BNRLP - I-40B, POLYOL

  • MSDS: BNRLP
  • Manufacturer: SEALED AIR CORP
  • Product Name: I-40B, POLYOL
  • National Stock Number: 9330-01-322-0694
Product Identification

Product ID:I-40B, POLYOL
MSDS Date:03/01/1987
FSC:9330
NIIN:01-322-0694
MSDS Number: BNRLP

Responsible Party
SEALED AIR CORP
OLD SHERMAN TPKE
DANBURY, CT 06810
US

Emergency Phone: 203-792-2360;800-424-9300(CHEMTREC)

Info Phone: 203-792-2360

Preparer: LYNN G. WERNER

Cage: 51614

Contractor
SEALED AIR CORP INSTAPAK DIVISION
DANBURY, CT 06810 US

Telephone: 203-791-3500/800-424-9300(CHEMTREC)

Cage: 51614

Ingredients

METHANE, TRICHLOROFLUORO-; (TRICHLOROMONOFLUOROMETHANE)

CAS: 75-69-4

RTECS: PB6125000

Fraction By Weight: 15%

OSHA PEL 1000 PPM

ACGIH TLV: C, 1000 PPM; 9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ETHANOL, 2,2'-IMINODI-; (DIETHANOLAMINE) (SARA III)

CAS: 111-42-2

RTECS: KL2975000

Fraction By Weight: 1.5%

OSHA PEL 3 PPM

ACGIH TLV: 3 PPM

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHLOROFLUOROCARBON MATLS HAVE PRODUCED
SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE
SIMILAR EFT IN HUMANS. ADRENOMETICS (E.G., EPINEPHRINE) MAY BE
CONTRAINDICATED EXCEPT FOR LIFE-SU STAINING USES IN HUMANS
ACUTELY/CHRONICALLY EXPOSED TO CFC'S . INHAL:VAP MAY BE IRRIT IF
HOT. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:SKIN:REPEATED CONTACT MAY BE
IRRITATING. EYE:CAN CAUSE EYE IRRITATION. PERMANENT CORNEAL INJURY
IS UNLIKELY. INGEST:INGESTION IS UNLIKELY. LARGE QUANTITIES COULD
CAUSE IRRITATION OF MOUTH AND STOMACH.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:REMOVE TO UNCONTAMINATED AREA, ADMINISTER O*2 IF
NECESSARY. CONSULT MD. SKIN:WASH AREA THOROUGHLY WITH SOAP AND
WATER. LAUNDER CLOTHING BEFORE REUSE. EYE:FLUSH WITH WATER FOR AT
LEAST 15 MINUTES , HOLDING LIDS OPEN WITH FINGERS. CONSULT MD.
INGEST:DRINK WATER TO DILUTE. CONSULT MD. TREATMENT IS SYMPTOMATIC.

Fire Fighting

Flash Point Method:PMCC
Flash Point:250F,121C
Extinguishing Media:CARBON DIOXIDE, CHEMICAL FOAM, DRY CHEMICAL, WATER
SPRAY.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD PRESS DEMAND SCBA &
FULL PROT EQUIP . OVER-HEATING OF CONTAINERS CAN LEAD TO RUPTURE
DUE TO LOW BOILING TRICHLOROFLUOROMETHANE.
Unusual Fire/Explosion Hazard:THERM DECOMP PRODS MAY INCL CHLORIDES,
FLUORIDES & PHOSGENE . PROD AS SUPPLIED DOES NOT HAVE DETERMINABLE
FLASH POINT. INFO PROVIDED WAS (SUPP DATA)

Accidental Release

Spill Release Procedures:ABSORB ON LOOSE, ABSORBENT, NON-BIODEGRADABLE
MATERIAL. PROVIDE SUFFICIENT VENTILATION TO MAINTAIN FLUOROCARBON
LEVEL BELOW TLV OF 1000 PPM. EYE AND SKIN PROTECTION SHOULD BE
WORN.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORAGE TEMP:MIN 35F/2C, MAX 110F/43C.
AVERAGE SHELF LIFE:12 MONTHS. STORE IN COOL AREA. CNTNRS >80F/27C
WILL BE UNDER PRESS & MUST BE OPENED W/CARE.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES/HOT SURF. HEAT AND/OR UV RADIA
MAY CAUSE FORMATION OF CHLORIDES, FLUORIDES AND/OR PHOSGENE .

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED CARTRIDGE RESPIRATOR FOR
ORGANIC VAPORS IF CONDITIONS REQUIRE. PRESENCE OF ADEQUATE
BREATHING OXYGEN MUST BE ASSURED.
Ventilation:SUFFICIENT TO MAINTAIN FLUORCARBON VAPORS BELOW 1000 PPM
TLV-C.
Protective Gloves:CHEMICAL RESISTANT RUBBER/PLASTIC.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:SAFETY SHOWER AND EYE WASH STATION SHOULD BE
AVAILABLE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ: OBTAINED ON MATERIAL W/O WATER & TRICHLOROMONOFLUOROMETHANE.

Chemical Properties

Boiling Pt:B.P. Text:>100F,>38C
Melt/Freeze Pt:M.P/F.P Text:20F,-18C
Vapor Pres:900 @ 100F
Vapor Density:4
Spec Gravity:1.09 @ 25C
Solubility in Water:SOLUBLE
Appearance and Odor:CLEAR, STRAW COLORED LIQUID W/SLIGHT FLUOROCARBON
ODOR.
Percent Volatiles by Volume:15

Stability

Stability Indicator/Materials to Avoid:YES
ISOCYANATES; UNLESS MIXED AT PROPER RATIO.
Stability Condition to Avoid:VAPOR CONTACT WITH OPEN FLAME.
Hazardous Decomposition Products:CHLORIDES, FLUORIDES AND PHOSGENE . BY
FIRE/EXTREME HEAT, CO*X, NO*X, HCL & HYDROGEN FLUORIDE (CORROSIVE)

Disposal

Waste Disposal Methods:INCINERATE OR DISPOSE OF IN ACCORDANCE WITH
EXISTING FEDERAL, STATE AND LOCAL ENVIRONMENTAL CONTROL
REGULATIONS. ALSO SEE "RECOMMENDATIONS FOR SAFE USE AND HANDLING OF
INSTAPAK FOAM-IN-PLACE CHEMICALS " BULLETIN.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.