BPDPQ - 14-904, DURA CLAD EPOXY MODIFIED ENAMEL (SU

  • MSDS: BPDPQ
  • Manufacturer: DURON INC
  • Product Name: 14-904, DURA CLAD EPOXY MODIFIED ENAMEL (SU
  • National Stock Number: 8010-00N030089
Product Identification

Product ID:14-904, DURA CLAD EPOXY MODIFIED ENAMEL (SU
MSDS Date:07/12/1990
FSC:8010
NIIN:00N030089
MSDS Number: BPDPQ

Responsible Party
DURON INC
10406 TUCKER ST
BELTSVILLE, MD 20706-2297
US

Emergency Phone: 800-228-5636

Info Phone: 301-937-4600

Preparer: THOMAS BRICE

Cage: 75734

Contractor
DURON INC AMERICAN DIV
BELTSVILLE, MD 20705-2201 US

Telephone: 301-937-4600

Cage: 55652

Ingredients

LIGHT HYDROCARBON VAPORS IN SAME NAPHTHA BOILING

RTECS: 9999999ZZ


IF VOMITING OCCURS SPONT, KEEP HEAD BELOW

RTECS: 9999999ZZ


ASSURE CONFORMITY W/APPLIC GOVT REGS. CONTINUE

RTECS: 9999999ZZ


HAS IGNITED, USE H*2O SPRAY TO DISPERSE VAPS &

RTECS: 9999999ZZ


VAPORS, FUMES, OR DECOMPOSITION PRODUCTS.

RTECS: 9999999ZZ


CALCIUM CARBONATE

CAS: 1317-65-3

RTECS: EV9580000

Fraction By Weight: <7.9%

OSHA PEL 15 MG/M3 TDUST;5RESP

ACGIH TLV: 10 MG/M3 TDUST


CLAY (KAOLIN); (KAOLIN)

CAS: 1332-58-7

RTECS: GF1670500

Fraction By Weight: 2.0-5.8%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 2 MG/M3 TDUST; 9293


36.6-43.0.

CAS: 8052-41-3

RTECS: WJ8925000

Fraction By Weight: SEE ING

OSHA PEL 500 PPM

ACGIH TLV: 100 PPM; 9293


SYNTHETIC RESIN; (SYNTHETIC RESIN COMPLEX). %(WT)

Fraction By Weight: SEE ING


3.6-27.1.

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: SEE ING

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


TO LIQ, VAPS, MISTS/FUMES SHOULD BE MINIMIZED.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50: (ORAL,RAT) >5 G/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: EXCESSIVE INHAL OF VAPS CAN
CAUSE NASAL & RESP IRRIT, DIZZ, WEAK, FATIGUE, NAUS, HDCH. HIGH VAP
CONC MAY RSLT IN CNS DEPRESS. LAB ANIMAL STUDIES HAVE SHOWN
PRLNGD/RPTD INHAL EXPOS TO LIGHT HYDR OCARBON VAPS IN SAME NAPHTHA
BOILING RANGE AS PROD CAN PRDCE ADVERSE KIDNEY EFTS IN MALE RATS.
SKIN: (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: PRLNGD/RPTD CONT CAN CAUSE MOD
IRRIT,DEFAT &/OR DERM. EYES:CAN CAUSE SEV IRRIT, REDNESS, TEARING,
BLURRED VISION. INGEST: CAN CAUSE GI IRRIT, NAUS, VOMIT &
DIARR.ASPIR OF MATL INTO LUNGS CAN CAUSE CHEM PNEUM WHICH CAN BE
FATAL. HLTH STUDIES HAVE SHOWN MANY PETRO HYDROCARBONS & SYNTHETIC
LUBRICANTS (SUPP DATA)
Medical Cond Aggravated by Exposure:HIGH VAP CONC (GREATER THAN APPROX
1,000 PPM) ARE IRRITATING TO EYES AND RESPIRATORY TRACT. MAY CAUSE
HEADACHES AND DIZZINESS, ARE ANESTHETIC, AND MAY HAVE OTHER CNS
EFFECTS INCLUDING DEATH.

