BLJCL - TITAN GEL IFE BUFFER, 3067
- MSDS: BLJCL
- Manufacturer: HELENA LABORATORIES
- Product Name: TITAN GEL IFE BUFFER, 3067
- National Stock Number: 6550-00N021068
Product Identification
Product ID:TITAN GEL IFE BUFFER, 3067
MSDS Date:01/01/1989
FSC:6550
NIIN:00N021068
MSDS Number: BLJCL
Responsible Party
BEAUMONT, TX 77704-0752
US
Emergency Phone: 800-231-5663, 800-392-3126
Info Phone: 800-231-5663, 800-231-4678
Preparer: MARC BARCLAY
Cage: 53738
Contractor
Telephone: 800-231-5663/800-392-3126 (TEXAS)
Cage: 53738
Ingredients
SODIUM AZIDE (SARA III)
CAS: 26628-22-8
RTECS: VY8050000
Fraction By Weight: 5.9%
OSHA PEL S, C 0.1 PPM(HN3)
ACGIH TLV: C 0.11 PPM; 9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:LD50: (ORAL, MUS) 27 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: HIGHLY TOXIC - AVOID
INHALATION OF VAPORS AND/OR DUST. CAUSES FALL IN BLOOD PRESSURE,
CYANOSIS. INGEST: HIGHLY TOXIC.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NOT LISTED.
First Aid
First Aid:EYE: WASH W/COPIOUS AMTS OF WATER FOR AT LEAST 15 MINUTES.
CONSULT MD. SKIN: WASH W/COPIOUS AMTS OF WATER FOR 15 MINUTES.
CONSULT MD. INHAL: REMOVE FROM EXPOSURE. IF BREATHING HAS STOPPED,
APPLY ARTF RESP. CALL MD IMMEDIATELY. INGEST: EMPHASIS SHOULD BE
PLACED ON THE TOXICITY OF THIS MATERIAL. INDUCE VOMITING
IMMEDIATELY; IF CONSCIOUS, STOMACH WASH, IF UNCONSCIOUS, GET
MEDICAL HELP OR CALL MD.
Fire Fighting
Extinguishing Media:WATER, FOAM OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:ON HEATING, DECOMPOSES INTO SODIUM AND
NITROGEN.
Accidental Release
Spill Release Procedures:SPONGE UP W/H2O FOLLOWED W/10% AMMONIUM
NITRATE SOLN. "KILL" BY ADDING TO A GREATER THAN STOCHIOMETRIC AMT
OF 10% CERIC AMMONIUM NITRATE SOLN (W/OUT ACID) W/GOOD STIRRING
INSIDE A LAB HOOD. COOL REACT ION. FLUSH TO DRAIN W/PLENTY OF H2O.
(SUPP DATA)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DANGEROUS: DO NOT STORE/LOAD W/ANY
HIGH EXPLOSIVES. SODIUM AZIDE IS NOT CONSIDERED EXPLO UNDER NORMAL
LAB CONDITIONS.
Other Precautions:NONE.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED DUST RESPIRATOR.
Ventilation:LOCAL EXHAUST: HOOD SYSTEM (>100 CFM VELOCITY).
Protective Gloves:RUBBER GLOVES (LONG SLEEVES).
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:RUBBER APRON, LAB COAT OR OVERALLS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPILL PROC: IT IS WELL ESTABLISHED THAT SODIUM AZIDE CAN REACT W/BOTH
COPPER & LEAD TO PRODUCE EXPLOSIVE METAL AZIDES, & IN THE PAST 8
YEARS THERE HAVE BEEN 7 REPORTS OF "EXPLOSIONS" IN LABORATORY PLU
MBING SYSTEMS CONTAINING SODIUM AZIDE. REF: COLLEGE OF AM.
PATHOLOGISTS, JULY 1980, PP 337-339.
Chemical Properties
HCC:T3
Melt/Freeze Pt:M.P/F.P Text:572F,300C
Spec Gravity:1.846
Solubility in Water:40
Appearance and Odor:COLORLESS, HEXAGONAL CRYSTALS.
Stability
Stability Indicator/Materials to Avoid:NO
VIOLENT REACTION WITH BENZOYL CHLORIDE + KOH, BR2, CS2 + HNO3.
Stability Condition to Avoid:SHOCK AND HEAT.
Hazardous Decomposition Products:ON HEATING, DECOMPOSES INTO SODIUM AND
NITROGEN.
Disposal
Waste Disposal Methods:DISPOSE OF BY MEANS AS TO COMPLY WITH ALL LOCAL,
STATE AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their