BTTDM - GENETRON (FC) 134A

Product Identification

Product ID:GENETRON (FC) 134A
MSDS Date:12/01/1994
FSC:6830
NIIN:01-370-6207
MSDS Number: BTTDM

Responsible Party
ALLIED-SIGNAL INC, ENGINEERED MATERIAL SECTOR
101 COLUMBIA RD
MORRISTOWN, NJ 07962
US

Emergency Phone: 201-455-2000

Info Phone: 201-455-4157

Cage: 0B7T5

Contractor
REFRIGERANT RECLAIM SERVICES INC / DBA FULL CYCLE
HURST, TX 76053 US

Telephone: 817-282-0022

Cage: 0YD89

Ingredients

1,1,1,2-TETRAFLUOROETHANE

CAS: 811-97-2

Fraction By Weight: 100%

Hazards

LD50 LC50 Mixture:LC50 INHAL RAT IS 500,000PPM/4HRS
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN-IRRITATION WOULD RESULT FROM A
DEFATTING ACTION ON SKIN. EYES-LIQUID CONTACT CAN CAUSE IRRITATION,
WHICH MAY BE SEVERE. MIST MAY IRRITATE. INHALATION-GENETRON 134A IS
A LOW ORDER ACUTE TOXICITY I N ANIMALS. WHEN OXYGEN LEVELS IN AIR
AREREDUCED TO 12-14% BY DISPLACEMENT SYMPTOMS OF ASPHYXIATION.,
LOSS OF COORDINATION, INCREASED PULSE RATE AND DEEPER RESPIRATION
WILL OCCUR. INGESTION-ALTHOUGH IN GESTION IS UNLIKELY, DISCOMFORT
IN THE GASTROINTESTINAL TRACT WOULD RESULT FROMRAPID EVAPORATION OF
THE MATERIAL AND CONSEQUENT ELEVATION OF GAS.
Explanation of Carcinogenicity:NONE.
Effects of Overexposure:INHALATION-AT HIGH LEVELS, CARDIAC ARRYTHMIA
MAY OCCUR. INGESTION-NECROSIS FROM FREEZING OF TISSUE COULD OCCUR.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MFG.

First Aid

First Aid:SKIN-PROMPTLY FLUSH SKIN WITH WATER UNTIL ALL CHEMICAL IS
REMOVED. IF FROSTBITE, BATHE WITH LUKEWARM WATER. COVER WITH CLEAN,
SOFT CLOTH OR SIMILIAR COVERING. CALL A PHYSICIAN. EYE-FLUSH EYES
WITH LAR GE AMOUNTS OF WATER FOR 15 MIN, LIFTINGEYELIDS
OCCASIONALLY TO FACILITATE IRRIGATION. GET MEDICAL ATTENTION.
INHALE-REMOVE TO FRESH AIR. IF BREATHING SYOPS, GIVE ARTIFICIAL
RESPIRATION. USE OXYGEN AS REQUIRED, PROVIDED A QUALIFIED OPERATOR
IS AVAILABLE. CALL PHYSICIAN. DON'T GIVE EPINEPHRINE(ADRENALINE).
INGESTION-INGESTION IS UNLIKELY. DO NOT INDUCE VOMITING, UNLESS
INSTRUCTED TO DO SO BY A PHYSI CIAN.

Fire Fighting

Flash Point:NONE
Autoignition Temp:Autoignition Temp Text:>750C
Extinguishing Media:USE ANY STANDARD AGENT---CHOOSE THE ONE MOST
APPROPRIATE FOR TYPE OF SURROUNDING FIRE (MATERIAL ITSELF IS NOT
FLAMMABLE)
Fire Fighting Procedures:WEAR NIOSH-APPROVED SCBA FOR PROTECTION
AGAINST POSSBILE TOXIC DECOMPOSITION PRODUCTS.PROPER EYE/SKIN
PROTECTION. USE H2O SPRAY TO COOL CNTRS & SUPRRESS VAPORS.
Unusual Fire/Explosion Hazard:CONTACT W/CERTAIN REACTIVE METALS MAY
RESULT IN EXPLOSION OR EXOTHERMIC REACTIONS UNDER SPECIFIC
CONDITIONS(EG VERY HI TEMP &/OR APPROPRIATE PRESSURE).

Accidental Release

Spill Release Procedures:EVACUATE UNPROTECTED PERSONNEL. PROTECTED
PERSONNEL SHOULD REMOVE FLAMES & SHUT OFF LEAK IF W/O RISK. PROVIDE
VENTILATION. UNPROTECTED PERSONNEL SHOULD NOT RETURN UNTIL AIR HAS
BEEN TESTED & DETERMINE D SAFE, PARTULARLY IN LOW-LYING AREAS.
Neutralizing Agent:NOT APPLICABLE.

