BQDBR - FM (R) 410 CORE SPLICE ADHESIVE FOAM
- MSDS: BQDBR
- Manufacturer: AMERICAN CYANAMID
- Product Name: FM (R) 410 CORE SPLICE ADHESIVE FOAM
- National Stock Number: 8040-01-296-1793
Product Identification
Product ID:FM (R) 410 CORE SPLICE ADHESIVE FOAM
MSDS Date:01/12/1989
FSC:8040
NIIN:01-296-1793
MSDS Number: BQDBR
Responsible Party
WAYNE, NJ 07470
US
Emergency Phone: 201-835-3100
Info Phone: 201-835-3100
Preparer: DR MARVIN A FRIEDMAN
Cage: 07542
Contractor
Telephone: 201-835-3100
Cage: 07542
Ingredients
GLASS
Fraction By Weight: 4.4%
ACGIH TLV: 10 MG/M3 CEILING
SILICA, AMORPHOUS
CAS: 112945-52-5
RTECS: VV7310000
Fraction By Weight: 28.5%
OSHA PEL 6 MG/M3
ACGIH TLV: 10 MG/M3
EPOXY RESIN
Fraction By Weight: 60-100%
Hazards
LD50 LC50 Mixture:ORAL LD50 RAT>7.5G/KG.LC50 RAT>250MG/M3.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Health Hazards Acute and Chronic:BASED ON PHYSICAL FORM, OVEREXPOSURE
BY INGESTION OR INHALATION WILL NOT OCCUR. ALLERGIC SKIN REACTION
OR PRIMARY SKIN IRRITATION MAY BE PRODUCED BY PROLONGED OR REPEATED
DERMAL CONTACT WITH EPOXY RES INS. OVEREXPOSURE TO VAPOR DURING
HEAT CURING MAY CAUSE IRRITATION OR INJURY TO RESPIRATORY TRACT &
EYE IRRITATION. *
Effects of Overexposure:* OVEREXPOSURE TO SYNTHETIC AMORPHOUS SILICA
DUST BY INHAL, SKIN, ORAL, DERMAL ROUTE NOT EXPECTED TO CAUSE
ADVERSE EFFECTS. PRODUCT CONTAINS NONE OF CRYSTALLINE VARIETIES OF
SILICA KNOWN TO CAUSE LUNG DISEASE. OVEREXPOSURE TO GLASS FIBERS
CAUSES SKIN & EYE IRRIT. INHAL OF GLASS FIBERS MAY CAUSE RESP
CONGESTION/IRRIT.
First Aid
First Aid:IN CASE OF SKIN CONTACT, IMMEDIATLEY WASH AFFECTED AREA WITH
SOAP AND PLENTY OF WATER. REMOVE CONTAMINATED CLOTHING AND SHOES.
OBTAIN MEDICAL ATTENTION. DESTROY OR THOROUGHLY CLEAN SHOES BEFORE
REUSE. DO NOT REUSE CONTAMINATED CLOTHING WITHOUT LAUNDERING. IN
CASE OF EYE CONTACT, IMMEDIATELY IRRIGATE WITH PLENTY OF WATER FOR
15 MINUTES.
Fire Fighting
Extinguishing Media:USE WATER, CARBON DIOXIDE OR DRY CHEMICAL TO
EXTINGUISH FIRES.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS,
POSITIVE PRESSURE BREATHING APPARATUS AND FULL FIREFIGHTING
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:MATERIAL MUST BE PREHEATED BEFORE
IGNITION CAN OCCUR.
Accidental Release
Spill Release Procedures:EXPOSURE LEVEL UNKNOWN; WEAR NIOSH POSITIVE
PRESSURE, SELF-CONTAINED RESPIRATOR; KNOWN, WEAR NIOSH APPRVD
RESPIRATOR APPROP FOR LEVEL OF EXPOSURE. SWEEP UP SPILL & PLACE IN
WASTE DISPOSAL CNTNR. FLUSH AREA W/WATER.
Handling
Handling and Storage Precautions:CUTTING, GRINDING, OR SANDING OF PARTS
FABRICATED AFTER CURING OF THIS MATERIAL MAY CREATE RESPIRABLE DUST
PARTICLES.
Other Precautions:AVOID SKIN CONTACT.
Exposure Controls
Respiratory Protection:BELOW PEL, RESPIRATORY PROTECTION NOT REQ'D.
ABOVE PEL, USE NIOSH RESPIRATOR FOR MAT'L & LEVEL OF EXPOSURE.
RESPIRATORY PROTECTION FOR DUST MAY BE REQ'D
(CUTTING,GRINDING,SANDING). SEE "GUIDE TO INDUS TRIAL RESPIRATORY
PROTECTION" (NIOSH).
Ventilation:WHEN NOT USED IN A CLOSED SYSTEM, PROVIDE GOOD ENCLOSURE &
LOCAL EXHAUST VENT WHEN SPRAYING OR CURING AT ELEVATED TEMPS.
Protective Gloves:BARRIER CREAM IN CONJUNCTION W/GLOVES
Eye Protection:IF CONTACT, CHEM SPLASH GOGGLES,FACESHLD
Other Protective Equipment:EYE WASH,SAFETY SHOWER IF EXPOSURE
POTENTIAL.PROTECT CLOTH(APRO,WRK PANTS,LONG SLEEVE WRK
SHIRT,DISPOSABLE COVERALLS).
Work Hygienic Practices:DONT CARRY/STORE FOOD,BEVERAGES,TOBACCO WHERE
MAT'L IN USE.BEFORE EATING,DRINKING,SMOKING,WASH FACE/HANDS W/SOAP
& WATER
Supplemental Safety and Health
Chemical Properties
Spec Gravity:1.08-1.10
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BLUE FILM, NO ODOR
Percent Volatiles by Volume:NEGLIG
Stability
Stability Indicator/Materials to Avoid:YES
NO SPECIFIC INCOMPATIBILITY
Stability Condition to Avoid:NONE KNOWN
Hazardous Decomposition Products:THERMAL DECOMPOSITION OR COMBUSTION
MAY PRODUCE CARBON MONOXIDE AND/OR CARBON DIOXIDE.
Conditions to Avoid Polymerization:POLYMERIZATION MAY OCCUR SLOWLY AT
ROOM TEMPERATURE. STORE AT OR BELOW 0 F.
Disposal
Waste Disposal Methods:DISPOSAL MUST BE MADE IN ACCORDANCE WITH
APPLICABLE GOVERNMENTAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.