BLWXP - PRO-LINE PL-5 BURNT SIENNA, 790-240

  • MSDS: BLWXP
  • Manufacturer: ENGELHARD CORP
  • Product Name: PRO-LINE PL-5 BURNT SIENNA, 790-240
  • National Stock Number: 8010-00N022571
Product Identification

Product ID:PRO-LINE PL-5 BURNT SIENNA, 790-240
MSDS Date:06/20/1989
FSC:8010
NIIN:00N022571
MSDS Number: BLWXP

Responsible Party
ENGELHARD CORP
101 WOOD AVE
ISELIN, NJ 08830-0770
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 800-424-2015

Cage: ENGEL

Contractor
ENGELHARD CORPORATION, SPECIALITY MINERALS AND COLORS
ISELIN, NJ 08830-0770 US

Telephone: 908-205-6933

Cage: 34316

Ingredients

DIETHYLENE GLYCOL

CAS: 111-46-6

RTECS: ID5950000

Fraction By Weight: 19%


SURFACTANT

CAS: 68002-97-1

Fraction By Weight: 3%


LOCATION & THE TYPE OF DISPOSAL SELECTED.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE:CAUSES IRRIT & MAY CAUSE BURNS.
SKIN: PRLNGD/RPTD CONT MAY CAUSE IRRIT. TOX AMTS MAY BE ABSORBED
THRU THE SKIN. INHAL:AT ROOM TEMP, EXPOS TO VAPS/MIST ARE UNLIKELY.
HIGHER TEMPS MAY GENERATE VAPS/ MIST SUFFICIENT TO CAUSE ADVERSE
EFTS. INGEST:LGE AMTS OF DIETHYLENE GLYCOL MAY RSLT IN TOX EFTS ON
(SEE EFTS OF OVEREXP
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:THE CNS, GI TRACT, KIDNEY & LIVER. A
SINGLE LGE AMT MAY CAUSE SEV DAM/BE FATAL. NOTE:INHAL OF VAP/MIST
MAY BE SIGNIFICANT IF MATL IS HEATED OR AGITATED/SPRAYED.
CHRONIC:EXCESSIVE EXPOS BY ANY ROUTE MAY CAUSE DEGENERATION OF THE
KIDNEY &, TO A LESSER EXTENT, THE LIVER. IN ANIMAL STUDIES, (SEE
SUPP DATA)
Medical Cond Aggravated by Exposure:MAY ADVERSELY AFFECT EXISTING
MEDICAL CONDITIONS SUCH AS RENAL, HEPATIC & NEUROLOGICAL DISORDERS.

First Aid

First Aid:EYE/SKIN:IMMEDIATELY FLUSH EYES W/PLENTY OF WATER FOR AT
LEAST 15 MINS. CALL A MD. FLUSH SKIN W/WATER. INHAL:REMOVE TO FRESH
AIR. IF BREATHING IS DIFFICULT, GIVE OXYGEN. CALL A MD. INGEST:IF
SWALLOWED , INDUCE VOMITING IMMEDIATELY AS DIRECTED BY MEDICAL
PERSONNEL.

Fire Fighting

Extinguishing Media:USE WATER, CARBON DIOXIDE OR FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT A FIRE OR EXPLOSION HAZARD.

Accidental Release

Spill Release Procedures:CONTAIN SPILLAGE, SOAK UP W/INERT ABSORB &
SCOOP INTO CONTR FOR DISP. NOTIFICATION OF THE NATL RESPONSE CTR
(800-424- 8802) MAY BE REQD. REFER TO EPA, DOT & APPLIC STATE &
LOCAL REGS FOR CURRENT RESPO NSE INFO. IT IS RECOM THAT EACH (SEE
SUPP DATA)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:PROTECT FROM FREEZING. KEEP CONTAINER
CLOSED. KEEP AWAY FROM FOOD & FEED PRODUCTS. USE WITH ADEQUATE
VENTILATION.
Other Precautions:AVOID BREATHING MIST. AVOID CONTACT W/EYES, SKIN AND
CLOTHING.

Exposure Controls

Respiratory Protection:A NIOSH/MSHA APPROVED RESPIRATOR AS NECESSARY.
Ventilation:GENERAL; LOCAL EXHAUST AS NECESSARY TO CONTROL VAPORS &/OR
MIST.
Protective Gloves:RUBBER OR NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
EFTS OF OVEREXP:FORMATION OF BLADDER STONES & SECONDARY BLADDER CANCER
HAS BEEN OBSERVED. SPILL PROC:USER ESTABLISH A SPILL PREVENTION,
CONTROL & COUTERMEASURE PLAN (SPCC). SUCH PLAN SHOULD INCL PROCE
DURES APPLIC TO PROPER STOR, CONTROL & CLEAN-UP SPILLS, INCL REUSE
OR DISP AS APPROP.

Chemical Properties

HCC:N1
Vapor Pres:<17.5 @20C
Spec Gravity:1.94
pH:7.4
Evaporation Rate & Reference:SLOWER/WATER (BU AC=1)
Solubility in Water:39.6
Appearance and Odor:BROWN LIQUID; ODORLESS.

Stability

Stability Indicator/Materials to Avoid:YES
NONE EXPECTED.
Stability Condition to Avoid:NONE EXPECTED.
Hazardous Decomposition Products:NONE EXPECTED.

Disposal

Waste Disposal Methods:FED, STATE & LOCAL DISP LAWS & REGS WILL DETERM
THE PROPER WASTE DISP PROCEDURE. ALL WATER MATLS SHOULD BE REVIEWED
TO DETERM THE APPLIC HAZ (TESTING MAY BE NEC). DISP REQUIREMENTS
ARE DEPENDENT ON TH E HAZ CLASS & WILL VARY BY (SEE INGRED 3)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.