BJCMR - 7312 CONOCO DECTOL R.O. OIL 150

  • MSDS: BJCMR
  • Manufacturer: CONOCO INC
  • Product Name: 7312 CONOCO DECTOL R.O. OIL 150
  • National Stock Number: 9150-00F012435
Product Identification

Product ID:7312 CONOCO DECTOL R.O. OIL 150
MSDS Date:01/01/1989
FSC:9150
NIIN:00F012435
MSDS Number: BJCMR

Responsible Party
CONOCO INC
5 GREENWAY PLAZA E
HOUSTON, TX 77252-5000
US

Emergency Phone: 800-441-3637/713-293-5550

Info Phone: 713-293-5550/800-441-3637

Cage: 5R396

Contractor
CONOCO INC
2197 HOUSTON, TX 77252 US

Telephone: 713-293-5550PRODUCT/ 800-4413637MED

Cage: 5R396

Ingredients

DEODORIZED KEROSENE, DEOBASE

CAS: 8020-83-5

RTECS: HF9500000


PETROLEUM DISTILLATE, PETROLEUM OIL, BASE OIL

CAS: 8002-05-9

RTECS: SE7175000

OSHA PEL 5 MG/CUM MIST

ACGIH TLV: 5 MG/CUM MIST

Hazards

Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN: PROLONGED/REPEATED EXPOSURE MAY
CAUSE MINOR IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION.

First Aid

First Aid:EYES: IMMEDIATLEY FLUSH W/PLENTY OF WATER FOR 15 MINS. SKIN:
IMMEDIATELY WASH W/SOAP & PLENTY OF WATER. INHALATION: REMOVE TO
FRESH AIR. GIVE CPR/OXYGEN IF NEEDED. INGESTION: DON'T INDUCE
VOMITING. GI VE LARGE QUANTITIES OF WATER. NEVER GIVE ANYTHING BY
MOUTH TO AN UNCONSCIOUS PERSON. OBTAIN MEDICAL ATTENTION IN ALL
CASES. (SEE SUPP)

Fire Fighting

Flash Point Method:PMCC
Flash Point:390F
Extinguishing Media:WATER SPRAY, DRY CHEMICAL, FOAM, CO2
Fire Fighting Procedures:WATER/FOAM MAY CAUSE FROTHING. USE WATER TO
KEEP FIRE-EXPOSED CONTAINERS COOL. WATER SPRAY MAY BE USED TO FLUSH
SPILLS AWAY FROM EXPOSURES.
Unusual Fire/Explosion Hazard:PRODUCTS OF COMBUSTION MAY CONTAIN CO,
CO2 & OTHER TOXIC MATERIALS.

Accidental Release

Spill Release Procedures:CONTAIN AREA IMMEDIATELY. RECOVER AS PRODUCT
BY METHODS AS VACUUMING, FOLLOWED BY RECOVERING RESIDUAL FLUIDS BY
USING ABSORBENT MATERIALS. AVOID WASHING, DRAINING/DIRECTING
MATERIAL TO STORM/SANITARY SEWERS.

Handling

Handling and Storage Precautions:STORE IAW/NATIONAL FIRE PROTECTION
ASSOCIATION REGULATIONS.
Other Precautions:DON'T ENTER ENCLOSED/CONFINED SPACE W/O PROPER
PROTECTIVE EQUIPMENT. REVIEW FIRE & EXPLOSION HAZARDS BEFORE
PROCEEDING W/CLEAN UP. USE APPROPRIATE PERSONAL PROTECTIVE
EQUIPMENT DURING CLEAN UP.

Exposure Controls

Respiratory Protection:NONE REQUIRED
Ventilation:NORMAL SHOP VENTILATION
Protective Gloves:NITRILE BUTYL RUBBER/NEOPRENE
Eye Protection:REQUIRED
Other Protective Equipment:SAFETY GLASSES W/SIDE SHIELDS, CHEMICAL
SPLASH GOGGLES, COVERALLS W/LONG SLEEVES.
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
NOTES TO PHYSICIAN: GASTIC LAVAGE BY QUALIFIED MEDICAL PERSONNEL MAY BE
CONSIDERED, DEPENDING ON QUANTITY OF MATERIAL INGESTED.

Chemical Properties

Boiling Pt:B.P. Text:780-1200F
Vapor Pres:0
Vapor Density:>1
Spec Gravity:0.89
Evaporation Rate & Reference:0
Solubility in Water:INSOLUBLE
Appearance and Odor:LIGHT BROWN LIQUID W/MILD PETROLEUM HYDROCARBON
ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING MATERIALS
Stability Condition to Avoid:HEAT, FLAME
Hazardous Decomposition Products:HAZARDOUS GASES/VAPORS, CO2, CO

Disposal

Waste Disposal Methods:RECYCLE AS MUCH OF THE RECOVERABLE PRODUCT AS
POSSIBLE. TREATMENT, STORAGE, TRANSPORATION & DISPOSAL MUST BE
IAW/FEDERAL, STATE & LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.