BMXRX - PRO-LINE PL-5 BURNT SIENNA
- MSDS: BMXRX
- Manufacturer: ENGELHARD CORP
- Product Name: PRO-LINE PL-5 BURNT SIENNA
- National Stock Number: 8010-00N028339
Product Identification
Product ID:PRO-LINE PL-5 BURNT SIENNA
MSDS Date:04/18/1991
FSC:8010
NIIN:00N028339
MSDS Number: BMXRX
Responsible Party
ISELIN, NJ 08830-0770
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 502-775-7288
Cage: 03557
Contractor
Telephone: 502-775-7288
Cage: 03557
Ingredients
DIETHYLENE GLYCOL
CAS: 111-46-6
RTECS: ID5950000
Fraction By Weight: 19%
SURFACTANT(S) - TYPE NOT SPECIFIED
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE:CAUSES IRRIT & MAY CAUSE BURNS.
SKIN:PRLNGD/RPTD CONTACT MAY CAUSE IRRIT. TOX AMTS MAY BE ABSORBED
THRU SKIN. INHAL:AT ROOM TEMPS, EXPOS TO VAPS OR MISTS ARE
UNLIKELY. HIGHER TEMPS MAY GENERATE VA PS OR MISTS SUFFICIENT TO
CAUSE ADVERSEEFTS. INGEST OF LGE AMTS OF DIETHYLENE GLYCOL MAY RSLT
IN TOX (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:EFTS ON CNS, GI TRACT, KIDNEY & LIVER.
SINGLE LGE AMT MAY CAUSE SEVERE DMG OR BE FATAL. LAB ANIMAL STUDIES
INDICATE THAT GLYCOL ETHERS MAY CAUSE REPROD EFTS. INHAL OF VAP
&/OR MIST MAY BE SIG NIFICANT IF MATL IS HEATED OR
AGITATED/SPRAYED. CHRONIC:EXCESS EXPOS BY ANY ROUTE MAY CAUSE
DEGENERATION OF (SUPP DATA)
Medical Cond Aggravated by Exposure:MAY ADVERSELY AFFECT EXISTING
MEDICAL CONDITIONS SUCH AS RENAL, HEPATIC AND NEUROLOGICAL
DISORDERS.
First Aid
First Aid:EYE:IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR AT LEAST 15
MINUTES. CALL MD. SKIN:FLUSH WITH PLENTY OF WATER. IF IRRITATION
PERSISTS, CALL MD. INHAL:MOVE TO FRESH AIR. IF BREATHING DFCLT,
GIVE O*2. CA LL MD. INGEST:IMMEDIATELY GIVE 2 GLASSES OF WATER &
CALL MD, HOSPITAL EMERGENCY ROOM, OR POISON CONTROL CENTER FOR A
WAY TO INDUCE VOMITING. NEVER GIVE ANYTHING BY MOUTH TO AN
UNCONSCIOUS PERSON.
Fire Fighting
Extinguishing Media:USE WATER, CARBON DIOXIDE OR FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT A FIRE OR EXPLOSION HAZARD.
Accidental Release
Spill Release Procedures:CONTAIN SPILLAGE, SOAK UP WITH INERT ABSORBENT
& SCOOP INTO CONTAINERR FOR DISPOSAL. NOTIFICATION OF NATIONAL
RESPONSE CENTER (800-424-8802) MAY BE REQUIRED. REFER TO EPA, DOT &
APPLICABLE STATE & LOC AL REGULATIONS FOR CURRENT RESPONSE
INFORMATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP CONTAINER CLOSED. PROTECT FROM
FREEZING.
Other Precautions:KEEP AWAY FROM FOOD AND FEED PRODUCTS. AVOID
BREATHING MIST. USE WITH ADEQUATE VENTILATION. AVOID CONTACT WITH
EYES, SKIN AND CLOTHING.
Exposure Controls
Respiratory Protection:A NIOSH/MSHA APPROVED RESPIRATOR AS NECESSARY.
Ventilation:GENERAL; LOCAL EXHAUST AS NECESSARY TO CONTROL VAPORS
AND/OR MISTS.
Protective Gloves:RUBBER OR NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
EFTS OF OVEREXP:KIDNEY &, TO LESSER EXTENT, LIVER. IN ANIMAL STUDIES,
FORMATION OF BLADDER STONES/SECONDARY BLADDER CANCER HAS BEEN
OBSERVED. OVEREXP MAY CAUSE GI TRACT/CNS/KIDNEY FUNCTION
DISTURBANCE S. MAY CAUSE EYE, SKIN/RESP IRRIT. HARMFUL IF LGE AMTS
INGEST. WASTE DISP METH:WASTE MATLS ARE AMENABLE TO RECYCLE/REUSE
Chemical Properties
Vapor Pres:<17.5 @20C
Spec Gravity:1.92 (TYPICAL)
pH:7.4
Evaporation Rate & Reference:SLOWER THAN H*20(BU AC=1)
Solubility in Water:39.6
Appearance and Odor:ODORLESS BROWN LIQUID
Stability
Stability Indicator/Materials to Avoid:YES
NONE EXPECTED.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE EXPECTED.
Disposal
Waste Disposal Methods:FED, STATE & LOC DISP LAWS & REGS WILL DETERMINE
PROPER WASTE DISP PROC. ALL WASTE MATLS SHOULD BE REVIEWED TO
DETERMINE APPLIC HAZS (TESTING MAY BE NEC). DISP REQS ARE DEPENDENT
OF HAZ CLASS & WILL V ARY BY LOC & TYPE OF DISP SELECTED. SOME
(SUPDAT)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.