BQCDG - WALL KOTE ALKYD SEMI GLOSS PAINT, ACCENT BA

  • MSDS: BQCDG
  • Manufacturer: DURON INC
  • Product Name: WALL KOTE ALKYD SEMI GLOSS PAINT, ACCENT BA
  • National Stock Number: 8010-00N035101
Product Identification

Product ID:WALL KOTE ALKYD SEMI GLOSS PAINT, ACCENT BA
MSDS Date:12/26/1991
FSC:8010
NIIN:00N035101
MSDS Number: BQCDG

Responsible Party
DURON INC
10406 TUCKER ST
BELTSVILLE, MD 20706-2297
US

Emergency Phone: 800-228-5635

Info Phone: 301-937-4600

Cage: 75734

Contractor
DURON INC AMERICAN DIV
BELTSVILLE, MD 20705-2201 US

Telephone: 301-937-4600

Cage: 55652

Ingredients

SPONT, KEEP HEAD BELOW HIPS TO PREVENT

RTECS: 9999999ZZ


ASSURE CONFORMITY W/APPLIC GOVT REGS. CONTINUE

RTECS: 9999999ZZ


15 MG/M3 TDUST; 5 MG/M3 RDUST

CAS: 1317-65-3

RTECS: EV9580000

Fraction By Weight: 3.7-8%

OSHA PEL SEE INGREDIENT NAME

ACGIH TLV: 10 MG/M3 TDUST


10 MG/M3 TDUST; 5 MG/M3 RDUST

CAS: 1332-58-7

RTECS: GF1670500

Fraction By Weight: 9.1-9.3%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 2 MG/M3 TDUST; 9293


STODDARD SOLVENT

CAS: 8052-41-3

RTECS: WJ8925000

Fraction By Weight: 23.8-29%

OSHA PEL 500 PPM

ACGIH TLV: 100 PPM; 9293


SYNTHETIC RESIN; (SYNTHETIC RESIN COMPLEX). %(WT)

Fraction By Weight: SEE ING


TITANIUM OXIDE; (TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 3.4-27%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


4.15 POUNDS/GALLON

RTECS: 9999999VO


PRLNGD/RPTD CONT CAN CAUSE MOD IRRIT,

RTECS: 9999999ZZ


CAN CAUSE GI IRRIT,

RTECS: 9999999ZZ


CHEM PNEUMONITIS WHICH CAN BE FATAL. MISC TOX

RTECS: 9999999ZZ


SYNTHETIC LUBRICANTS POSE POTNTL HUMAN HLTH RISKS

RTECS: 9999999ZZ


LIQS/VAPS/MISTS/FUMES SHOULD BE MINIMIZED. PROD

RTECS: 9999999ZZ


HAZ BY INHAL & PROBABLY CARCIN FOR HUMANS. CS CAN

RTECS: 9999999ZZ


PIGMENT DUST WOULD NOT NORMALLY BE ENCOUNTERED WHEN

RTECS: 9999999ZZ


PIGMENT. PROPER NIOSH/MSHA APPRVD RESP PROT SHOULD

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50:(ORAL RAT) >5 G/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHAL:EXCESSIVE INHAL OF VAPS CAN
CAUSE NASAL & RESP IRRIT, DIZZ, WEAK, FATIGUE, NAUS & HDCH. HIGH
VAP CONC MAY RESLT IN CNS DEPRESS. LAB ANIMAL STUDIES HAVE SHOWN
THAT PRLNGD/RPTD EXPOS TO LIGHT HYDR OCARBON VAPS IN SAME NAPHTHA
BOILING RANGE AS PROD CAN PRDCE ADVERSE KIDNEY EFTS IN MALE RATS.
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:CRYSTALLINE SILICA: GROUP 2A (IARC)
Effects of Overexposure:HLTH HAZ:HOWEVER, THESE EFTS WERE NOT OBSERVED
IN SIMILAR STUDIES W/FEMALE RATS & MALE/FEMALE MICE & IN LIMITED
STUDIES W/OTHER ANIMALS. IN A NUMBER OF HUMAN STUDIES, THERE WAS NO
CLININAL EVID OF SUC H EFTS AT NORM OCCUP LEVELS. IT IS HIGHLY
UNLIKELY THAT KIDNEY EFTS OBSERVED IN MALE RATS HAVE SIGNIFICANT
(SUPP DATA)
Medical Cond Aggravated by Exposure:HIGH VAPOR CONC (>1000 PPM) ARE
IRRITATING TO EYES & RESPIRATORY TRACT. MAY CAUSE HDCH, DIZZ, ARE
ANESTH, & MAY HAVE OTHER CNS EFFECTS INCLUDING DEATH.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR & PROVIDE OXYGEN IF BRTHG IS DFCLT.
IF BRTHG STOPS, BEGIN ARTF RESP & SEEK MD IMMED. SKIN:REMOVE
CONTAMD CLTHG/SHOES. FLUSH W/WATER. FOLLOW BY WASHING W/SOAP &
WATER. IF IRRI T OCCURS, GET MD. DO NOT REUSE CLTHG UNTIL CLEANED.
EYES:FLUSH W/CLEAN WATER FOR AT LEAST 15 MINS OR UNTIL IRRIT
SUBSIDES. IF IRRIT PERSISTS, CALL MD. INGEST:DO NOT INDUCE VOM. IF
VOM OCCURS (ING 15)

