BPDPN - 14-012, DURA CLAD EPOXY MODIFIED ENAMEL (SU
- MSDS: BPDPN
- Manufacturer: DURON INC
- Product Name: 14-012, DURA CLAD EPOXY MODIFIED ENAMEL (SU
- National Stock Number: 8010-00N030087
Product Identification
Product ID:14-012, DURA CLAD EPOXY MODIFIED ENAMEL (SU
MSDS Date:07/12/1990
FSC:8010
NIIN:00N030087
MSDS Number: BPDPN
Responsible Party
BELTSVILLE, MD 20706-2297
US
Emergency Phone: 800-228-5636
Info Phone: 301-837-4600
Preparer: THOMAS BRICE
Cage: 75734
Contractor
Telephone: 301-937-4600
Cage: 55652
Ingredients
HLTH STUDIES HAVE SHOWN MANY PETRO
RTECS: 9999999ZZ
HUMAN HLTH RISKS WHICH MAY VARY FROM PERS TO PERS.
RTECS: 9999999ZZ
MINIMIZED. LAB ANIMAL STUDIES HAVE SHOWN PRLNG/RPTD
RTECS: 9999999ZZ
BOILING RANGE AS PROD CAN PRDCE ADVERSE KIDNEY EFTS
RTECS: 9999999ZZ
EVIDENCE OF LUNG CANCER (MALIGNANT TUMORS) IN 1 OUT
RTECS: 9999999ZZ
WERE EXPOSED TO 250 MG/M3 TITANIUM DIOXIDE
RTECS: 9999999ZZ
NOT INDUCE VOMIT.IF VOMIT OCCURS
RTECS: 9999999ZZ
LUNGS. GET MEDICAL ATTENTION.
RTECS: 9999999ZZ
BY DIKING/COMPOUNDING. ASSURE CONFORMITY
RTECS: 9999999ZZ
VOLATILE, COMBUSTIBLE VAPS FROM ABSORBED MATL.
RTECS: 9999999ZZ
CALCIUM CARBONATE
CAS: 1317-65-3
RTECS: EV9580000
Fraction By Weight: <7.9%
OSHA PEL 15MG/M3 TDUST;5RDUST
ACGIH TLV: 10 MG/M3 TDUST
CLAY; (KAOLIN)
CAS: 1332-58-7
RTECS: GF1670500
Fraction By Weight: 2-6.8%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 2 MG/M3 TDUST; 9293
STODDARD SOLVENT
CAS: 8052-41-3
RTECS: WJ8925000
Fraction By Weight: 36.6-43%
OSHA PEL 500 PPM
ACGIH TLV: 100 PPM; 9293
SYNTHETIC RESIN; (SYNTHETIC RESIN COMPLEX)
Fraction By Weight: 31-36.2%
TITANIUM OXIDE; (TITANIUM DIOXIDE). PERCENTAGE
CAS: 13463-67-7
RTECS: XR2275000
Fraction By Weight: SEE ING
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
WELDING/CUTTING TORCH ON OR NEAR CONTAINER (EVEN
RTECS: 9999999ZZ
RATS. HOWEVER, THESE EFTS WERE NOT OBSERVED IN
RTECS: 9999999ZZ
LIMITED STUDIES W/OTHER ANIMAL SPECIES. ADDITIONALLY,
RTECS: 9999999ZZ
EVIDENCE OF SUCH EFTS @ NORM OCCUP LVLS.IT IS
RTECS: 9999999ZZ
RATS HAVE SIGNIFICANT IMPLICATIONS FOR HUMANS @/<
RTECS: 9999999ZZ
CAN CAUSE SEV
RTECS: 9999999ZZ
CAUSE GI IRRIT, NAUS, VOMIT & DIARR.ASPIR OF MATL
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:LD50: (ORAL, RAT) >5 G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:EXCESSIVE INHAL OF VAPS CAN
CAUSE NASAL & RESP IRRIT, DIZZ, WEAKNESS, FATG, NAUS, HDCH. HIGH
VAP CONC MAY RSLT IN CNS DEPRESS. LAB ANIMAL STUDIES HAVE SHOWN
THAT PRLNGD & RPTD INHAL EXPOS TO LIG HT HYDROCARBON VAPS IN THE
SAME NAPHTHABOILING RANGE AS PROD CAN PRDCE ADVERSE KIDNEY EFTS IN
MALE (ING 7)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HIGH VAPOR CONCENTRATIONS (GREATER THAN
APPROXIMATELY 1000 PPM) ARE IRRITATING TO THE EYES AND THE
RESPIRATORY TRACT. MAY CAUSE HEADACHES AND DIZZINESS, ARE
ANESTHETIC, AND MAY HAVE OTHER CENTRAL NERV OUS SYSTEM EFFECTS
INCLUDING DEATH.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR & PROVIDE O*2 IF BRTHG IS DFCLT. IF
BRTHG STOPS, BEGIN ARTF RESP & SEEK IMMED MED ATTN. SKIN:REMOVE
CONTMD CLTHG/SHOES. FLUSH W/WATER. FOLLOW BY WASHING W/SOAP &
WATER. IF IR RIT OCCURS, GET MED ATTN. DO NOT REUSE CLTHG UNTIL
CLEANED. EYES:IF SPLASHED INTO EYES, FLUSH W/CLEAR WATER FOR @
LEAST 15 MIN/UNTIL IRRIT SUBSIDES. IF IRRIT PERSISTS, CALL MD.
