BLMHX - OMC HI-VIS GEAR LUBE 31-250, 173243

  • MSDS: BLMHX
  • Manufacturer: CITGO PETROLEUM CORP
  • Product Name: OMC HI-VIS GEAR LUBE 31-250, 173243
  • National Stock Number: 9150-00N021276
Product Identification

Product ID:OMC HI-VIS GEAR LUBE 31-250, 173243
MSDS Date:05/08/1989
FSC:9150
NIIN:00N021276
MSDS Number: BLMHX

Responsible Party
CITGO PETROLEUM CORP
TULSA, OK 74102

Emergency Phone: 318-491-6215 800-424-9300(CHEMTREC)

Info Phone: 918-495-5933

Cage: 7X110

Contractor
CITGO PETROLEUM CORP
3758 TULSA, OK 74102 US

Telephone: 918-495-5933

Cage: 7X110

Ingredients

VI IMPROVER

Fraction By Weight: <0.1%


MANDATED STANDARDS AS EVALUATED BY DESIGNATED

RTECS: 9999999ZZ


REFINED HEAVY PARAFFINIC DISTILLATES

CAS: 64741-88-4

Fraction By Weight: 97-99%

OSHA PEL 5 MG/M3 (OIL MIST)

ACGIH TLV: 5 MG/M3 (OIL MIST)


EXTREME PRESSURE, OXIDATION AND RUST INHIBITOR

Fraction By Weight: 1-4%

Hazards

LD50 LC50 Mixture:LD50: (ORAL,RAT) >15 G/KG.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: LOW RISK OF INHALATION. IN
ENCLOSED SPACES/WHEN HOT, VAPS MAY REACH CONCENTRATIONS SUFFICIENT
TO CAUSE DROW, DIZZ, HDCH, NAUSEA, OR LUNG IRRITATION. MISTS ABOVE
TLV MAY CAUSE CHEM PNEUM. SKIN: LOW IRRITANT. EYE: MAY BE MILDLY
IRRIT.INGEST: GENERALLY (SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:CAS NO.64741-88-4 IS LISTED BY THE RTECS
AS AN IARC GROUP 1 CARCINOGEN.
Effects of Overexposure:HLTH HAZ: LOW TOXICITY. VERY LARGE AMOUNTS MAY
CAUSE GENERALIZED DEPRESSION, HEADACHE, DROW, NAUS, VOMIT/DIARRHEA.
SMALL DOSES MAY PRODUCE IRRITATION AND DIARRHEA. INJECTION:
ERYTHEMA, EDEMA, IRRITATI ON. CHRONIC: PROLONGED AND/OR FREQUENT
CONTACT MAY CAUSE DRYING, CRACKING (DERMATITIS) OF FOLLICULITIS.
Medical Cond Aggravated by Exposure:NONE.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. RESP SUPPORT IF NEC. SEEK MED
AID. SKIN: WASH W/SOAP & H2O. DO NOT WEAR HEAVILY CONTAM CLTHG
BEFORE LAUNDERING. EYES: FLUSH W/LRG VOL OF H2O FOR AT LEAST 15
MIN. SEE PHYS I F ANY COMPLICATIONS ARISE. INGEST: DO NOT INDUCE
VOMIT. SEEK MED AID. INJECTION: SUBCUTANEOUS INJECTION IS MED EMER.
SEEK MED AID IMMED. NOTES TO PHYS: IF VISCOSITY IS > 100 SUS @ 100
F, (SUP DAT)

Fire Fighting

Flash Point Method:COC
Flash Point:460F,238C
Extinguishing Media:CO2, DRY CHEMICAL, FOAM, WATER FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:WATER MAY CAUSE FROTHING.

Accidental Release

Spill Release Procedures:REMOVE SOURCES OF HEAT OR IGNITION, PROVIDE
ADEQ VENT, CONTAIN LEAK. SMALL SPILLS: ABSORB WITH SUITABLE MATL
SUCH AS RAGS, STRAW/SAND. LARGE SPILLS: CONTAIN SPILL IN EARTHEN
DIKES FOR LATER RECOVERY. REPORT SPILLS AS REQD TO APPROP
AUTHORITIES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE BELOW 150 F DO NOT APPLY HIGH
HEAT OR FLAME TO CONTAINER. KEEP SEPARATE FROM STRONG OXIDIZING
AGENTS.
Other Precautions:EMPTY CNTNRS MAY CONTAIN PROD RESIDUE WHICH COULD
INCLUDE FLAM/EXPLO VAPS. CONSULT APPROP FEDERAL, STATE AND LOCAL
AUTHORITIES BEFORE REUSING, RECONDITIONING, RECLAIMING, RECYCLING
OR DISPOSING OF EMP TY CNTNRS &/OR WASTE RESIDUES OF PROD.

Exposure Controls

Respiratory Protection:NORMALLY NONE REQUIRED. IF HIGH VAPOR OR MIST
CONCENTRATIONS EXPECTED-USE NIOSH/MSHA APPROVED RESPIRATOR FOR
ORGANIC VAPORS AND MISTS.
Ventilation:USE IN WELL VENT AREA. IN CONFINED SPACES, MECH VENT MAY BE
REQD TO KEEP LEVS OF CERTAIN COMPONENTS BELOW (INGRED 4)
Protective Gloves:OIL IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WEAR BODY-COVERING WORK CLOTHES TO AVOID
PROLONGED OR REPEATED EXPOSURE.
Work Hygienic Practices:LAUNDER SOILED WORK CLOTHES BEFORE REUSE.
Supplemental Safety and Health
% VOLAT: NEGLIGIBLE. FIRST AID PROC: EMESIS MAY BE INDUCED FOR LRG
QTYS. ASPIR MAY CAUSE CHEM PNEUM/LIPOID PNEUM. SUBCUTANEOUS
INJECTION REQS PROMPT SURGICAL DEBRIDEMENT. IF NOT FAMILIAR W/
TECHNIQUE, SEEK SKILLED ADVICE. SUS VISCOSITY AT 100F=740.

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:750F,399C
Vapor Pres:<3 X 10.4
Vapor Density:>1
Spec Gravity:0.89
Evaporation Rate & Reference:<1 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER LIQUID. SLIGHT SULFURIZED ODOR.
Percent Volatiles by Volume:SUPDAT

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:CO2 (CO UNDER INCOMPLETE COMBUSTION)

Disposal

Waste Disposal Methods:IT IS RESPONSIBILITY OF USER TO DERMINE IF MATL
IS HAZ WASTE AT TIME OF DISPOSAL. CHECK BEFORE DISPOSING TO BE SURE
YOU ARE IN COMPLIANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.