BLMHZ - OMC HI-VIS GEAR LUBE 31-250, 175121

  • MSDS: BLMHZ
  • Manufacturer: CITGO PETROLEUM CORP
  • Product Name: OMC HI-VIS GEAR LUBE 31-250, 175121
  • National Stock Number: 9150-00N021278
Product Identification

Product ID:OMC HI-VIS GEAR LUBE 31-250, 175121
MSDS Date:05/08/1989
FSC:9150
NIIN:00N021278
MSDS Number: BLMHZ

Responsible Party
CITGO PETROLEUM CORP
TULSA, OK 74102

Emergency Phone: 318-491-6215 800-424-9300(CHEMTREC)

Info Phone: 918-495-5933

Cage: 7X110

Contractor
CITGO PETROLEUM CORP
3758 TULSA, OK 74102 US

Telephone: 918-495-5933

Cage: 7X110

Ingredients

REFINED HEAVY PARAFFINIC DISTILLATES

CAS: 64741-88-4

Fraction By Weight: 97-99%

OSHA PEL 5 MG/M3 (OIL MIST)

ACGIH TLV: 5 MG/M3 (OIL MIST)


EXTREME PRESSURE, OXIDATION AND RUST INHIBITOR

Fraction By Weight: 1-4%


VI IMPROVER

Fraction By Weight: <0.1%


SURGICAL DEBRIDEMENT. IF NOT FAMILIAR WITH

RTECS: 9999999ZZ


MANDATED STANDARDS AS EVALUATED BY DESIGNATED

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: LOW RISK OF INHAL. IN ENCLOSED
SPACES/WHEN HOT, VAPS MAY REACH CONC SUFFICIENT TO CAUSE DROW,
DIZZ, HDCH, NAUS, OR LUNG IRRIT. MISTS ABOVE TLV MAY CAUSE CHEM
PNEUM. SKIN: LOW IRRIT. EYE: MAY BE MILDLY IRRITATING. INGEST:
GENERALLY LOW TOXICITY. VERY LARGE (SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:CAS NO.64741-88-4 IS LISTED BY THE RTECS
AS AN IARC GROUP 1 CARCINOGEN.
Effects of Overexposure:HLTH HAZ: AMTS MAY CAUSE GENERALIZED
DEPRESSION, HEADACHE, DROWSINESS, NAUSEA, VOMITING OR DIARRHEA.
SMALL DOSES MAY PRODUCE IRRITATION AND DIARRHEA. INJECTION:
ERYTHEMA, EDEMA, IRRITATION. CHRONIC: P ROLONGED AND/OR FREQUENT
CONTACT MAY CAUSE DRYING CRACKING (DERMATITIS) OF FOLLICULITIS.
Medical Cond Aggravated by Exposure:NONE.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. RESP SUPPORT IF NEC. SEEK MED
AID. SKIN: WASH W/SOAP & H2O. DO NOT WEAR HEAVILY CONTAM CLTHG
BEFORE LAUNDERING. EYES: FLUSH W/LRG VOL OF H2O. SEE PNYS IF ANY
COMPLICATIONS ARISE. INGEST: DO NOT INDUCE VOMIT. SEEK MED AID.
INJECTION: SUBCUTANEOUS INJECTION IS MED EMER. SEEK MED AID IMMED.
NOTES TO PHYS: IF VISCOSITY IS <100 SUS AT 100 F, CAREFUL GASTRIC
(SUPP DATA)

Fire Fighting

Flash Point Method:COC
Flash Point:460F,238C
Extinguishing Media:CO2, DRY CHEMICAL, FOAM, WATER FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:WATER MAY CAUSE FROTHING.

Accidental Release

Spill Release Procedures:REMOVE SOURCES OF HEAT/IGNIT, PROVIDE ADEQ
VENT, CONTAIN LEAK. SMALL SPILL: ABSORB W/SUITABLE MATL SUCH AS
RAGS, STRAW/SAND. LRG SPILL: CONTAIN SPILL IN EARTHEN DIKES FOR
LATER RECOVERY. REPORT SPILLS AS REQD TO APPROPRIATE AUTHORITIES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE BELOW 150 F. DO NOT APPLY HIGH
HEAT/ FLAME TO CONTAINER. KEEP SEPARATE FROM STRONG OXIDIZING
AGENTS.
Other Precautions:EMPTY CNTNRS MAY CONTAIN PROD RESIDUE WHICH COULD
INCLUDE FLAMMABLE OR EXPLO VAPS. CONSULT APPROP FEDERAL, STATE AND
LOCAL AUTHORITIES BEFORE REUSING, RECONDITIONING, RECLAIMING,
RECYCLING/DISP OF EMP TY CNTNRS &/OR WASTE RESIDUES OF PROD.

Exposure Controls

Respiratory Protection:NORMALLY NONE REQUIRED. IF HIGH VAPOR OR MIST
CONCENTRATIONS EXPECTED-USE NIOSH/MSHA APPROVED RESPIRATOR FOR
ORGANIC VAPORS AND MISTS.
Ventilation:USE IN WELL VENT AREA. IN CONFINED SPACES, MECH VENT MAY BE
REQD TO KEEP LEVS OF CERTAIN COMPONENTS BELOW (ING 5)
Protective Gloves:OIL IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WEAR BODY-COVERING WORK CLOTHES TO AVOID
PROLONGED OR REPEATED EXPOSURE. LAUNDER SOILED WORK CLOTHES BEFORE
REUSE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
% VOLAT: NEGLIGIBLE. FIRST AID PROC: LAVAGE W/TIGHT FITTING/CUFFED TUBE
IS TO BE PREFERRED OVER EMESIS. IF VISCOSITY IS >100 SUS AT 100F,
EMESIS MAY BE INDUCED FOR LRG QTYS. ASPIR MAY CAUSE CHEM PNEUM
/LIPOID PNEUM. SUBCUTANEOUS INJECTION REQS PROMPT (ING 4)

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:750F,399C
Vapor Pres:<3 X 10.4
Vapor Density:>1
Spec Gravity:0.89
Evaporation Rate & Reference:<1 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER LIQUID, SLIGHT SULFURIZED ODOR.
Percent Volatiles by Volume:SUPDAT

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:CO2, (CO UNDER INCOMPLETE COMBUSTION).

Disposal

Waste Disposal Methods:IT IS RESPONSIBILITY OF USER TO DETERMINE IF
MATL IS HAZ WASTE AT TIME OF DISP. CHECK BEFORE DISPOSING TO BE
SURE YOU ARE IN COMPLIANCE WITH ALL APPLIC LAWS AND REGS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.