BRDGP - 2319 ALUMINUM

  • MSDS: BRDGP
  • Manufacturer: THERMACOTE WELCO
  • Product Name: 2319 ALUMINUM
  • National Stock Number: 3439-00F028021
Product Identification

Product ID:2319 ALUMINUM
MSDS Date:02/09/1990
FSC:3439
NIIN:00F028021
MSDS Number: BRDGP

Responsible Party
THERMACOTE WELCO
HWY 161 S YORK RD
KINGS MOUNTAIN, NC 28086
US

Emergency Phone: 704-739-6421

Info Phone: 704-739-6421

Cage: 0AES5

Contractor
THERMACOTE WELCO CO
KINGS MOUNTAIN, NC 28086 US

Cage: 0AES5

Ingredients

MAGNESIUM OXIDE, MAGNESIA

CAS: 1309-48-4

RTECS: OM3850000

OSHA PEL 15 MG/M3 PARTICULATE

ACGIH TLV: 10 MG/M3;TDUST; 9293


MANGANESE, MN COMPOUNDS

CAS: 7439-96-5

RTECS: OO9275000

OSHA PEL (C) 5 MG/M3 DUST

ACGIH TLV: 5 MG/M3 DUST 9293


SILICON

CAS: 7440-21-3

RTECS: VW0400000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


SILVER

CAS: 7440-22-4

RTECS: VW3500000

OSHA PEL 0.01 MG/CUM

ACGIH TLV: 0.1 MG/CUM

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


TIN (AS SN)

CAS: 7440-31-5

RTECS: XP7320000

OSHA PEL 2.0 MG/CUM

ACGIH TLV: 2.0 MG/CUM


ZINC OXIDE

CAS: 1314-13-2

RTECS: ZH4810000

OSHA PEL 15MG/M3 TDUST/5 FUME

ACGIH TLV: 10MG/M3 TDUST; 9293


ALUMINUM (POWDER)

CAS: 7429-90-5

RTECS: BD0330000

OSHA PEL 15 MG/CUM

ACGIH TLV: 10 MG/CUM (DUST)


COBALT

CAS: 7440-48-4

RTECS: GF8750000

OSHA PEL 0.1 MG/M3;AS CO

ACGIH TLV: 0.05 MG/M3;DUST 9293


COPPER (DUST & MIST), BRONZE POWDER

CAS: 7440-50-8

RTECS: GL5325000

OSHA PEL 0.1 MG(CU)/M3 (FUME)

ACGIH TLV: 0.2 MG/M3 (FUME)

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


RED IRON OXIDE/IRON (III) OXIDE/FERRIC OXIDE/YELLOW FERRIC

CAS: 1309-37-1

RTECS: NO7400000

OSHA PEL 10 MG/M3 (FE)

ACGIH TLV: 5 MG/M3(FE),B2; 9293

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: NOT LIKELY UNLESS MATERIAL
IS MACHINED/WELDED/REMELTED. EXPOSURE TO ZINC OXIDE FUME CAN RESULT
IN ZINC CHILLS (METAL FUME FEVER). TEMPORARY SYMPTOMS
(FEVER/CHILLS/NAUSEA/VOMITING/MUSCULAR PAIN). RECOVERY USUALLY
COMPLETE IN 24-48 HRS. EYE: IRRITATION WHEN WELDING/PLASMA CUTTING.
SKIN: BURN FROM HOT METAL.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: UPPER RESPIRATORY TRACT IRRITATION
FROM COPPER FUME. SKIN: IRRITATION.

First Aid

First Aid:SKIN: REMOVE PARTICLES BY THOROUGHLY WASHING W/SOAP & WATER.
EYES: FLUSH W/WATER FOR AT LEAST 15 INS. INHALATION: REMOVE FROM
EXPOSURE. OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Extinguishing Media:DRY POWDER OR SAND
Fire Fighting Procedures:DON'T USE WATER OR HALOGEN ON DUST FIRES.
Unusual Fire/Explosion Hazard:DAMP ALUMINUM DUST MAY SPONTANEOUSLY HEAT
W/LIBERATION OF HYDROGEN TO FORM EXPLOSIVE AIR MIXTURES. FLAMMABLE
SOLID. CONTACT W/AMMONIUM NITRATE CAUSES EXPLOSION.

Handling

Handling and Storage Precautions:MOISTURE MUST BE DRIVEN OFF PRIOR TO
REMELTING. DON'T TOUCH CAST ALUMINUM METAL/HEATED ALUMINUM PRODUCT
W/OUT KNOWING METAL TEMPERATURE.
Other Precautions:ALUMINUM EXPERIENCES NO COLOR CHANGE DURING HEATING.
SOME ALUMINUM SCRAP MAY BE CONTAMINATED W/OIL AT LEVELS >1%.
MELTING OF ALUMINUM SCRAP MAY GENERATE OIL VAPORS WHICH ARE
IRRITATING TO THE EYES & U PPER RESPIRATORY TRACT.

Exposure Controls

Respiratory Protection:AS REQUIRED.
Protective Gloves:AS REQUIRED.
Eye Protection:AS REQUIRED.
Other Protective Equipment:AS REQUIRED.
MELTING/CASTING/MACHINING/FORGING/OR OTHERWISE PROCESSING MAY
REQUIRED PROTECTIVE EQUIPMENT.
Supplemental Safety and Health
HARD ALLOY INGOTS IN THE 2000 & 7000 SERIES MUST BE STRESS-RELIEVED TO
PREVENT EXPLOSION (OR VIOLENT CRACKING) WHEN SAWED. VAPOR DEGREASER
MUST BE PROPERLY MAINTAINED TO LIMIT THE ACCUMULATION OF ALUM INUM
FINES WHICH COULD RESULT IN A POTENTIAL DEGREASER FIRE OR
EXPLOSION.

Chemical Properties

Melt/Freeze Pt:M.P/F.P Text:950-1215F
Spec Gravity:2.5-2.9
Solubility in Water:INSOLUBLE
Appearance and Odor:METALLIC APPEARANCE, NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
BROMATES, IODATES, OR AMMONIUM NITRATE. STRONG OXIDIZERS SUCH AS
AMMONIUM NITRATE
Stability Condition to Avoid:HEAT, MOISTURE
Hazardous Decomposition Products:HYDROGEN, CO, CO2, OZONE, NITROGEN
OXIDES, INFRA-RED RADIATION, ULTRA-VIOLET RADIATION, & METAL FUMES

Disposal

Waste Disposal Methods:USED OR UNUSED PRODUCT SHOULD BE TESTED TO
DETERMINE HAZARD STATUS & DISPOSAL REQUIREMENTS UNDER FEDERAL,
STATE, OR LOCAL REGULATIONS. FLAMMABLE SOLID. UN1396.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.