Product Identification

Product ID:ENAMEL ALKYD SG RED 21136
MSDS Date:02/11/1988
FSC:8010
NIIN:00-087-0102
MSDS Number: BHXDG

Responsible Party
PRATT & LAMBERT, INC., INDUSTRIAL COATINGS DIV.
WICHITA, KS 67201
US

Emergency Phone: 316-733-1361

Info Phone: 316-733-1361

Preparer: W.A. ELLISON, OPNS MGR

Cage: FO127

Contractor
PRATT AND LAMBERT INC
22 CLEVELAND, OH 44101-1027 US

Telephone: 216-566-2902

Cage: 61196

Ingredients

VM&P NAPHTHA (LIGROINE)

CAS: 8032-32-4

RTECS: OI6180000

OSHA PEL 300 PPM/400 STEL

ACGIH TLV: 300 PPM; 9192


TITANIUM DIOXIDE

CAS: 13463-67-7

RTECS: XR2275000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


TALC (CONTAINING NO ASBESTOS)

CAS: 14807-96-6

RTECS: WW2710000

OSHA PEL 2 MG/M3 RDUST

ACGIH TLV: 2 MG/M3 RDUST; 9192


SILICA, CRYSTALLINE - CRISTOBALITE

CAS: 14464-46-1

RTECS: VV7325000

OSHA PEL SEE TABLE Z3

ACGIH TLV: 0.05 MG/M3 RDUST9293


MINERAL SPIRITS (VAPOR PRESSURE 2 MMHG @ 20 DEG. C)

CAS: 64475-85-0

RTECS: PY8240000

OSHA PEL 500 PPM/2950 MG/CU.M

ACGIH TLV: 100 PPM/525 MG/CU.M.


VOC. 3.8 LB/GL LESS WATER & NPRS* 456 G/L LESS WATER

RTECS: 9999999VO


VOC. 9.3 LB/GAL SOLIDS APPLIED 1116 G/L SOLIDS CALCULATED

RTECS: 9999999VO

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:REPEATED EXPOSURE TO CRYSTALLINE
SILICA MAY CAUSE PNEUMOCONIOSIS, PROGRESSIVE DISABLING LUNG
DISEASE. REPORTS ASSOCIATE PROLONGED/REPEATED OCCUPATIONAL
OVEREXPOSURE TO SOLVENTS WITH PERMANENT BRAIN & NERVOUS SYSTEM
DAMAGE. INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING/INHALING
OF CONTENTS MAY BE HARMFUL EVEN FATAL.
Explanation of Carcinogenicity:AT THE TLV THE TIO2 MANUFACTURER
CONCLUDES THAT THERE IS NO SIGNIFICANT HAZARD FOR MAN.
Effects of Overexposure:INGESTION:CAN CAUSE GASTROINTESTINAL IRRIT,
NAUSEA, VOMITING. ASPIRATION OF MATERIAL INTO LUNGS, MAY CAUSE CHEM
PNEUMONITIS, CAN BE FATAL. INHALED:NOSE OR THROAT IRRIT. HIGH
CONCENTRATE-ACUTE CENTRAL NERV SYS DEPRESSION;HEADACHES,
DIZZINESS, NAUSEA & CONFUSION. EYES: MAY CAUSE IRRIT. SKIN: MAY
CAUSE DEFATTING & IRRIT.
Medical Cond Aggravated by Exposure:PREXISTING RESPIRATORY CONDITIONS
MAY BE AGGRAVATED BY EXPOSURE TO CRYSTALLINE SILICA.

First Aid

First Aid:INGEST:DO NOT INDUCE VOMIT.CALL PCC/HOSPITAL/PHYSICIAN
IMMED.INHALED:REMOVE TO FRESH AIR IMMED.BREATH STOPPED, GIVE
CPR.KEEP WARM & QUIET.GET MED ATTN IMMED.EYES:FLUSH W/LRG AMT OF
WATER,LIFTING LIDS FOR AT LEAST 15 MIN.GET MED ATTN.SKIN:REMOVE
CONTAM CLOTHES.WASH W/SOAP & WATER. OBTAIN MED ATTN IF IRRIT
PERSIST.NOTE TO PHYSICIAN:TREATMENT SHOULD BE DIRECTED TO CONTROL
OF SYMPT/CLINICAL CONDITIONS

