BPDPP - 14-907, DURA CLAD EPOXY MODIFIED ENAMEL (SU

  • MSDS: BPDPP
  • Manufacturer: DURON INC
  • Product Name: 14-907, DURA CLAD EPOXY MODIFIED ENAMEL (SU
  • National Stock Number: 8010-00N030088
Product Identification

Product ID:14-907, DURA CLAD EPOXY MODIFIED ENAMEL (SU
MSDS Date:07/12/1990
FSC:8010
NIIN:00N030088
MSDS Number: BPDPP

Responsible Party
DURON INC
10406 TUCKER ST
BELTSVILLE, MD 20706-2297
US

Emergency Phone: 800-228-5636

Info Phone: 301-937-4600

Preparer: THOMAS BRICE

Cage: 75734

Contractor
DURON INC AMERICAN DIV
BELTSVILLE, MD 20705-2201 US

Telephone: 301-937-4600

Cage: 55652

Ingredients

SIGNIFICANT IMPLICATIONS FOR HUMANS @/BELOW

RTECS: 9999999ZZ


CAN CAUSE SEV

RTECS: 9999999ZZ


GI IRRIT, NAUS, VOMIT & DIARR. ASPIR OF MATL INTO

RTECS: 9999999ZZ


CONCS (>1000PPM) ARE IRRITATING TO EYES/RESP TRACT,

RTECS: 9999999ZZ


EFTS INCL DEATH. IN AN INHAL STUDY, EVIDENCE OF LUNG

RTECS: 9999999ZZ


MALE RATS & 13 OUT OF 74 FEMALE RATS AFTER THEY WERE

RTECS: 9999999ZZ


OCCURS SPONT, KEEP HEAD BELOW HIPS TO PVNT

RTECS: 9999999ZZ


IMPOUNDING. ASSURE CONFORMITY W/APPLIC FED, ST &

RTECS: 9999999ZZ


COMBUSTIBLE VAPORS FROM ABSORBED MATERIAL.

RTECS: 9999999ZZ


CALCIUM CARBONATE

CAS: 1317-65-3

RTECS: EV9580000

Fraction By Weight: <7.9%

OSHA PEL 15MG/M3 TDUST;5RDUST

ACGIH TLV: 10 MG/M3 TDUST


CLAY (KAOLIN)

CAS: 1332-58-7

RTECS: GF1670500

Fraction By Weight: 2.0-6.8%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 2 MG/M3 TDUST; 9293


STODDARD SOLVENT

CAS: 8052-41-3

RTECS: WJ8925000

Fraction By Weight: 36.6-40%

OSHA PEL 500 PPM

ACGIH TLV: 100 PPM; 9293


SYNTHETIC RESIN; (SYNTHETIC RESIN COMPLEX)

Fraction By Weight: 31.0-32%


3.6-27.1

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: INGRED

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


CONTR (EVEN EMPTY) BECAUSE VAPORS MAY IGNITE.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50:(ORAL,RAT)>5 G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHAL:EXCESS INHAL OF VAP CAN CAUSE
NASAL & RESP IRRIT, DIZZ, WEAK, FATG, NAUS, HDCH. HIGH VAP CONC MAY
RSLT IN CNS DEPRESS. LAB ANIMAL STUDIES HAVE SHOWN THAT PRLNG &
RPTD INHAL EXPOS TO LIGHT HYDROC ARBON VAP IN SAME NAPHTHA BOILING
RANGEAS PROD CAN PRDCE ADVERSE KIDNEY EFTS IN MALE RATS. HOWEVER,
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:CRYSTALLINE SILICA: GROUP 2A (IARC),
GROUP 2(NTP)
Effects of Overexposure:HLTH HAZ: THESE EFTS WERE NOT OBSERVED IN
SIMILAR STUDIES W/FEMALE RATS & MALE MICE & IN LIM STUDIES W/OTHER
ANIMAL SPECIES. ADDTNL, IN NUMBER OF HUMAN STUDIES, THERE WAS NO
CLINICAL EVIDENCE OF SUCH EFTS @ NORM OCCUP LEVELS. IT IS
THEREFORE HIGHLY UNLIKELY THAT KIDNEY EFTS OBSERVED IN MALE RATS
HAVE (ING 7)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR & PROVIDE O*2 IF BRTHG IS DFCLT.
IF BRTHG STOPS, BEGIN ARTF RESP & SEEK IMMED MED ATTN. SKIN: REMOVE
CONTAMD CLTHG/SHOES. FLUSH W/H*2O. FOLLOW BY WASH W/SOAP/H*2O. IF
IRRIT OCCURS, GET MED ATTN. DO NOT REUSE CLTHG UNTIL CLEANED.
EYES: FLUSH W/CLEAN H*2O FOR @ LST 15 MIN/UNTIL IRRIT SUBSIDES. IF
IRRIT PERSISTS, CALL PHYS. INGEST:DO NOT INDUCE VOMIT. IF VOMIT
(ING 13)

