BGYGX - TECH BEAD BREAKER

Product Identification

Product ID:TECH BEAD BREAKER
MSDS Date:10/01/1985
FSC:6850
NIIN:00F008576
MSDS Number: BGYGX

Responsible Party
TECHNICAL RUBBER COMPANY, INC.
200 EAST COSHOCTON STREET
JOHNSTOWN, OH 43031

Emergency Phone: (800) 433-8324

Info Phone: (614) 967-9015

Cage: 5U567

Contractor
TECHNICAL RUBBER COMPANY
486 JOHNSTOWN, OH 43031-1041 US

Telephone: 740-967-9015; 800-433-8324

Cage: 5U567

Ingredients

AROMATIC HYDROCARBON SOLVENT NAPTHA

CAS: 64742-94-5

Fraction By Weight: 10-30%

OSHA PEL 210 PPM

ACGIH TLV: 210 PPM


XYLENES (O-,M-,P- ISOMERS) (SARA III)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: >60%

OSHA PEL 100 PPM/150 STEL

ACGIH TLV: 100 PPM/150STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE: SEVERE IRRITATION, REDNESS,
TEARING, BLURRED VISION. SKIN: IRRITATION, DEFATTING, DERMATITIS.
INHALATION: NASAL/RESPIRATORY IRRITATION, DIZZINESS, WEAKNESS,
FATIGUE, NAUSEA, HEADACHE, POSSIBLE UN CONSCIOUSNESS &
ASPHYXIATION. INGESTION: GASTROINTESTINAL IRRITATION, NAUSEA,
VOMITING & DIARRHEA.
Explanation of Carcinogenicity:THE NATIONAL CANCER INSTITUTE HAS
CONCLUDED FROM THE RESULTS OF A BIOASSAY THAT PERCHLOROETHYLENE IS
A LIVER CARCINOGEN.
Effects of Overexposure:OVEREXPOSURE TO COMPONENT CAN RAISE THE LEVEL
OF CARBON MONOXIDE IN THE BLOOD CAUSING CARDIOVASCULAR STRESS.
INHALATION: CARDIAC ABNORMALITY, LIVER ABNORMALITIES, KIDNEY, LUNG,
BRAIN, SPLEEN & EYE DAM AGE, ANEMIA. ASPIRATION OF MATERIAL INTO
THE LUNGS CAN CAUSE CHEMICAL PNEUMONITIS WHICH CAN BE FATAL.
Medical Cond Aggravated by Exposure:EPINEPHRINE/EPHEDRINE MAY ADVERSELY
AFFECT THE HEART WITH FATAL RESULTS.

First Aid

First Aid:SKIN: WASH W/SOAP & WATER. REMOVE/LAUNDER CONTAMINATED
CLOTHING BEFORE REUSE. EYE: FLUSH W/WATER. GET MED ATT. INGESTION:
DON'T INDUCE VOMITING, KEEP PERSON WARM, QUIET/GET MED ATT.
INHALATION: MOVE T O FRESH AIR. IF BREATHING IS
DIFFICULT.ADMINISTER OXYGEN. IF BREATHING HAS STOPPED GIVE
ARTIFICIAL RESPIRATION. KEEP PERSON WARM, QUIET & GET MED ATT.
DON'T GIVE STIMULANTS.

Fire Fighting

Flash Point:>200F
Extinguishing Media:REGULAR FOAM, WATER FOG, CO2, DRY CHEMICAL
Fire Fighting Procedures:WEAR SCBA W/A FULL FACEPIECE OPERATED IN
PRESSURE-DEMAND. VAPORS ARE >AIR. MAY TRAVEL ALONG THE GROUND/BE
MOVED BY VENTILATION/IGNITED BY FLAMES.
Unusual Fire/Explosion Hazard:NEVER USE WELDING OR CUTTING TORCH ON OR
NEAR DRUM (EVEN EMPTY) BECAUSE PRODUCT (EVEN JUST RESIDUE) CAN
IGNITE EXPLOSIVELY.

Accidental Release

Spill Release Procedures:ABSORB ON ABSORBENT MATERIAL/TRANSFER TO HOOD.
ELIMINATE IGNITION SOURCES (FLAMES/SPARKS). STOP SPILL AT SOURCE,
DIKE AREA OF SPILL TO PREVENT SPREADING, PUMP LIQUID TO SALVAGE
TANK. LIQUID MAY BE TAK EN UP ON SAND/EARTH/CLAY/SHOVELED INTO
CONTAINERS.

Handling

Handling and Storage Precautions:CONTAINERS OF THIS MATERIAL MAY BE
HAZARDOUS WHEN EMPTIED. SINCE EMPTIED CONTAINERS RETAIN PRODUCT
RESIDUES (VAPOR, LIQUID & SOLIDS).

Exposure Controls

Respiratory Protection:IF TLV IS EXCEEDED, A NIOSH/MSHA JOINTLY
APPROVED AIR SUPPLIED RESPIRATOR IS ADVISED. OSHA REGULATIONS ALSO
PERMIT OTHER NIOSH/MSHA RESPIRATORS UNDER SPECIFIED CONDITIONS.
Ventilation:PROVIDE SUFFICIENT MECHANICAL/LOCAL EXHAUST VENTILATION TO
KEEP Protective Gloves:RESISTANT
Eye Protection:GOGGLES, SAFETY GLASSES
Other Protective Equipment:POLYVINYL ALCOHOL & NITRILE RUBBER GLOVES,
IMPERVIOUS CLOTHING, BOOTS
Supplemental Safety and Health

Chemical Properties

Boiling Pt:B.P. Text:102.90F
Vapor Pres:68.00F
Vapor Density:>AIR
Spec Gravity:>WATER
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:100%
Percent Volatiles by Volume:100%

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS

Disposal

Waste Disposal Methods:ALLOW VOLATILE PORTIONS TO EVAPORATE IN
HOOD/SUFFICIENT TIME FOR VAPORS TO CLEAR HOOD DUCT WORK, DESTROY BY
LIQUID INCINERATION W/OFF-GAS SCRUBBED. CONTAMINATED ABSORBENT MAY
BE DEPOSITED IN A LANDFIL L IN ACCORDANCE W/LOCAL/STATE/FEDERAL
REGULATIIONS

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.