Product Identification

Product ID:ASP SERIES (DRY), 10000139
MSDS Date:04/25/1991
FSC:6505
NIIN:00N020244
MSDS Number: BLRLM

Responsible Party
ENGELHARD CORPORATION
70 WOOD AVENUE CN 28
ISELIN, NJ 08830-1526
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 201-321-5341

Cage: 23036

Contractor
ENGELHARD CORPORATION, SPECIALITY MINERALS AND COLORS
ISELIN, NJ 08830-0770 US

Telephone: 908-205-6933

Cage: 34316

Ingredients

KAOLIN

CAS: 1332-58-7

RTECS: GF1670500

Fraction By Weight: 100%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 2 MG/M3 TDUST; 9293

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE: MAY CAUSE MECHANICAL IRRITATION
IF EXPOSED TO LARGE AMOUNTS OF DUST. SKIN: NO ADVERSE EFFECTS
EXPECTED. INHAL: MAY CAUSE IRRITATION OF THE RESPIRATORY TRACT.
INGEST: NO ADVERSE EFFECTS EXPECTED. (CHRONIC) PROLONGED INHAL TO
EXCESSIVE LEVELS OF DUST MAY CAUSE BENIGN PNEUMOCONIOSIS, DUST IN
THE (SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: LUNG VISIBLE ON X-RAYS BUT WHICH
CAUSES NO SIGNIFICANT LOSS OF LUNG FUNCTION AND DOES NOT PROGRESS
TO FIBROSIS OR OTHER PROGRESSIVE LUNG DAMAGE. IN CASES OF EXTREME,
PROLONGED EXPOSURE, LUNG FUNCTION MAY BE IMPAIRED.
Medical Cond Aggravated by Exposure:ASTHMATIC CONDITIONS MAY WORSEN
FROM PROLONGED AND CONTINUOUS EXPOSURE TO DUST.

First Aid

First Aid:EYE: FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES. IF
IRRITATION DEVELOPS, CALL MD. SKIN: PROCEDURES NORMALLY NOT NEEDED.
IF SKIN CONTACT OCCURS FLUSH WITH PLENTY OF WATER. IF IRRITATION
DEVELOP S, CALL MD. INHAL: REMOVE TO FRESH AIR.IF BREATHING IS
DIFFICULT, GIVE OXYGEN. CALL MD. INGEST: PROCEDURES NORMALLY NOT
NEEDED. IF LARGE QUANTITIES ARE INGESTED, SEEK MEDICAL ADVICE.

Fire Fighting

Extinguishing Media:PRODUCT WILL NOT BURN. USE APPROPRIATE
EXTINGUISHING MEDIA TO EXTINGUISH COMBUSTIBLE MATERIALS STORED
NEAR-BY.
Fire Fighting Procedures:NO SPECIAL FIRE FIGHTING PROCEDURES ARE NEEDED
FOR THIS PRODUCT.
Unusual Fire/Explosion Hazard:THIS PRODUCT IS NOT A FIRE OR EXPLOSION
HAZARD.

Accidental Release

Spill Release Procedures:VACUUM OR SCOOP THE SPILLED MATERIAL INTO A
CONTAINER FOR RECLAMATION OR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:MATERIAL MAY BE SLIPPERY WHEN WET.
STORE IN A COOL, DRY LOCATION.
Other Precautions:AVOID BREATHING DUST. AVOID CONTACT WITH EYES. USE
WITH ADEQUATE VENTILATION.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED DUST MASK IF EXPOSURE
EXCEEDS TLV.
Ventilation:GENERAL; LOCAL EXHAUST VENTILATION AS NECESSARY TO CONTROL
ANY AIR CONTAMINANTS TO WITHIN THEIR TLVS DURING USE OF PROD.
Protective Gloves:NONE SPECIFIED BY MANUFACTURER.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

HCC:N1
Spec Gravity:2.58
Solubility in Water:INSOLUBLE
Appearance and Odor:WHITE POWDER; ODORLESS.

Stability

Stability Indicator/Materials to Avoid:YES
NONE EXPECTED.
Stability Condition to Avoid:NONE EXPECTED.
Hazardous Decomposition Products:NO HAZARDOUS DECOMPOSITION OR
BY-PRODUCTS ARE EXPECTED.

Disposal

Waste Disposal Methods:RAW (UNUSED) MATERIAL MAY BE DISPOSED OF IN A
SANITARY LANDFILL, HOWEVER, SPENT MATERIAL MAY BE CONTAMINATED AND
MAY REQUIRE SPECIAL DISPOSAL METHODS. CONSULT WITH APPROPRIATE
FEDERAL, STATE AND LOCAL REGULATORY AUTHORITIES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.