BKKNW - PROCESS 92CD-ER COLOR (SEE SUPP DATA)

  • MSDS: BKKNW
  • Manufacturer: AGFA CORP
  • Product Name: PROCESS 92CD-ER COLOR (SEE SUPP DATA)
  • National Stock Number: 6750-00N014106
Product Identification

Product ID:PROCESS 92CD-ER COLOR (SEE SUPP DATA)
MSDS Date:06/01/1988
FSC:6750
NIIN:00N014106
Kit Part:Y
MSDS Number: BKKNW

Responsible Party
AGFA CORPORATION
100 CHALLENGER RD
RIDGEFIELD PARK, NJ 07660
US

Emergency Phone: 303-623-5716;800-424-9300(CHEMTREC)

Info Phone: 201-440-2500

Cage: HO792

Contractor
BAYER CORP / AGFA DIVISION
RIDGEFIELD, NJ 07660 US

Telephone: 201-440-2500

Cage: 59735

Ingredients

HYDROXYLAMINE SULFATE

CAS: 10039-54-0

RTECS: NC5425000

Fraction By Weight: 15-20%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYE/SKIN:MAY CAUSE IRRIT.
INHAL:NORMALLY NO PROBLEM BUT INHAL OF MIST COULD CAUSE RESPIRATORY
IRRIT. INGEST:MAY CAUSE IRRIT OF MUCOUS MEMBRANES OR DIGESTIVE
TRACT. CHRONIC:HYDROXYLAMINE SULFATE HAS BEEN FOUND TO BE
MUTAGENIC IN VITRO. HOWEVER IN LONG TERM ANIMAL STUDIES IT HAS BEEN
SHOWN NOT TO BE CARCINOGENIC.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES:IMMED FLUSH W/PLENTY OF RUNNING WATER FOR AT LEAST 15
MINUTES. CALL MD. SKIN:FLUSH AFFECTED AREAS PROMPTLY W/WATER FOR 15
MINUTES. REMOVE CONTAMINATED CLOTHING. IN CASE OF CONTINUED
IRRITATION, C ALL MD. INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING
(GIVE O*2/ARTIFICIAL RESPIRATION) . INGEST:CALL MD IMMEDIATELY.

Fire Fighting

Flash Point:NONCOMBUSTIBLE
Extinguishing Media:ANY APPLICABLE TO PRIMARY CAUSE OF FIRE.
Fire Fighting Procedures:EVACUATE PERSONNEL TO SAFE AREA. KEEP
PERSONNEL REMOVED & UPWIND OF FIRE. WEAR NIOSH/MSHA APPROVED SCBA
AND FULL PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:WHEN HEATED TO DECOMPOSITION EMISSION OF
TOXIC FUMES OF SO*2 IS POSSIBLE.

Accidental Release

Spill Release Procedures:USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT
DURING CLEAN UP. DIKE SPILL. PREVENT LIQUID FROM ENTERING SEWERS,
WATERWAYS OR LOW AREAS. SOAK UP W/SAWDUST, SAND, OIL DRY OR OTHER
ABSORBENT MATERIAL.
Neutralizing Agent:POWDERED SODIUM CARBONATE.

Handling

Handling and Storage Precautions:STORE IN WELL VENT AREA. KEEP CNTNR
TIGHTLY CLOSED. DO NOT STORE W/INCOMPATIBLE MATLS. DO NOT STORE OR
CONSUME FOOD, DRINK OR TOBACCO (SEE SUPP DATA)
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NONE NEEDED W/WORKING MIXTURES & NORMAL ROOM
VENTILATION. IF NEEDED, USE NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:ROOM VENTILATION IS SUFFICIENT. AVOID USE OF PRODUCT IN
UNVENTILATED AREAS.
Protective Gloves:CHEMICAL GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:CHEMICAL RESISTANT APRONS.
Work Hygienic Practices:WASH HANDS THOROUGHLY AFTER USE AND BEFORE
EATING, DRINKING, SMOKING OR USING SANITARY FACILITIES .
Supplemental Safety and Health
MFR TRADE NAME/PART NO:DEVELOPER REPLENISHER PART B. WASTE DISP
METH:AUTHORITY & MAY REQUIRE PRETREATMENT. DISPOSE I/A/W FEDERAL,
STATE AND LOCAL REGULATIONS . HNDLG/STOR PREC:IN AREA WHERE THEY
MAY BECOME CONTAMINATED W/THIS MATERIAL.

Chemical Properties

HCC:C2
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:21.07
Vapor Density:SAME/WATER
Spec Gravity:1.215
pH:2.8
Evaporation Rate & Reference:0.3 (N-BUTYL ACETATE = 1)
Solubility in Water:100%
Appearance and Odor:CLEAR, COLORLESS, NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES, OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:AMMONIA, SO*X, NO*X.

Disposal

Waste Disposal Methods:RECOVER NONUSABLE FREE LIQ &/OR CONTAM WATER &
DISPOSE OF IN APPRVD/PERMITTED TREATMENT SYS. REMOVE NONUSABLE
SOLID MATL &/OR CONTAM SOIL FOR DISPOSAL IN APPRVD/PERMITTED
LANDFILL. DISCHARGE TO SEWER REQUIRES APPROVAL OF PERMITTING (SEE
SUPP DATA)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.