First Aid

First Aid:INHAL: REMOVE VICTIM TO FRESH AIR & PROVIDE O2 IF BRTHG
DFCLT. IF BRTHG STOPS, BEGIN ARTF RESP & SEEK IMMED MED ATTN. SKIN:
REMOVE CONTAM CLTHG/SHOES. FLUSH SKIN W/H2O FOLLOW BY WASHING
W/SOAP & H2O. IF IRRIT OCCURS, GET MED ATTN. DO NOT REUSE CLTHG
UNTIL CLEANED. EYES: FLUSH W/CLEAR H2O FOR AT LEAST 15 MIN/UNTIL
IRRIT SUBSIDES. IF IRRIT PERSISTS, CALL PHYS.INGEST: DO NOT INDUCE
VOMIT. (ING 8)

Fire Fighting

Flash Point Method:TCC
Flash Point:104F,40C
Lower Limits:0.9%
Upper Limits:6%
Extinguishing Media:USE DRY CHEM, FOAM/CO2. H2O MAY BE INEFT,BUT H2O
SHOULD BE USED TO KEEP FIRE-EXPOS CNTNRS COOL.IF LEAK/SPILL (ING
10)
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. H2O MAY BE UNSUITABLE AS AN EXTING MEDIA, BUT HELPFUL IN KEEPING
ADJACENT CNTNRS COOL. AVOID (SUPP DATA)
Unusual Fire/Explosion Hazard:VAPS ARE HVR/AIR & MAY TRAVEL ALONG
GROUND/ BE MOVED BY VENT & IGNITED BY HEAT, PILOT LIGHTS, OTHER
FLAME & IGNIT SOURCES AT LOCATIONS DISTANT FROM (SUPP DATA)

Accidental Release

Spill Release Procedures:ELIM ALL IGNIT SOURCES (FLARES, FLAMES INCL
PILOT LIGHTS, ELEC SPARKS). RECOVER FREE PROD. ADD SAND,
EARTH/OTHER SUITABLE ABSORB TO SPILL AREA. MIN SKIN CONT. VENT
CONFINED SPACES. KEEP PROD OUT OF SE WERS & WATERCOURSES BY
DIKING/IMPOUNDING. (ING 9)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:THE USE OF RESPIRATORY PROTECTION DEPENDS ON
VAPOR CONCENTRATION ABOVE THE TIME WEIGHTED TLV: USE NIOSH/MSHA
APPROVED RESPIRATOR.
Ventilation:PROVIDE SUFFICIENT MECHANICAL (GENERAL) AND/OR LOCAL
EXHAUST VENTILATION TO MAINTAIN EXPOSURE BELOW TLV.
Protective Gloves:CHEMICAL RESISTANT PLASTIC/RUB GLOVES.
Eye Protection:CHEM WORK GOG & FULL LGTH FACESHLD
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:DO NOT EAT, DRINK OR SMOKE WHILE USING PRODUCT.
THOROUGHLY WASH HANDS BEFORE EATING OR SMOKING.
Supplemental Safety and Health
TRADE NAME/PART #: PAINT WHITE BASE. FIRE FIGHT PROC: SPREADING BURNING
LIQ W/H2O USED FOR COOLING. EXPLO HAZ: HNDLG POINT. NEVER USE
WELDING/CUTTING TORCH ON/NEAR CNTNR (EVEN EMPTY) BECAUSE VAPS MAY
IGNITE. EFTS OF OVEREXP: POSE POTENTIALHUMAN HLTH RISKS WHICH MAY
VARY FROM PERSON TO PERSON. AS PREC, EXPOS (ING 6)

Chemical Properties

HCC:F4
Vapor Pres:2 @ 20F
Vapor Density:4.9
Spec Gravity:1.17
Evaporation Rate & Reference:0.1 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE; <0.1%
Appearance and Odor:VISCOUS LIQUID, HYDROCARBON ODOR.
Percent Volatiles by Volume:67.6

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG ACIDS OR BASES AND SELECTED AMINES.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL DECOMPOSITION IN PRESENCE OF
AIR MAY YIELD CARBON MONOXIDE AND/OR CARBON DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE,
AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.