BJZGM - DESICCITE 25, ACTIVATED DESICCANT
- MSDS: BJZGM
- Manufacturer: ENGELHARD CORP
- Product Name: DESICCITE 25, ACTIVATED DESICCANT
- National Stock Number: 6850-00-935-9797
Product Identification
Product ID:DESICCITE 25, ACTIVATED DESICCANT
MSDS Date:05/19/1995
FSC:6850
NIIN:00-935-9797
MSDS Number: BJZGM
Responsible Party
SOLON, OH 44139
US
Emergency Phone: 216-349-7300
Info Phone: 216-349-7300
Cage: 0FDV7
Contractor
Telephone: 216-349-7300
Cage: 0FDV7
Ingredients
SILICA, CRYSTALLINE - QUARTZ
CAS: 14808-60-7
RTECS: VV7330000
Fraction By Weight: 1-3% %
OSHA PEL SEE TABLE Z3
ACGIH TLV: 0.1 MG/M3 RDUST;9293
CLAY/MICRO-CELL
CAS: 12141-46-7
Fraction By Weight: 97-99% %
BENTONITE (INCLUDES INGRED # 1 & 2).
CAS: 1302-78-9
RTECS: CT9450000
Fraction By Weight: SEE 1&2%
OSHA PEL 5 MG/M3 (DUST)
ACGIH TLV: 5 MG/M3 (DUST)
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EYE/SKIN CONTACT MAY CAUSE MECHANICAL
IRRITATION IF EXOSED TO LARGE AMOUNTS OF DUST. INHALATION MAY CAUSE
IRRITATION TO RESPIRATORY TRACT AND LUNG DAMAGE IF EXPOSURE IS
REPEATED OR PROLONGED. PROLONGE D/REPEATED INHALATION MAY CAUSE
PULMONARY FIBROSIS (SILICOSIS). NO ADVERSE EFFECTS EXPECTED FROM
INGESTION.
Explanation of Carcinogenicity:CRYSTALLINE SILICA IS LISTED BY IARC AND
NTP. SEE INDIVIDUAL REPORTS FOR DETAILS.
Effects of Overexposure:EYE/SKIN:MECHANICAL IRRITATION.
INHALED:RESPIRATORY TRACT IRRITATION, COUGH, DYSPNEA, WHEEZING,
LUNG DAMAGE, CANCER. INGESTED:NO ADVERSE EFFECTS EXPECTED.
Medical Cond Aggravated by Exposure:MAY AGGRAVATE EXISTING RESPIRATORY
AILMENTS.
First Aid
First Aid:EYE:FLUSH EYES WITH PLENTY OF WATER. IF IRRITATION DEVELOPS,
CALL A PHYSICIAN. SKIN:FLUSH WITH PLENTY OF WATER. IF IRRITATION
DEVELOPS, CALL A PHYSICIAN. INHALED:REMOVE TO FRESH AIR AND SEEK
MEDICAL A TTENTION. GIVE OXYGEN IF BREATHING IS DIFFICULT.
INGESTED:SEEK MEDICAL ADVICE.
Fire Fighting
Flash Point:NON-FLAMMABLE
Extinguishing Media:WATER, CARBON DIOXIDE OR FOAM
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE.
Unusual Fire/Explosion Hazard:NOT A FIRE OR EXPLOSION HAZARD.
Accidental Release
Spill Release Procedures:CONTAIN SPILLAGE AND SCOOP UP OR VACUUM. AVOID
DUSTING.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:USE DUSTLESS SYSTEM AND CLEAN UP SUCH
THAT AIRBORNE DUST DOES NOT EXCEEC PEL. PRACTICE GOOD HOUSEKEEPING.
WASH OR VACUUM CLOTHING WHICH IS DUSTY.
Other Precautions:PRODUCT BECOMES SLIPPERY WHEN WET. MAINTAIN
VENTILATION AND DUST COLLECTION EQUIPMENT.
Exposure Controls
Respiratory Protection:A NIOSH/MSHA-APPROVED RESPIRATOR RESPIRATOR AS
NECESSARY.
Ventilation:GENERAL, LOCAL EXHAUST VENTILATION AS NECESSARY TO CONTROL
ANY AIR CONTAMINANTS, TO WITHIN THEIR TLVS, IN THE USE OF TH.
Protective Gloves:NONE SPECIFIED BY MANUFACTURER.
Eye Protection:SAFETY GLASSES
Other Protective Equipment:NO INFORMATION GIVEN ON MSDS BY MFR.
Work Hygienic Practices:MFR: ? HMIS:USE GOOD CHEMICAL HYGIENE
PRACTICE. AVOID UNNECESSARY CONTACT. WASH THOROUGHLY BEFORE EATING
OR DRINKING.
Supplemental Safety and Health
KEY2:KT REFER TO NIOSH MANUAL OF ANALYTICAL METHODS FOR SAMPLING
METHOD FOR CRYSTALLINE SILICA.
Chemical Properties
HCC:N1
NRC/State Lic Num:NONE
Spec Gravity:2.0
pH:BLANK
Viscosity:NONE
Evaporation Rate & Reference:NONE
Solubility in Water:NEGLIGIBLE
Appearance and Odor:GREY TO OFF-WHITE GRANULES; ODORLESS
Stability
Stability Indicator/Materials to Avoid:YES
NONE EXPERCTED
Stability Condition to Avoid:NONE EXPECTED
Hazardous Decomposition Products:NONE EXPECTED
Conditions to Avoid Polymerization:"NOT APPLICABLE"
Disposal
Waste Disposal Methods:FEDERAL, STATE AND LOCAL DISPOSAL LAWS AND
REGULATIONS WILL DETERMINE THE PROPER WASTE DISPOSAL PROCEDURE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.