Fire Fighting

Flash Point Method:SCC
Flash Point:>102 F/39 C
Extinguishing Media:USE NFPA CLASS B FIRE EXTINGUISHERS FOR FLAMMABLE
LIQUID FIRES. POLYMER FOAM IS PREFERRED FOR LARGE FIRES.
Fire Fighting Procedures:WEAR SCBA. WATER MAY BE INEFFECTIVE, USED TO
COOL CONTAINERS TO PREVENT PRESSURE BUILD-UP/AUTO-IGNITE/EXPLOSION
FROM EXTREME HEAT.FOG NOZZLES PREFERRED W/WATER
Unusual Fire/Explosion Hazard:IN EMERG CONDITIONS, OVEREXPOSURE TO
DECOMP PRODUCTS MAY CAUSE DELAYED HEALTH HAZARDS, OBTAIN MED ATTN.
KEEP CONTAINERS TIGHTLY CLOSED. ISOLATE FROM HEAT, *

Accidental Release

Spill Release Procedures:KEEP SPECTATORS AWAY. ELIM ALL IGNITE
SOURCES(FLAME,HOT SURFACES,SOURCES ELEC,STATIC,FRICTION
SPARKS).DIKE & CONTAIN W/INERT MATERIAL(E.G.SAND,EARTH).TRANSFER
LIQ TO COVER METAL CONTAINER FOR RECOVERY /DISPOSAL. PREVENT
CONTAMINATION OF SEWERS, **
Neutralizing Agent:N/K. **STREAMS & GROUNDWATERS WITH SPILLED MATERIAL
OR USED ABSORBANT.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 95 DEG F. STORE
LARGE AMOUNTS IN COMPLIANCE WITH OSHA 29CFR1910.106. CLOSE
CONTAINERS AFTER EACH USE.DO NOT TAKE INTERNALLY.
Other Precautions:EMPTY CONTAINERS MUST NOT BE WASHED & RE-USED FOR ANY
PURPOSE. CONTAINERS SHOULD BE GROUNDED & BONDED TO THE RECEIVING
CONTAINER. DO NOT WELD, BRAZE OR CUT ON EMPTY CONTAINERS. NEVER USE
PRESSURE TO E MPTY. DRUM IS NOT A PRESSURE VESSEL.

Exposure Controls

Respiratory Protection:WHEN SPRAYING OUTDOORS OR IN OPEN OR
WELL-VENTILATED AREA, USE NIOSH MECH FILTER RESPIRATORS TO REMOVE
OVERSPRAY. IN RESTRICTED VENTILATION AREA, USE NIOSH PAINT SPRAY
(COMBINATION CHEM CARTRIDGE/MECH FILTER) RESPIRATOR TO REMOVE
SPRAY MIST
Ventilation:GENERAL DILUTION/LOCAL EXHAUST IN VOL/PATTERN TO KEEP
CONCENTRATE OF HAZARD INGRED BELOW TLV/LEL & REMOVE DECOMP PRODUCT
Protective Gloves:IMPERMEABLE GLOVES-REPEATED/PROLONG USE
Eye Protection:WEAR SAFETY SPECTACLES
Other Protective Equipment:NOT LIKELY TO BE NEEDED.
Work Hygienic Practices:ALLOWABLE EXPOSURE LEVEL SHOULD NOT BE EXCEEDED
FOR ANY TIME PERIOD.
Supplemental Safety and Health
THIS PRODUCT, IF DISCARDED DIRECTLY, WOULD BE CLASSIFIED A HAZARDOUS
WASTE BASED ON ITS IGNITABILITY CHARACTERISTIC, I.E. HAS A FLASH
POINT OF 140 DEGREES F. OR LESS. THE PROPER RCRA CLASSIFICATION WO
ULD BE DOO1.

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:280 TO 388F
Vapor Density:> THAN AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:58

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS OR ALKALINE MATERIALS.
Stability Condition to Avoid:AVOID EXCESSIVE HEAT & SOURCES OF IGNITE.
* ELECTRIC EQUIPMENT, SPARKS & FLAME. CLOSED CONTAINER MAY EXPLODE
FROM HEAT.
Hazardous Decomposition Products:BURNING, INCLUDING WHEN HEATED BY
WELDING OR CUTTING, WILL PRODUCE SMOKE, CARBON MONOXIDE AND CARBON
DIOXIDE.
Conditions to Avoid Polymerization:KEEP AWAY FROM HEAT, SPARKS AND
FLAME.

Disposal

Waste Disposal Methods:INCINERATE ONLY EPA PERMITTED FACILITY. DON'T
INCINERATE CLOSED CONTAINER. OBSERVE PRECAUTIONS FOR DISPOSAL OF
FLAMMABLE MATERIALS. CONTAM ABSORB MAY BE DISPOSED IN A HAZARDOUS
WASTE LANDFILL. DISPOSE ONLY IN ACCORDANCE W/FEDERAL, STATE &
LOCAL REGS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.