BNQPB - 32-3083, VCR HEAD CLEANER

  • MSDS: BNQPB
  • Manufacturer: G C THORSEN
  • Product Name: 32-3083, VCR HEAD CLEANER
  • National Stock Number: 5835-00N030302
Product Identification

Product ID:32-3083, VCR HEAD CLEANER
MSDS Date:07/03/1991
FSC:5835
NIIN:00N030302
MSDS Number: BNQPB

Responsible Party
G C THORSEN
1801 MORGAN ST
ROCKFORD, IL 61105
US

Emergency Phone: 815-968-9661;800-424-9300(CHEMTREC)

Info Phone: 815-968-9661

Preparer: V. HAGEMAN

Cage: THORS

Contractor
GC THORSEN
ROCKFORD, IL 61105 US

Telephone: 815-968-9661

Cage: 72653

Ingredients

ETHANE, 1,1,2-TRICHLORO-1,2,2-TRIFLUORO-;

CAS: 76-13-1

RTECS: KJ4000000

Fraction By Weight: 100%

OSHA PEL 1000 PPM;1250 STEL

ACGIH TLV: 1000 PPM;1250 STEL

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: LIGHT HEADEDNESS, SHORTNESS OF
BREATH, NARCOSIS, CARDIAC IRREGULARITIES, UNCON OR DEATH. SKIN:
REPEATED CONTACT MAY CAUSE DEFATTING AND IRRIT. EYE: CONTACT WITH
LIQUID CAUSES DISCOMFORT (NO EXT ENDED EFFECT). CHLOROFLUOROCARBON
MATLSHAVE PRODUCED SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB
ANIMALS (EFTS OF OVEREX
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: AND COULD A SIMILAR EFFECT IN HUMANS.
ADRENOMIMETICS (E.G. EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR
LIFE-SUSTAINING USES IN INDIVIDUALS ACUTELY OR CHRONICALLY EXPOSED
TO CFC'S .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MIN. CONSULT
PHYSICIAN. SKIN: WASH WITH WATER. CONSULT PHYSICIAN IF IRRITATION
PERSISTS. INHAL: REMOVE TO FRESH AIR, OXYGEN, ARTIFICIAL
RESPIRATION IF NECESSARY. CONSULT PHYSICIAN. INGEST: NOT LIKELY TO
BE HAZARDOUS. DO NOT INDUCE VOMITING-CONSULT PHYSICIAN.

Fire Fighting

Extinguishing Media:CO2, H2O, H2O FOG, CHEMICAL FOAM, DRY CHEMICAL.
Fire Fighting Procedures:DRUMS MAY RUPTURE-DECOMPOSITION MAY OCCUR.
WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE. THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE CHLORIDES, FLUORIDES AND PHOSGENE .

Accidental Release

Spill Release Procedures:VENTILATE AREA WELL. DIKE SPILL OR LEAK.
COLLECT WITH AN ABSORBENT MATERIAL AND STORE IN A CONTAINER FOR
DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN A CLEAN, DRY AREA. AVOID HIGH
TEMPERATURES AND IGNITION SOURCES.
Other Precautions:NONE. NO SMOKING IN AREA OF USE. DO NOT USE IN THE
GENERAL VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT
AND/OR UV RADIATION MAY CAUSE THE FORMATION OF CHLORIDES, FLUORIDES
AND/OR PHOSGEN E .

Exposure Controls

Respiratory Protection:NOT NORMALLY REQUIRED. NIOSH/MSHA APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST. MECHANICAL AS REQUIRED TO MEET TLV'S.
Protective Gloves:BUTYL GLOVES IF PRLNGD/RPTD EXPOSURE
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:117F,47C
Vapor Pres:334
Vapor Density:65
Spec Gravity:1.57 @ 77F
Evaporation Rate & Reference:0.1 (CCI4=1)
Solubility in Water:0.027 @ 77F
Appearance and Odor:COLORLESS LIQUID-SLIGHT ETHEREAL ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
ALKALI,ALK. EARTH METALS. (POWDER AL, ZN, BE, ETC.)
Stability Condition to Avoid:HIGH TEMPERATURES AND IGNITION SOURCES.
Hazardous Decomposition Products:AT HIGH TEMPERATURES, CHEMICAL MAY
FORM HYDROCHLORIC & HYDROFLUORIC ACIDS, & CARBOXYL HALIDES.
PHOSGENE .

Disposal

Waste Disposal Methods:DO NOT FLUSH INTO SEWERS. DISPOSE AT A LICENSED
WASTE DISPOSAL FACILITY. DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their