BSKHR - EAS OFF, 81868
- MSDS: BSKHR
- Manufacturer: CURTIS INDUSTRIES
- Product Name: EAS OFF, 81868
- National Stock Number: 9150-00N047120
Product Identification
Product ID:EAS OFF, 81868
MSDS Date:04/07/1986
FSC:9150
NIIN:00N047120
MSDS Number: BSKHR
Responsible Party
EASTLAKE, OH 44094
US
Emergency Phone: 216-951-2400 EXT 5678
Info Phone: 216-951-2400 EXT 282
Cage: 91636
Contractor
Telephone: 216951-2400 EXT. 282
Cage: 91636
Ingredients
METHANE, DICHLORO-; (METHYLENE CHLORIDE) (SARA III)
CAS: 75-09-2
RTECS: PA8050000
Fraction By Weight: 20%
OSHA PEL 500 PPM; 1000,C
ACGIH TLV: 50 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
PROPANE
CAS: 74-98-6
RTECS: TX2275000
Fraction By Weight: 13%
OSHA PEL 1000 PPM
ACGIH TLV: ASPHYXIANT
MINERAL SPIRITS
CAS: 64742-88-7
Fraction By Weight: 12%
OSHA PEL N/K
ACGIH TLV: N/K
KEROSENE
CAS: 8008-20-6
RTECS: OA5500000
Fraction By Weight: 12%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:MAY CAUSE DIZZ/NORCOSIS IN HIGH VAP
CONC. WILL CAUSE DEFATTING OF SKIN. EFTS ARE REVERSIBLE. LONG TERM
EXPOS (YRS) VAP MAY CAUSE LUNG, LIVER OR KIDNEY DAM.
INHAL:DIFFICULATY IN BRTHG. SKIN: REDNESS. I NGEST:VOMITING.
CHLOROCARBON MATLS HAVEPRODUCED SENSIT OF MYOCARDIUM TO EPINEPHRINE
IN LAB ANIMALS & (EFTS OF OVEREXPOS
Explanation of Carcinogenicity:METHYLEN CHLORIDE:IARC MONOGRAPHS
SUPPLEMENT, VOL 7, PG 194, 1987:GR 2B. NTP 6TH ANNUAL REPORT ON
CARCINOGENS, (SUPDAT)
Effects of Overexposure:HLTH HAZ:COULD HAVE A SIMILAR EFT IN HUMANS.
ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT
FOR LIFE- SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED
TO CHLOROCARBONS .
Medical Cond Aggravated by Exposure:HEART DISEASE.
First Aid
First Aid:INHAL:GIVE OXYGEN. INGEST:DO NOT INDUCE VOMITING. GASTRIC
LAVAGE. EYES:WASH THOROUGHLY WITH WATER FOR AT LEAST 15 MINUTES.
SKIN:WASH WITH WATER.
Fire Fighting
Flash Point Method:TCC
Flash Point:-40F,-40C
Lower Limits:1.8%
Upper Limits:12.0%
Extinguishing Media:USE WATER FOG, DRY CHEMICAL OR CARBON DIOXIDE.
Fire Fighting Procedures:NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA &
FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:HEATED CANS MAY BURST. THERMAL
DECOMPOSITION PRODUCTS MAY INCLUDE HCL & PHOSGENE .
Accidental Release
Spill Release Procedures:USE ABSORBENT SWEEPING COMPOUND TO SOAK UP
MATERIAL. PUT INTO CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS, OR OPEN
FLAME. STORE AT TEMPERATURES BELOW 120F.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE THE FORMATION OF HCL AND/OR PHOSGENE .
Exposure Controls
Respiratory Protection:MIOSH/MSHA APPRVD SELF CONTAINED BREATHING
APPARATUS IF ABOVE TLV LIMIT EXCEEDING.
Ventilation:LOCAL:YES. MECH:NONE.
Protective Gloves:NONE REQUIRED IF SPRAYING.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:LONG SLEEVE AND LONG PANTS.
Work Hygienic Practices:WASH HANDS AFTER USE.
Supplemental Safety and Health
EXPLAN OF CARCIN:1991:ANTICIPATED TO BE CARCINOGEN HUMAN:LIVER.
Chemical Properties
HCC:V3
Boiling Pt:B.P. Text:>-40F,>-40C
Decomp Temp:Decomp Text:N.K
Vapor Pres:40 PSIG
Vapor Density:4 HVR/AIR
Spec Gravity:0.8 (H20=1)
Evaporation Rate & Reference:0.2 (BUTYL ACETATE=1)
Solubility in Water:NONE
Appearance and Odor:GRAY-SOLVENT ODOR
Stability
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:HIGH TEMPERATURES.
Hazardous Decomposition Products:IN A FIRE, FORMS CARBON DIOXIDE AND
WATER. HCL, PHOSGENE .
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, LOCAL AND
STATE REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.