Handling

Handling and Storage Precautions:STORE IN COOL, WELL-VENTILATED AREA OF
LOW FIRE RISK. PROTECT CYLINDER & FITTINGS FROM PHYSICAL DAMAGE.
STORAGE IN SUBSURFACE LOCATIONS SHOULD BE AVOIDED.
Other Precautions:CLOSE VALVE TIGHTLY AFT USE & WHEN EMPTY. AVOID
BREATH VAPORS & LIQUID CONTACT W/EYES/SKIN/CLOTH. DON'T PUNCTURE OR
DROP CYLINDER OR EXPOSE THEM TO OPEN FLAME OR EXCESSIVE HEAT. USE
AUTHORIZED CYLINDE R ONLY. FOLLOW STD SAFETY PRECAUT FOR HANDL/USE
CYL.

Exposure Controls

Respiratory Protection:NONE GENERALLY REQUIRED FOR ADEQUATELY
VENTILATED WORK SITUATIONS.FOR ACCIDENTAL OR NON-VENTILATED
SITUATIONS FROM ESTIMATED TLV TO 5000PPM USE NIOSH SCBA OR SUPPLIED
AIR RESP.FOR ESCAPE USE FORMER OR NIOSH GAS MASK W/ORG VAPOR
CANISTER.
Ventilation:PROVIDE LOCAL EXHAUST @ FILLING ZONES & AREAS WHERE LEAKAGE
IS PROBABLE. MECHANICAL (GENERAL) VENTILATION MAY BE ADEQUATE FOR
OTHERS.
Protective Gloves:IMPERVIOUS WITH PVA OUTER LAYER; NEOPRENE.
Eye Protection:SAFETY GLASSES, CHEMICAL SAFETY GOGGLES.
Other Protective Equipment:IMPERVIOUS SHOES/CLOTH WHERE LEAKAGE IS
PROBABLE & SHOULD BE THERMALLY INSULATED TO PREVENT FREEZING. NO
CONTACT LENSES.
Work Hygienic Practices:DON'T WEAR CNTCT LENSES.EYEWASH STATIONS,SAFETY
SHOWERS.OBSERVE ALL LABELED PRECAUTIONS. FORMAL ENTRY PROCEDURES
FOR TANK
Supplemental Safety and Health
TESTS SHOW THAT AN AIR-RICH MIXTURE W/ GENETRON 134A @ SLIGHTLY OVER
ATM PRESSURE IS COMBUSTIBLE WHEN EXPOSED TO AN EXPLODING COPPER
WIRE. NONEXPLOSIVE CONDITIONS MAY YIELD TOXIC &/OR CORROSIVE DECOMP
OSITION PRODUCTS.FIRST AID INGEST:UNLIKELY DUE TO PHYSICAL
PROPERTIES.INDUCE VOMITING ONLY UNDER MEDICAL SUPERVISION.

Chemical Properties

HCC:G3
Boiling Pt:=-26.2C, -15.2F
Melt/Freeze Pt:=-101.C, -149.8F
Vapor Pres:85.8 @70F
Vapor Density:3.5(AIR=1)
Spec Gravity:1.222 @21.1C
Evaporation Rate & Reference:>1 COMPARED TOCCL4
Solubility in Water:.15WT%
Appearance and Odor:CLEAR, COLORLESS LIQUID AND VAPOR FAINT ETHEREAL
ODOR
Percent Volatiles by Volume:@20C=100

Stability

Stability Indicator/Materials to Avoid:YES
FRESHLY ABRADED AL SURFACES MAY CAUSE STRONG EXOTHERMIC REACTION.
CHEMICALLY ACTIVE METALS (NA,K,CA,POWDERED AL,MG,ZN).
Stability Condition to Avoid:DO NOT MIX WITH OXYGEN OR AIR ABOVE
ATMOSPHERIC PRESSURE. ANY SOURCE OF HIGH TEMPERATURE, SUCH AS
LIGHTED CIGARETTES, FLAMES, HOT SPOTS, WELDING MAY YIELD TOXIC
AND/OR CORROSIVE DECO
Hazardous Decomposition Products:HALOGENS, HALOGEN ACIDS, POSSIBLY
CARBONYL HALIDES (PHOSGENE). THESE ARE TOXIC & CORROSIVE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL,STATE AND
LOCAL REGULATIONS.

Toxicology

Toxicological Information:LC50 (RAT) 4 HR>500,000 PPM. CARDIAC
SENSITIZATION THRESHOLD: 80,000 PPM NOEL (DOG) 50,000 PPM. NOT
NUTAGENIC IN FOUR TESTS. TETRAGENIC NOEL (RA AND RABBIT) 40,000
PPM.

Ecology

Ecological:DEGRADABILITY (BOD): GENETRON 134A IS A GAS AT ROOM
TEMPERATURE, THERFORE, IT IS UNLIKELY TO REMAIN IN WATER. OCTANOL
WATER PARTITION COEFFICIENT: LOG P(OCTANOL/WATER)=1.06.

Transport

Transport Information:US DOT HAZARD CLASS: "REFRIGERANT GASES, N.O.S.
(TETRAFLUOROETHANE), 2.2. US DOT
ID NUMBER: UN1078.

Regulatory

Federal Regulatory Information:LISTED ON THE TSCA INVENTORY.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.