Fire Fighting

Flash Point Method:TCC
Flash Point:104F,40C
Lower Limits:0.95
Upper Limits:6%
Extinguishing Media:USE DRY CHEM, FOAM/CO2. H2O MAY BE INEFTIVE, BUT
H2O SHOULD BE USED TO KEEP FIRE-EXPOS CONTR COOL. IF (SUPP DATA)
Fire Fighting Procedures:NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP. H2O
MAY BE UNSUITABLE AS AN EXTING MEDIA, BUT HELPFUL IN KEEPING
ADJACENT CONTR COOL. AVOID (SUPP DATA)
Unusual Fire/Explosion Hazard:VAP ARE HVR/AIR & MAY TRAVEL ALONG
GROUND/BE MOVED BY VENT & IGNITED BY HEAT/PILOT LIGHTS, OTHER FLAME
& IGNIT SOURCES @ LOCATIONS DISTANT FROM HNDLG(SUPP DATA)

Accidental Release

Spill Release Procedures:ELIMINATE ALL IGNIT SOURCES (FLARES, FLAMES
INCL PILOT LIGHTS, ELEC SPARKS). RECOVER FREE PROD. ADD SAND,
EARTH/OTHER SUITABLE ABSORB TO SPILL AREA. MINIMIZE SKIN CONT. VENT
CONFINED SPACES. KEEP PRO D OUT OF SEWERS & WATERCOURSES BY DIKING/
(ING 14)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:THE USE OF RESPIRATORY PROTECTION DEPENDS ON
VAPOR CONCENTRATION ABOVE TIME WEIGHTED TLV; USE NIOSH/MSHA
APPROVED RESPIRATOR.
Ventilation:PROVIDE SUFFICIENT MECHANICAL(GEN) AND/OR LOCAL EXHAUST
VENTILATION TO MAINTAIN EXPOSURE BELOW TLV.
Protective Gloves:CHEMICAL RESISTANT PLASTIC OR RUBBER.
Eye Protection:CHEM WORK GOG OR FULL LNGTH FSHLD.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:DO NOT EAT, DRINK OR SMOKE WHILE USING PRODUCT.
THOROUGHLY WASH HANDS BEFORE EATING OR SMOKING.
Supplemental Safety and Health
MFR TRADE NAME/PART NO: PAINT MIDTONE BASE. EXTING MEDIA:LEAK/SPILL HAS
IGNITED, USE H*2O SPRAY TO DISPERSE VAP & TO PROTECT MEN ATTEMPTING
TO STOP LEAK. MINIMIZE BRTHG GASES, VAP, FUMES/DECOMP PROD. FIRE
FIGHT PROC:SPREAD BURN LIQ W/H*2O USED FOR COOLING. EXPLO
HAZ:POINT. NEVER USE WELD/CUTTING TORCH ON/NEAR (ING 6)

Chemical Properties

HCC:F4
Vapor Pres:2@20F
Vapor Density:4.9
Evaporation Rate & Reference:0.1(BUTYL ACETATE=1)
Solubility in Water:NEGLIG: <0.1%
Appearance and Odor:VISCOUS LIQUID.
Percent Volatiles by Volume:58.9

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG ACIDS OR BASES AND SELECTED AMINES.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL DECOMPOSITION IN PRESENCE OF
AIR MAY YIELD CO AND/OR CO*2.

Disposal

Waste Disposal Methods:DISPOSE OF PRODUCT IN ACCORDANCE WITH APPLICABLE
LOCAL, COUNTY, STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.