BLMHW - OMC HI-VIS GEAR LUBE 31-250, 173241
- MSDS: BLMHW
- Manufacturer: CITGO PETROLEUM CORP
- Product Name: OMC HI-VIS GEAR LUBE 31-250, 173241
- National Stock Number: 9150-00N021275
Product Identification
Product ID:OMC HI-VIS GEAR LUBE 31-250, 173241
MSDS Date:05/08/1989
FSC:9150
NIIN:00N021275
MSDS Number: BLMHW
Responsible Party
Emergency Phone: 318-491-6215 800-424-9300(CHEMTREC)
Info Phone: 918-495-5933
Cage: 7X110
Contractor
Telephone: 918-495-5933
Cage: 7X110
Ingredients
REFINED HEAVY PARAFFINIC DISTILLATES
CAS: 64741-88-4
Fraction By Weight: 97-99%
OSHA PEL 5 MG/M3 (OIL MIST)
ACGIH TLV: 5 MG/M3 (OIL MIST)
EXTREME PRESSURE, OXIDATION AND RUST INHIBITOR
Fraction By Weight: 1-4%
VI IMPROVER
Fraction By Weight: <0.1%
REQS PROMPT SURGICAL DEBRIDEMENT. IF NOT
RTECS: 9999999ZZ
AT 100 F=740.
RTECS: 9999999ZZ
MANDATED STANDARDS AS EVALUATED BY DESIGNATED
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:LD50: (ORAL,RAT) >15 G/KG.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: LOW RISK OF INHALATION.
IN ENCLOSED SPACES/WHEN HOT, VAPORS MAY REACH CONCENTRATIONS
SUFFICIENT TO CAUSE DROWSINESS, DIZZINESS, HEADACHE, NAUSEA, OR
LUNG IRRITATION. MISTS ABOVE TLV MAY CAUSE CHEM PNEUM. SKIN: LOW
IRRITANT. EYE: MAY BE MILDLY (SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:CAS NO.64741-88-4 IS LISTED BY THE RTECS
AS AN IARC GROUP 1 CARCINOGEN.
Effects of Overexposure:HLTH HAZ: IRRIT. INGEST: GENERALLY LOW
TOXICITY. VERY LARGE AMOUNTS MAY CAUSE GENERALIZED DEPRESSION,
HEADACHE, DROW, NAUS, VOMIT/DIARRHEA. SMALL DOSES MAY PRODUCE
IRRITATION AND DIARRHEA. INJECTION: ERYTHEMA, EDEMA, IRRIT.
CHORNIC: PROLONGED AND/OR FREQUENT CONTACT MAY CAUSE DRYING,
CRACKING (DERM) OR FOLLICULITIS.
Medical Cond Aggravated by Exposure:NONE.
First Aid
First Aid:INHAL: REMOVE TO FRESH AIR. RESP SUPPORT IF NEC. SEEK MED
AID. SKIN: WASH W/SOAP & H2O. DO NOT WEAR HEAVILY CONTAM CLTHG
BEFORE LAUNDERING. EYE: FLUSH W/LRG VOL OF H2O FOR AT LEAST 15 MIN.
SEE PHYS IF ANY COMPLICATIONS ARISE. INGEST: DO NOT INDUCE
VOMITING. SEEK MED AID. INJECTION: SUBCUTANEOUS INJECTION IS MED
EMER. SEEK MED AID IMMED. NOTES TO PHYS: IF VISCOSITY IS <100 SUS
AT 100 F, (SUP DAT)
Fire Fighting
Flash Point Method:COC
Flash Point:460F,238C
Extinguishing Media:CO2, DRY CHEMICAL, FOAM, WATER FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:WATER MAY CAUSE FROTHING.
Accidental Release
Spill Release Procedures:REMOVE SOURCES OF HEAT OR IGNITION, PROVIDE
ADEQ VENT, CONTAIN LEAK. SMALL SPILLS: ABSORB WITH SUITABLE
MATERIAL SUCH AS RAGS, STRAW OR SAND. LRG SPILLS: CONTAIN SPILL IN
EARTHEN DIKES FOR LATER RECOV ERY. REPORT SPILLS AS REQD TO APPROP
AUTHORITIES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE BELOW 150 F DO NOT APPLY HIGH
HEAT OR FLAME TO CONTAINER. KEEP SEPARATE FROM STRONG OXIDIZING
AGENTS.
Other Precautions:EMPTY CNTNRS MAY CONTAIN PRODUCT RESIDUE WHICH COULD
INCLUDE FLAMMABLE OR EXPLOSIVE VAPS. CONSULT APPROP FED, STATE &
LOCAL AUTHORITIES BEFORE REUSING, RECONDITIONING, RECLAIMING,
RECYCLING/DISP OF EM PTY CNTNRS &/OR WASTE RESIDUES OF PROD.
Exposure Controls
Respiratory Protection:NORMALLY NONE REQUIRED. IF HIGH VAPOR OR MIST
CONCETRATIONS EXPECTED-USE NIOSH/MSHA APPROVED RESPIRATOR FOR
ORGANIC VAPORS AND MISTS.
Ventilation:USE IN WELL VENT AREA. IN CONFINED SPACES, MECH VENT MAY BE
REQD TO KEEP LEVS OF CERTAIN COMPONENTS BELOW (INGRED 6)
Protective Gloves:OIL IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WEAR BODY-COVERING WORK CLOTHES TO AVOID
PROLONGED OR REPEATED EXPOSURE.
Work Hygienic Practices:LAUNDER SOILED WORK CLOTHES BEFORE REUSE.
Supplemental Safety and Health
% VOLAT: NEGLIGIBLE. FIRST AID PROC: CAREFUL GASTRIC LAVAGE W/TIGHT
FITTING/CUFFED TUBE IS TO BE PREFERRED OVER EMESIS. IF VISCOSITY IS
>100 SUS @ 100 F, EMESIS MAY BE INDUCED FOR LRG QTYS. ASPIR MAY
CAUSE CHEM PNEUM/LIPOID PNEUM. SUBCUTANEOUS INJECTION (ING 4)
Chemical Properties
HCC:V6
Boiling Pt:B.P. Text:750F,399C
Vapor Pres:<3 X 10.4
Vapor Density:>1
Spec Gravity:0.89
Evaporation Rate & Reference:<1 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER LIQUID, SLIGHT SULFURIZED ODOR.
Percent Volatiles by Volume:SUPDAT
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:CO2, (CO UNDER INCOMPLETE COMBUSTION)
Disposal
Waste Disposal Methods:IT IS RESPONSIBILITY OF USER TO DETERMINE IF
MATERIAL IS HAZ WASTE AT TIME OF DISPOSAL. CHECK BEFORE DISPOSING
TO BE SURE YOU ARE IN COMPLIANCE WITH ALL FEDERAL, STATE AND LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.