (PB)
ACGIH TLV: 0.05MG/M3(CR)A2;8990
LEAD (SARA III)
CAS: 7439-92-1
RTECS: OF7525000
Fraction By Weight: 0.3-18%
OSHA PEL 0.05 MG/M3;1910.1025
ACGIH TLV: 0.15 MG/M3;DUST 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
CHROMIUM ION (CR 6+)
CAS: 18540-29-9
RTECS: GB6262000
Fraction By Weight: 0.0-4.0%
OSHA PEL C, 0.1 MG/M3 (CRO3)
ACGIH TLV: 0.05 MG/M3 (CR);8990
CHROMIC YELLOW (LEAD CHROMATE).
CAS: 1344-37-2
Fraction By Weight: <30%
OSHA PEL N/K
ACGIH TLV: N/K
MOLYBDATE ORANGE.ACGIH TWA 1989.
CAS: 12656-85-8
RTECS: QA4660000
Fraction By Weight: <30%
OSHA PEL 5 MG(MO)/CUM TWA
ACGIH TLV: 5 MG(MO)/CUM TWA
XYLENES (O-,M-,P- ISOMERS) (SARA III)
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 1-30%
OSHA PEL 100 PPM/150 STEL
ACGIH TLV: 100 PPM/150STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
TOLUENE (SARA III)
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 0-5%
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
N-BUTYL ACETATE (SARA III)
CAS: 123-86-4
RTECS: AF7350000
Fraction By Weight: 0-5%
OSHA PEL 150 PPM/200 STEL
ACGIH TLV: 150 PPM/200STEL;9192
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
1.0.
CAS: 64742-47-8
Fraction By Weight: 15-35%
OSHA PEL N/K
ACGIH TLV: N/K
0.7.
CAS: 64742-95-6
Fraction By Weight: 0-20%
OSHA PEL N/K
ACGIH TLV: N/K
0.9.
CAS: 64742-48-9
Fraction By Weight: 5-15%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:N/K
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:REPORTS HAVE ASSOCIATED REPEATED AND
PROLONGED OVEREXPOSURE TO SOLVENTS WITH PERMANENT BRAIN AND NERVOUS
SYSTEM DAMAGE.REPEATED AND PROLONGED EXPOSURE TO SPRAY MIST MAY
CAUSE PERFORATION OF NASAL SEPT UM AND ULCERS OF THE SKIN.
Explanation of Carcinogenicity:LEAD CHROMATE:ACGIH A2:SUSP HUM CARC
(1989).HEXAVALENT CR CPDS:SUFF EVID FOR CARC IN HUM & ANIM (IARC
1987).CR (SEE SUP)
Effects of Overexposure:EYES:N/K .SKIN:IRRITANT.RPTD/PRLNGD EXPOS TO
SPRAY MIST MAY CAUSE SKIN ULCERS.INGEST:N/K .INHAL:IRRIT TO UPPER
RESP SYSTEM.IN CONFINED AREA VAP IN HIGH CONC ARE ANESTHETIC.OVEREX
POS MAY RESULT IN LIGHTHEAD & STAG GAIT.REPEATED & PROLONGED EXPOS
TO SPRAY MISTMAY CAUSE PERFORATION OF NASAL SEPTUM.
Medical Cond Aggravated by Exposure:N/K
First Aid
First Aid:EYES:FLUSH WITH LARGE AMOUNTS OF WATER FOR 15 MIN.GET MEDICAL
ATTN.SKIN:WASH AFFECTED AREA THOROUGHLY WITH SOAP & WATER.REMOVE
CONTAMINATED CLOTHING & LAUNDER BEFORE RE-USE.INGESTION:CALL MD
IMMED (FP N).INHALATION:IF AFFECTED,REMOVE FROM EXPOSURE.RESTORE
BREATHING.KEEP WARM AND QUIET.
Fire Fighting
Flash Point Method:PMCC
Flash Point:72F,22.22C
Lower Limits:N/K
Upper Limits:0.7
Extinguishing Media:CARBON DIOXIDE,DRY CHEMICAL,FOAM.WATER SPRAY MAY BE
INEFFECTIVE.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
.IF USE H*2O,FOG NOZZ PREF.MAY USE H*2O TO COOL CLSD CONTRS TO PVNT
PRESS BUILD-UP & POSS AUTOIGNIT OR EXPLO.
Unusual Fire/Explosion Hazard:KEEP CONTRS TIGHTLY CLSD.ISOLATE FROM
HEAT,ELEC EQUIP,SPARKS & OPEN FLAME.CLSD CONTRS MAY EXPLO IF EXPOS
TO EXTREME HEAT.APPLICATION TO HOT SURFACE (SEE SUPP)
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION.VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:N/K
Handling
Handling and Storage Precautions:FLAMM.AVOID HEAT.ELIM ALL SOURCES OF
IGNIT.VENT AREA DURING & AFTER USE TO ELIM ALL VAP.CONSULT NFPA
CODE.USE APPRVD BONDING/GROUNDING PROC.(SEE SUPP)
Other Precautions:COATING CONTAINS MATERIALS CLASSIFIED AS NUIS
PARTICULATES AT POSS HAZ LEVELS DURING SANDING/ABRADING OF DRIED
MATL.CONTAINS LEAD.DO NOT APPLY TO ANY SURFACE TO BE IN CONTACT W/
CHILDREN.DELIB CONC & INHAL OF PROD CAN BE HARMFUL OR FATAL.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL AND GENERAL VENTILATION NECESSARY TO KEEP AIR
CONCENTRATION BELOW TLV .
Protective Gloves:AS RECOMMENDED BY GLOVE SUPPLIER.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:N/K
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
EXPLO HAZ:REQ SPEC PREC.OVEREXPOS TO DECOMP PROD (CO*2,CO,METAL OXIDES)
POSS HLTH HAZ.SYMP MAY NOT BE IMMED SEEN.GET MED ATTN.HNDLG/STOR
PREC:KEEP CONTR CLSD.TRANSFER ONLY TO APPRVD CONTR W/ PROPER LB
LNG.AVOID INGESTING & CONTACT W/ CHILD.EXPLAN OF CARC:& CERTAIN CR
CPDS.KNOWN HUM CARC (NTP 1985).(SEE ING 12)
Chemical Properties
Boiling Pt:B.P. Text:222-395F
Melt/Freeze Pt:M.P/F.P Text:N/K
Decomp Temp:Decomp Text:N/K
Vapor Pres:N/K
Vapor Density:>1 (AIR=1)
Spec Gravity:0.93-1.2,H*2O=1
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:N/K
Appearance and Odor:N/K
Percent Volatiles by Volume:59-65
Stability
Stability Indicator/Materials to Avoid:YES
METALLICS CONTAIN AL.CONTAM W/ H*2O,ACIDS OR ALKALIS CAN CAUSE
EVOLUTION OF H,CAUSING DANGEROUS INC PRESS IN CLSD CONTR.
Stability Condition to Avoid:N/K
Hazardous Decomposition Products:CARBON DIOXIDE,CARBON MONOXIDE,OXIDES
OF LEAD,CHROMIUM,MOLYBDENUM.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE AND LOCAL REGULATIONS .INCINERATE IN APPROVED
FACILITY.DO NOT INCINERATE CLOSED CONTAINER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.