BLMJC - OMC HI-VIS GEAR LUBE 31-250, 174980

  • MSDS: BLMJC
  • Manufacturer: CITGO PETROLEUM CORP
  • Product Name: OMC HI-VIS GEAR LUBE 31-250, 174980
  • National Stock Number: 9150-00N021281
Product Identification

Product ID:OMC HI-VIS GEAR LUBE 31-250, 174980
MSDS Date:05/08/1989
FSC:9150
NIIN:00N021281
MSDS Number: BLMJC

Responsible Party
CITGO PETROLEUM CORP
TULSA, OK 74102
US

Emergency Phone: 318-491-6215;800-424-9300(CHEMTREC)

Info Phone: 918-495-5933

Cage: 7X110

Contractor
CITGO PETROLEUM CORP
3758 TULSA, OK 74102 US

Telephone: 918-495-5933

Cage: 7X110

Ingredients

MINERAL OIL, PETROLEUM DISTILLATES, SOLVENT-REFINED HEAVY

CAS: 64741-88-4

Fraction By Weight: 97-99%

OSHA PEL 5 MG/M3 (OIL MIST)

ACGIH TLV: 5 MG/M3 (OIL MIST)


EXTREME PRESSURE, OXIDATION AND RUST INHIBITOR

Fraction By Weight: 1-4%


VI IMPROVER

Fraction By Weight: <0.1%


STANDARDS AS EVALUATED BY DESIGNATED PERSONNEL.

RTECS: 9999999ZZ


SUS VISCOSITY AT 100F = 740.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50:(ORAL,RAT) >15 G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:(ACUTE) INHAL: LOW RISK OF INHAL. IN
ENCLOSED SPACES/WHEN HOT, VAPS MAY REACH CONC SUFFICIENT TO CAUSE
DROWS, DIZZ, HDCH, NAUS/LUNG IRRIT. MISTS >TLV CAUSE CHEM PNEUM.
SKIN: LOW IRRITANT. ABSORP: NO P ROBABLE ACUTE HAZARD. EYE: MAY BE
MILDLY IRRITATING. INGEST: GENERALLY LOW TOXICITY. VERY LRG AMTS
(SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:CAS NO.64741-88-4 IS LISTED BY THE RTECS
AS AN IARC GROUP 1 CARCINOGEN.
Effects of Overexposure:HLTH HAZ: MAY CAUSE GENERALIZED DEPRESS, HDCH,
DROWS, NAUS, VOMIT/DIARR. SM DOSES MAY PRODUCE IRRIT & DIARR.
INJECTION: ERYTHEMA, EDEMA, IRRIT. (CHRONIC) PROLONGED AND/OR
FREQUENT CONTACT MAY CAUSE DR YING, CRACKING (DERMAT) OR
FOLLICULITIS.
Medical Cond Aggravated by Exposure:NONE

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. RESPIRATORY SUPPORT IF NECESSARY.
SEEK MD. SKIN: WASH WITH SOAP & WATER. DO NOT WEAR HEAVILY
CONTAMINATED CLTHG BEFORE LAUNDERING. EYES: FLUSH W/LRG VOLUMES OF
WATER. SEE M D IF ANY COMPLICATIONS ARISE. INGEST: DO NOT INDUCE
VOMITING. SEEK MD. INJECTION: SUBCUTANEOUS INJECTION IS A MEDICAL
EMER. SEEK MD IMMED. NOTE TO MD: IF VISCOSITY IF <100 SUS @ 100F,
(SUPP DATA)

Fire Fighting

Flash Point Method:COC
Flash Point:460F,238C
Extinguishing Media:CO2, DRY CHEMICAL, FOAM, WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:WATER MAY CAUSE FROTHING.

Accidental Release

Spill Release Procedures:REMOVE SOURCES OF HEAT/IGNIT, PROVIDE ADEQ
VENT, CONTAIN LEAK. SM SPILLS: ABSORB W/SUITABLE MATL SUCH AS RAGS,
STRAW/ SAND. LRG SPILLS: CONTAIN SPILL IN EARTHEN DIKES FOR LATER
RECOVERY. RPT SPILLS AS REQUIRED TO APPROPRIATE AUTHORITIES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE <150F.DO NOT APPLY HIGH
HEAT/FLAME TO CNTNR.KEEP SEPARATE FROM STRONG OXIDIZING
AGENTS.AVOID PRLNGD CONT. REMOVE&CLEAN SOILED CLTHG BEFORE REUSE
Other Precautions:CAUTION: EMPTY CNTNRS MAY CONTAIN PROD RESIDUE WHICH
COULD INCLUDE FLAM/EXPLO VAPS. CONSULT APPROP FED, ST & LOCAL
AUTHORITIES BEFORE REUSING, RECONDITIONING, RECLAIMING, RECYCLING
OR DISPOSING OF EMP TY CNTNRS AND/OR WASTE RESIDUES OF PROD.

Exposure Controls

Respiratory Protection:NORMALLY NONE REQUIRED. IF HIGH VAPOR OR MIST
CONCENTRATIONS EXPECTED - USE NIOSH/MSHA APPROVED RESPIRATOR FOR
ORGANIC VAPORS AND MISTS.
Ventilation:USE IN WELL VENT AREA. IN CONFINED SPACES, MECH VENT MAY BE
REQ TO KEEP LEV OF CERTAIN COMPONENTS Protective Gloves:OIL IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WEAR BODY-COVERING WORK CLOTHES TO AVOID
PROLONGED OR REPEATED EXPOSURE. LAUNDER SOILED WORK CLOTHES BEFORE
REUSE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID PROC:CAREFUL GASTRIC LAVAGE W/ TIGHT FITTING/CUFFED TUBE IS
TO BE PREF OVER EMESIS. IF VISCOSITY IS >100 SUS @ 100F, EMESIS MAY
BE INDUCED FOR LRG QTYS. ASPIR MAY CAUSE CHEM PNEUM/ LIPOID PN EUM.
SUBCUTANEOUS INJECTION REQ PROMPT SURGICAL DEBRIDEMENT. IF NOT
FAMILIAR W/TECHNIQUE, SEEK SKILLED ADVICE.(SEE ING 5

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:750F,399C
Vapor Pres:<0.0003
Vapor Density:>1
Spec Gravity:0.89
Evaporation Rate & Reference:<1 (BUTYL ACETATE = 1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER LIQUID, SLIGHT SULFURIZED ODOR.
Percent Volatiles by Volume:NEG

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS.
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:CO2 (CO UNDER INCOMPLETE COMBUSTION).

Disposal

Waste Disposal Methods:IT IS RESPONSIBILITY OF USER TO DETERMINE IF
MATL IS HAZ WASTE AT TIME OF DISP. CHECK BEFORE DISPOSING TO BE
SURE YOU ARE IN COMPLIANCE W/ALL APPLIC LAWS & REGS. CHEMTREC/RCRA
EMERGENCY NUMBER: 800- 4 24-9346.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their