BPYQJ - PREMIUM STARTING FLUID

  • MSDS: BPYQJ
  • Manufacturer: VALVOLINE INC
  • Product Name: PREMIUM STARTING FLUID
  • National Stock Number: 6850-00N023049
Product Identification

Product ID:PREMIUM STARTING FLUID
MSDS Date:07/19/1989
FSC:6850
NIIN:00N023049
MSDS Number: BPYQJ

Responsible Party
VALVOLINE INC
LEXINGTON, KY 40512
US

Emergency Phone: 800-274-5263

Info Phone: 800-274-5263

Cage: GO029

Contractor
VALVOLINE OIL CO
14000 LEXINGTON, KY 40512 US

Telephone: 606-357-7206 / 800-274-5263

Cage: 72527

Ingredients

CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: 1-10%

OSHA PEL 5000 PPM

ACGIH TLV: 5000PPM/30000STEL;93


HEPTANE

CAS: 142-82-5

RTECS: MI7700000

Fraction By Weight: 55-70%

OSHA PEL 500 PPM/500 STEL

ACGIH TLV: 400 PPM/500STEL;9293


439

CAS: 60-29-7

RTECS: KI5775000

Fraction By Weight: 25-40%

OSHA PEL 400 PPM;500 PPM STEL

ACGIH TLV: 400 PPM;500 PPM STEL

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


HEXANE

CAS: 110-54-3

RTECS: MN9275000

Fraction By Weight: 1-10%

OSHA PEL 500 PPM

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:SKIN:PRLNG/RPTD CONTACT MAY
CAUSE MOD IRRIT, DEFAT, DERM. EYES:MAY CAUSE SEVERE IRRIT, REDNESS,
TEARING, BLURRED VISION. INGEST:MAY CAUSE GI IRRIT, NAUS, VOMIT &
DIARR. ASPIR OF MATL INTO LUNGS MAY CAUSE CHEM PNEUMONIA WHICH MAY
BE FATAL. INHAL:EXCESSIVE INHAL OF VAPS MAY CAUSE NASAL & RESP
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:IRRIT, CNS EFFECTS INCLUDING DIZZ,
WEAKNESS, FATG, NAUS, HDCH & POSSIBLE UNCON & EVEN ASPHYXIATION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN:THORO WASH EXPOSED AREA W/SOAP & H*2O. REMOVE CONTAM
CLTHG & LAUNDER BEFORE REUSE. EYES:FLUSH W/LG AMTS OF H*2O FOR @
LST 15 MIN, LIFTING UPPER & LOWER LIDS OCCAS, GET MD. INGEST:DO NOT
INDUCE VO MIT, KEEP PERS WARM & QUIET & GET MD. ASPIR OF MATL INTO
LUNGS DUE TO VOMIT CAN CAUSE CHEM PNEUM WHICH CAN BE FATAL.
INHAL:REMOVE INDIVIDUAL TO FRESH AIR. IF BRTHG DFCLT, ADMIN O*2. IF
BRTHG (SUPDAT)

Fire Fighting

Flash Point Method:TCC
Flash Point:<-58F,<-50C
Lower Limits:1%
Extinguishing Media:REGULAR FOAM OR CO*2 OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED POSITIVE PRESSURE
DEMAND SCBA & FULL PROTECTIVE EQUIPMENT. .
Unusual Fire/Explosion Hazard:NEVER USE WELDING/CUTTING TORCH ON/NEAR
DRUM (EVEN EMPTY) BECAUSE PROD (EVEN JUST RESIDUE) CAN IGNITE
EXPLOSIVELY.

Accidental Release

Spill Release Procedures:SM SPILL:ALLOW TO EVAPORATE. VENT AREA. ELIM
ALL SOURCES OF IGNIT SUCH AS FLARES, FLAMES (INCL PILOT LIGHTS) &
ELEC SPKS. LG SPILL:ELIM ALL IGNIT SOURCES (FLARES, FLAMES, INCL
PILOT LIGHTS, ELEC SPKS) . ALLOW TO EVAP. PERSONS NOT WEARING PROT
(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:CNTNRS OF MATL MAY BE HAZ WHEN EMPTIED. SINCE EMPTIED
CNTNRS RETAIN PROD RESIDUES (VAP, LIQ &/OR SOLID), ALL HAZ PRECS
GIVEN IN THIS MSDS MUST BE OBSERVED.

Exposure Controls

Respiratory Protection:IF WORKPLACE EXPOS LIMIT OF PROD/ANY COMPONENT
IS EXCEEDED, NIOSH/MSHA APPRVD AIR SUPPLIED RESP IS ADVISED IN
ABSENCE OF PROPER ENVIRON CONTROL. OSHA REGS ALSO PERMIT OTHER
NIOSH/MSHA APPRVD RESPS (NE G PRESS TYPE) UNDER SPECIFIED (SUPDAT)
Ventilation:PROVIDE SUFFICIENT MECH (GEN &/OR LOC EXHST) VENT TO
MAINTAIN EXPOSURE BELOW TLV.
Protective Gloves:NOT REQUIRED UNDER NORMAL CNDTNS OF USE.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NOT REQUIRED UNDER NORMAL CONDITIONS OF USE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID PROC:HAS STOPPED GIVE ARTF RESP. KEEP PERS WARM, QUIET & GET
MD. SPILL PROC:EQUIP SHOULD BE EXCLUDED FROM AREA UNTIL LEAK HAS
BEEN REPAIRED. RESP PROT:CONDITIONS. ENGINEERING OR ADMINISTRATI VE
CONTROLS SHOULD BE IMPLEMENTED TO REDUCE EXPOSURE.

Chemical Properties

HCC:G2
Boiling Pt:B.P. Text:SEE ING 3
Vapor Pres:SEE ING 3
Vapor Density:HVR/AIR
Spec Gravity:< H*2O
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:COMP GAS
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY FORM TOXIC MATERIALS; CO*2 & CO,
VARIOUS HYDROCARBONS, ETC.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULTATIONS . SM SPILL:ALLOW MATL TO EVAPORATE. LG SPILL:VENTILATE
AREA OF SPILL. ALLOW MATL TO EVAPORATE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.