BMZGG - 11620-014, RAID ANT AND ROACH KILLER (PRESS
- MSDS: BMZGG
- Manufacturer: S C JOHNSON WAX
- Product Name: 11620-014, RAID ANT AND ROACH KILLER (PRESS
- National Stock Number: 6840-00-960-7248
Product Identification
Product ID:11620-014, RAID ANT AND ROACH KILLER (PRESS
MSDS Date:03/23/1988
FSC:6840
NIIN:00-960-7248
MSDS Number: BMZGG
Responsible Party
RACINE, WI 53403-5011
US
Emergency Phone: 414-631-2000
Info Phone: 414-631-2777
Preparer: TERRY A. MEYERS
Cage: GO109
Contractor
Telephone: 800-725-6737
Cage: 32204
Ingredients
KEROSENE (PETROLEUM), HYDROTREATED; (HYDROCARBON SOLVENT)
CAS: 64742-47-8
RTECS: OA5504000
Fraction By Weight: 85-95%
CARBON DIOXIDE
CAS: 124-38-9
RTECS: FF6400000
Fraction By Weight: 1-4%
OSHA PEL 5000 PPM
ACGIH TLV: 5000PPM/30000STEL;93
TOLUENE, ALPHA-(2-(2-BUTOXYETHOXY)ETHOXY)-4,5-
CAS: 51-03-6
RTECS: XS8050000
Fraction By Weight: 1.05%
OSHA PEL N/K
ACGIH TLV: N/K
PROPANE
CAS: 74-98-6
RTECS: TX2275000
Fraction By Weight: 3-7%
OSHA PEL 1000 PPM
ACGIH TLV: ASPHYXIANT
PROPANE, 2-METHYL-; (ISOBUTANE)
CAS: 75-28-5
RTECS: TZ4300000
Fraction By Weight: 20-30%
OSHA PEL N/K
ACGIH TLV: N/K
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 65-75%
OSHA PEL N/K
ACGIH TLV: N/K
NOT AVAILABLE. THEORETICAL
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SEE SIGNS & SYMPTOMS (OVEREXPOSURE).
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:DIRECT CONT OF PROD W/EYES CAN CAUSE IRRIT.
PRLNGD/RPTD CONT OF PROD W/SKIN MAY CAUSE IRRIT. PROD MAY CAUSE
DISTRESS & ILLNESS IF TAKEN INTERNALLY. IF TAKEN INTERNALLY, ASPIR
OF LIQ PROD CAN CAUSE CHE M PNEUM. PROD SPRAY MIST, FOG/VAP MAY
CAUSE IRRIT TO NOSE, THROAT & LUNGS IF ADEQ VENT IS NOT EMPLOYED.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MIN. IF IRRIT
PERSISTS, SEEK MEDICAL AID. SKIN: REMOVE WITH SOAP & WATER. INGEST:
IF PROD IS SWALLOWED, DRINK LRG AMTS OF WATER OR MILK AND SEEK
MEDICAL AID. INH AL: IF MIST, FOG OR VAPS CAUSE DISCOMFORT, REMOVE
TO FRESH AIR & VENT AREA. IF DISCOMFORT PERSISTS, SEEK MEDICAL AID.
NOTE TO MD: ATROPINE IS ANTIDOTAL & SHOULD BE ADMIN ONLY AFTER SYMP
APPEAR.
Fire Fighting
Flash Point Method:TCC
Flash Point:140F,60C
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
.NORMAL FIREFIGHTING PROC MAY BE USED.FIGHT FIRE FROM MAX
DISTANCE/PROT AREA.COOL & USE CAUTION (SUPP DATA)
Unusual Fire/Explosion Hazard:LIQUID RUN-OFF TO SEWERS MAY CREATE
FIRE/EXPLOSION HAZARD.
Accidental Release
Spill Release Procedures:ELIMINATE ALL IGNITION SOURCES. RINSE AFFECTED
AREA THOROUGHLY WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP OUT OF REACH OF CHILDREN.
CONTAINERS UNDER PRESSURE. NEVER SET CNTNR ANYWHERE WHERE TEMP WILL
EXCEED 120F.
Other Precautions:HARMFUL IF SWALLOWED, INHALED OR ABSORBED THRU SKIN.
AVOID BREATHING SPRAY MIST. DO NOT APPLY TO HUMANS. AVOID CONTACT
WITH SKIN, EYES OR CLOTHING. DO NOT ALLOW CHILDREN IN TREATED AREAS
UNTIL DRY. DO NOT USE NEAR OPEN FLAME.
Exposure Controls
Respiratory Protection:NO SPECIAL REQUIREMENTS UNDER NORMAL USE
CONDITIONS. IF MISTS/VAPORS ARE NOT ADEQUATELY CONTROLLED BY LOCAL
VENTILATION, USE APPROPRIATE NIOSH/MSHA APPROVED RESPIRATORY
PROTECTION TO PREVENT OVEREXPOS URES.
Ventilation:GENERAL ROOM VENT IS NORMALLY ADEQ. SUBSTANTIAL AMTS OF
MISTS/VAPS CAN BE CONTROLLED W/LOCAL EXHST VENT/RESP PROT.
Protective Gloves:RUBBER.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:USE GOOD PERSONAL HYGIENE PRACTICES. WHERE
GROSS EYE/SKIN CONT MAY BE PROBLEM, WEAR/USE APPROP PROT EQUIPMENT.
Work Hygienic Practices:WASH HANDS THOROUGHLY WITH SOAP AND WATER AFTER
USE AND BEFORE EATING OR SMOKING.
Supplemental Safety and Health
FIRE FIGHT PROC:WHEN APPROACHING OR HANDLING FIRE-EXPOSED CONTAINERS.
Chemical Properties
Spec Gravity:0.79
Solubility in Water:NEGLIGIBLE
Appearance and Odor:DISPENSED AS A SPRAY WITH NAPHTHA ODOR.
Percent Volatiles by Volume:>99
Stability
Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:WHEN EXPOSED TO FIRE, PRODUCES NORMAL
PRODUCTS OF COMBUSTION.
Disposal
Waste Disposal Methods:DISPOSE OF AEROSOL CAN BY WRAPPING & PLACING IN
TRASH. DO NOT PUNCTURE OR BURN CONTAINER. DISPOSE OF SPILLED
RESIDUES AND MULTIPLE UNITS IN ACCORDANCE WITH ALL FEDERAL, STATE
REGULATIONS AND LOCAL ORD INANCES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.