INGEST: DO (ING 19)
Fire Fighting
Flash Point Method:TCC
Flash Point:104F,40C
Lower Limits:0.9%
Upper Limits:6%
Extinguishing Media:USE DRY CHEM, FOAM/CO2. WATER MAY BE INEFTIVE, BUT
WATER SHLD BE USED TO KEEP FIRE-EXPOS CNTNRS COOL. IF (SUPP DATA)
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER MAY BE UNSUITABLE AS AN EXTING MEDIA, BUT HELPFUL IN
KEEPING ADJACENT CNTNRS COOL. AVOID (SUPP DATA)
Unusual Fire/Explosion Hazard:VAPS ARE HVR THAN AIR & MAY TRAVEL ALONG
GROUND/BE MOVED BY VENT & IGNITED BY HEAT, PILOT LIGHTS, OTHER
FLAME & IGNIT SOURCES @ LOCATIONS DISTANT (SUPP DATA)
Accidental Release
Spill Release Procedures:ELIMINATE ALL IGNIT SOURCES (FLARES, FLAMES
INCLUDING PILOT LIGHTS, ELEC SPARKS). RECOVER FREE PROD. ADD SAND,
EARTH OR OTHER SUITABLE ABSORB TO SPILL AREA. MINIMIZE SKIN CONT.
VENT CONFINED SPACES. K EEP PROD OUT OF SEWERS & WATERCOURSES (ING
21)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT EAT, DRINK OR SMOKE WHILE USING
THIS PRODUCT.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:THE USE OF RESPIRATORY PROTECTION DEPENDS ON
VAPOR CONCENTRATION ABOVE THE TIME WEIGHTED TLV; USE NIOSH/MSHA
APPROVED RESPIRATOR.
Ventilation:PROVIDE SUFFICIENT MECHANICAL (GENERAL) AND/OR LOCAL
EXHAUST VENTILATION TO MAINTAIN EXPOSURE BELOW TLV.
Protective Gloves:CHEMICAL RESISTANT PLASTIC/RUB GLOVES.
Eye Protection:CHEM WORK GOG/FULL LGTH FSHLD .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:THOROUGHLY WASH HANDS BEFORE EATING OR SMOKING.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO: PAINT DEEP BASE. EXTING MEDIA:LEAK/SPILL HAS
IGNITED, USE WATER SPRAY TO DISPERSE VAPS & TO PROTECT MEN
ATTEMPTING TO STOP LEAK. MINIMIZE BRTHG GASES, VAPS, FUMES/DECOMP
PROD S. FIRE FIGHT PROC: SPREADING BURNING LIQ W/WATER USED FOR
COOLING. EXPLO HAZ:FROM HANDLING POINT. NEVER USE (ING 6)
Chemical Properties
HCC:F4
Vapor Pres:2 @ 20F
Vapor Density:4.9
Evaporation Rate & Reference:0.1 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE: <0.1
Appearance and Odor:VISCOUS LIQUID.
Stability
Stability Indicator/Materials to Avoid:YES
THIS PRODUCT IS INCOMPATABLE WITH STRONG OXIDIZING AGENTS, STRONG ACIDS
OR BASES AND SELECTED AMINES.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL DECOMPOSITION IN THE PRESENCE
OF AIR MAY YIELD CARBON MONOXIDE AND/OR CARBON DIOXIDE.
Disposal
Waste Disposal Methods:DISPOSE OF PRODUCT I/A/W APPLICABLE LOCAL,
COUNTY, STATE AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,