BLNQX - OMC HI-VIS GEAR LUBE 31-250, 173244

  • MSDS: BLNQX
  • Manufacturer: CITGO PETROLEUM CORP
  • Product Name: OMC HI-VIS GEAR LUBE 31-250, 173244
  • National Stock Number: 9150-00N021280
Product Identification

Product ID:OMC HI-VIS GEAR LUBE 31-250, 173244
MSDS Date:05/08/1989
FSC:9150
NIIN:00N021280
MSDS Number: BLNQX

Responsible Party
CITGO PETROLEUM CORP
TULSA, OK 74102
US

Emergency Phone: 318-491-6215;800-424-9300(CHEMTREC)

Info Phone: 918-495-5933

Cage: 7X110

Contractor
CITGO PETROLEUM CORP
3758 TULSA, OK 74102 US

Telephone: 918-495-5933

Cage: 7X110

Ingredients

REFINED HEAVY PARAFFINIC DISTILLATES

CAS: 64741-88-4

Fraction By Weight: 97-99%

OSHA PEL 5 MG/M3 (OIL MIST)

ACGIH TLV: 5 MG/M3 (OIL MIST)


REFINED PETROLEUM OIL(S)

CAS: 64742-01-4

Fraction By Weight: 97-99%


EXTREME PRESSURE, OXIDATION AND RUST INHIBITOR

Fraction By Weight: 1-4%


VI IMPROVER

Fraction By Weight: <0.1%


ADVICE. SUS VISCOSITY AT 100 F=740.

RTECS: 9999999ZZ


MANDATED STANDARDS AS EVALUATED BY DESIGNATED

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50: (ORAL,RAT) >15 G/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: LOW RISK OF INHAL. IN
ENCLOSED SPACES/WHEN HOT, VAPS MAY REACH CONC SUFFICIENT TO CAUSE
DROW, DIZZ, HDCH, NAUS/LUNG IRRIT. MISTS ABOVE TLV MAY CAUSE CHEM
PNEUM. SKIN: LOW IRRIT. SKIN ABS ORP: NO PROBABLE ACUTE HAZ. EYE:
MAY BEMILDLY IRRIT. INGEST: GENERALLY LOW TOXICITY. VERY LRG (SEE
EFTS OF OVEREXP)
Explanation of Carcinogenicity:REFINED HEAVY PARAFFINIC
DISTILLATES:LISTED IN IARC AS A GROUP 1 CARCINOGEN.
Effects of Overexposure:HLTH HAZ: AMTS MAY CAUSE GENERALIZED
DEPRESSION, HDCH, DROW, NAUS, VOMIT/DIARRHEA. SMALL DOSES MAY
PRODUCE IRRITATION & DIARRHEA. INJECTION: ERYTHEMA, EDEMA, IRRIT.
CHRONIC: PROLONGED AND/OR FREQUENT CONTACT MAY CAUSE DRYING,
CRACKING (DERMATITIS) OR FOLLICULITIS.
Medical Cond Aggravated by Exposure:NONE.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. RESP SUPPORT IF NEC. SEEK MED
AID. SKIN: WASH W/SOAP & H2O. DO NOT WEAR HEAVILY CONTAM CLTHG
BEFORE LAUNDERING. EYES: FLUSH W/LRG VOL OF H2O. SEE PHYS IF ANY
COMPLICATIONS ARISE. INGEST: DO NOT INDUCE VOMIT. SEEK MED AID.
INJECTION: SUBCUTANEOUS INJECTION IS MED EMER. SEEK MED AID IMMED.
NOTES TO PHYS: IF VISCOSITY IS < 100 SUS @ 100 F, CAREFUL GASTRIC
LAVAGE(SUP DAT)

Fire Fighting

Flash Point Method:COC
Flash Point:460F,238C
Extinguishing Media:CO2, DRY CHEMICAL, FOAM, WATER FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:WATER MAY CAUSE FROTHING.

Accidental Release

Spill Release Procedures:REMOVE SOURCES OF HEAT/IGNIT, PROVIDE ADEQUATE
VENTILATION, CONTAIN LEAK. SMALL SPILLS: ABSORB W/SUITABLE MATERIAL
SUCH AS RAGS, STRAW/SAND. LRG SPILLS: CONTAIN SPILL IN EARTHEN
DIKES FOR LATER RECOVE RY. REPORT SPILLS AS REQD TO APPROP
AUTHORITIES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE BELOW 150 F. DO NOT APPLY HIGH
HEAT OR FLAME TO CONTAINER. KEEP SEPARATE FROM STRONG OXIDIZING
AGENTS.
Other Precautions:EMPTY CONTAINERS MAY CONTAIN PRODUCT RESIDUE WHICH
COULD INCLUDE FLAM/EXPLO VAPORS. CONSULT APPROP FED, STATE & LOCAL
AUTHORITIES BEFORE REUSING, RECONDITIONING, RECLAIMING,
RECYCLING/DISP OF EMPTY CN TNRS &/OR WASTE RESIDUES OF PRODUCT.

Exposure Controls

Respiratory Protection:NORMALLY NONE REQUIRED. IF HIGH VAPOR OR MIST
CONCENTRATIONS EXPECTED-USE NIOSH/MSHA APPROVED RESPIRATOR FOR
ORGANIC VAPORS AND MISTS.
Ventilation:USE IN WELL VENT AREA. IN CONFINED SPACED, MECH VENT MAY BE
REQD TO KEEP LEVS OF CERTAIN COMPONENTS BELOW (INGRED 6)
Protective Gloves:OIL IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WEAR BODY-COVERING WORK CLOTHES TO AVOID
PROLONGED OR REPEATED EXPOSURE. LAUNDER SOILED WORK CLOTHES BEFORE
REUSE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
% VOLAT: NEGLIGIBLE. FIRST AID PROC: W/TIGHT FITTING/CUFFED TUBE IS TO
BE PREFERRED OVER EMESIS. IF VISCOSITY IS >100 SUS AT 100 F, EMESIS
MAY BE INDUCED FOR LRG QTYS. ASPIR MAY CAUSE CHEM PNEUM/LIPOI D
PNEUM. SUBCUTANEOUS INJECTION REQS PROMPT SURGICAL DEBRIDEMENT. IF
NOT FAMILIAR W/TECHNIQUE, SEEK SKILLED (ING 5)

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:750F,399C
Vapor Pres:<3 X 10-4
Vapor Density:>1
Spec Gravity:0.89
Evaporation Rate & Reference:<1
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER LIQUID, SLIGHT SULFURIZED ODOR.
Percent Volatiles by Volume:SUPDAT

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:CO2 (CO UNDER INCOMPLETE COMBUSTION)

Disposal

Waste Disposal Methods:IT IS RESPONSIBILITY OF USER TO DETERMINE IF
MATL IS HAZ WASTE AT TIME OF DISP. CHECK BEFORE DISPOSING TO BE
SURE YOU ARE IN COMPLIANCE WITH ALL FEDERAL, STATE, AND LOCAL
REGULATIONS. CHEMTREC/RCRA EM ERGENCY NUMBER: 800-424-9346.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.