BVKTH - LUBRA GEL W/TEFLON 81-117 II/F-097
- MSDS: BVKTH
- Manufacturer: MIDCO PRODUCTS CO INC
- Product Name: LUBRA GEL W/TEFLON 81-117 II/F-097
- National Stock Number: 8030-00N051296
Product Identification
Product ID:LUBRA GEL W/TEFLON 81-117 II/F-097
MSDS Date:09/01/1993
FSC:8030
NIIN:00N051296
MSDS Number: BVKTH
Responsible Party
MARYLAND HEIGHTS, MO 63043
US
Emergency Phone: 800-424-9300(CHEMTREC)
Info Phone: 314-567-1710
Cage: 0BTA6
Contractor
Telephone: 314-567-1710
Cage: 0BTA6
Ingredients
MINERAL OIL, WHITE; (PETROLEUM)
CAS: 8042-47-5
RTECS: PY8047000
OSHA PEL N/K
ACGIH TLV: N/K
HEXANE (N-HEXANE)
CAS: 110-54-3
RTECS: MN9275000
OSHA PEL 500 PPM
ACGIH TLV: 50 PPM
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
PROPANE
CAS: 74-98-6
RTECS: TX2275000
OSHA PEL 1000 PPM
ACGIH TLV: SIMPLE ASPHYXIANT
PROPANE, 2-METHYL-; (ISOBUTANE)
CAS: 75-28-5
RTECS: TZ4300000
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES: MAY CAUSE MOD TO SEV
IRRIT. SKIN: MAY CAUSE MOD TO SEV IRRIT. CAN BE ABSORBED THRU SKIN
IN HARMFUL AMTS. INGEST: MAY CAUSE IRRIT TO INTESTINES. MAY BE
ASPIRATED INTO LUNGS IF SWALLOWED, W HICH MAY RSLT IN PULM EDEMA &
CHEM PNEUM. INHAL: DIZZ, HDCH, EXCITATION, CNS DEPRESS.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:SKIN SENSITIVITY, CHEMICAL
ALLERGIES.
First Aid
First Aid:EYES: FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES AND GET MED ATTN. SKIN: WASH WITH SOAP AND WATER. REMOVE
CONTAMD CLTHG. INGEST: DO NOT INDUCE VOMIT. GET MED ATTN. INHAL:
REMOVE TO FRES H AIR. GIVE OXYGEN IF BRTHG IS DFCLT. GET MED ATTN.
Fire Fighting
Flash Point:18.0F,-7.8C
Extinguishing Media:CO*2, STANDARD FOAM, DRY CHEMICAL, HALON.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:EXPOSURE TO TEMPS OVER 120F MAY CAUSE
BURSTING/VENTING. HEAT/FIRE MAY CAUSE HAZ FUMES: CARBON MONOXIDE.
Accidental Release
Spill Release Procedures:MOP UP, SOAK UP IMMED. REMOVE TO OUT OF DOORS.
LARGE SPILLS: EVAC AREA. CONTAIN LIQUID; TRANSFER TO CLOSED METAL
CONTAINERS. KEEP OUT OF WATER SUPPLY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT STORE WHERE TEMPS EXCEED 120F.
KEEP OUT OF REACH OF CHILDREN.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:GEN VENT RECOM TO MAINTAIN LEVEL OF HAZ INGRED TO LESS THAN
HALF OF TLV.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPVD SFTY GLASSES .
Other Protective Equipment:NONE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
Vapor Pres:40PSIG
Vapor Density:>1
Spec Gravity:0.743(H*2O=1)
Evaporation Rate & Reference:<1(BUTYL ACETATE=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:LIGHT AMBER-SWEET, ETHERAL ODOR
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZING MATERIALS.
Stability Condition to Avoid:SOURCES OF HEAT.
Hazardous Decomposition Products:OPEN FLAMES CAN CAUSE THERMAL
DEGRADATION W/EVOLUTION OF HYDROGEN CHLORIDE, PHOSGENE, AND
CHLORINE.
Disposal
Waste Disposal Methods:DISPOSE OF IN A MANNER APPROVED BY LOCAL, STATE,
AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their