Fire Fighting

Flash Point Method:TCC
Flash Point:104F,40C
Lower Limits:0.9%
Upper Limits:6%
Extinguishing Media:USE DRY CHEMICAL, FOAM OR CO*2. WATER MAY BE INEFT,
BUT WATER SHOULD BE USED TO KEEP FIRE EXPOSED CONTRS COOL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. IF LEAK/SPILL HAS IGNITED, USE WATER SPRAY TO DISPERSE VAPS &
PROT MEN ATTEMPTING TO STOP LEAK.(SUPP DATA)
Unusual Fire/Explosion Hazard:VAPS ARE HVR THAN AIR & MAY TRAVEL ALONG
GROUND OR BE MOVED BY VENT & IGNITED BY HEAT, PILOT LIGHTS, OTHER
FLAME & IGNIT SOURCES AT LOCATIONS DISTANT (SUP DAT)

Accidental Release

Spill Release Procedures:ELIM IGNIT SOURCES (FLARES/FLAMES INCL PILOT
LIGHTS/ELEC SPRKS). RECOVER FREE PROD. ADD SAND/EARTH/OTHER
SUITABLE ABSORB TO SPILL AREA. MINIMIZE SKIN CONT. VENT CONFINED
SPACES. KEEP PROD OUT OF SEWER S/WATERCOURSES BY DIKING/IMPOUNDING
(ING 16)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:THE USE OF RESPIRATORY PROTECTION DEPENDS ON
VAPOR CONCENTRATION ABOVE THE TIME WEIGHTED TLV: USE NIOSH/MSHA
APPROVED RESPIRATOR.
Ventilation:PROVIDE SUFFICIENT MECHANICAL (GENERAL) &/OR LOCAL EXHAUST
VENTILATION TO MAINTAIN EXPOSURE BELOW TLV.
Protective Gloves:CHEM RESISTANT PLASTIC OR RUBBER GLOVES.
Eye Protection:CHEM WORK GOGGS/FULL LENGTH FSHLD
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:DO NOT EAT, DRINK OR SMOKE WHILE USING THIS
PRODCUT. THOROUGHLY WASH HANDS BEFORE EATING OR SMOKING.
Supplemental Safety and Health
FIRE FIGHT PROC:MINIMIZE BRTHG GASES, VAPS, FUMES OR DECOMP PRODS.
AVOID SPREADING BURNING LIQ W/WATER USED FOR COOLING. EXPLO
HAZ:FROM HNDLNG POINT. NEVER USE WELDING/CUTTING TORCH ON/NEAR
CONTR (EVE N EMPTY) BECAUSE VAPS MAY IGNITE. EFTS OF
OVEREXP:IMPLICATIONS FOR HUMANS AT/BELOW RECOM VAP LIMITS IN
WORKPLACE.(ING 7)

Chemical Properties

HCC:F4
Vapor Pres:2 @ 20F
Vapor Density:4.9
Spec Gravity:1.03
Evaporation Rate & Reference:0.1 (BUTYL ACETATE=1)
Solubility in Water:<0.1%
Appearance and Odor:VISCOUS LIQUID.
Percent Volatiles by Volume:62.3

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG ACIDS OR BASES & SELECTED AMINES.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL DECOMPOSITION IN THE PRESENCE
OF AIR MAY YIELD CARBON MONOXIDE &/OR CARBON DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE OF PRODUCT IN ACCORDANCE W/APPLICABLE
LOCAL, COUNTY, STATE & FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.