BWQSZ - W45W702, DO-IT BEST EXTERIOR OIL/ALKYD WOOD (SUPDAT)

  • MSDS: BWQSZ
  • Manufacturer: THE SHERWIN WILLIAMS CO
  • Product Name: W45W702, DO-IT BEST EXTERIOR OIL/ALKYD WOOD (SUPDAT)
  • National Stock Number: 8010-00N057500
Product Identification

Product ID:W45W702, DO-IT BEST EXTERIOR OIL/ALKYD WOOD (SUPDAT)
MSDS Date:11/23/1993
FSC:8010
NIIN:00N057500
MSDS Number: BWQSZ

Responsible Party
THE SHERWIN-WILLIAMS CO
101 PROSPECT AVE N W
CLEVELAND, OH 44101
US

Emergency Phone: 216-566-2917

Info Phone: 216-566-2902

Cage: DO693

Contractor
THE SHERWIN-WILLIAMS CO
CLEVELAND, OH 44115 US

Telephone: 216-566-2902

Cage: DO693

Ingredients

53.

CAS: 64742-89-8

Fraction By Weight: 17%

OSHA PEL 100 PPM (MFR)

ACGIH TLV: 100 PPM (MFR)


KEROSENE (PETROLEUM), HYDROTREATED; (MINERAL SPIRITS).

CAS: 64742-47-8

RTECS: OA5504000

Fraction By Weight: 9%

OSHA PEL 100 PPM (MFR)

ACGIH TLV: 100 PPM (MFR)


TALC (POWDER), CONTAINING NO ASBESTOS FIBERS; (TALC)

CAS: 14807-96-6

RTECS: WW2710000

Fraction By Weight: 37%

OSHA PEL 20 MPPCF

ACGIH TLV: 2 MG/M3 RDUST


TITANIUM OXIDE; (TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 8%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


2.91 LB (348 GM).

RTECS: 9999999VO


ATTAINABLE IN WORKPLACE. REPORTS HAVE ASSOC

RTECS: 9999999ZZ


DMG. INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING

RTECS: 9999999ZZ


REGARDING POLLUTION.

RTECS: 9999999ZZ


COATING MAY CONTAIN MATLS CLASSIFIED AS NUISANCE

RTECS: 9999999ZZ


DURING SANDING/ABRADING OF DRIED FILM. IF NO SPECIFIC

RTECS: 9999999ZZ


ACGIH TLV 10 MG/M3 (TDUST), OSHA PEL 15 MG/M3

RTECS: 9999999ZZ


DUST WHICH MAY BE GENERATED FROM THIS PRODUCT,

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EXPOS MAY BE BY INHAL &/OR SKIN/EYE
CONT, DEPENDING ON CNDTNS OF USE. TO MIN EXPOS, FOLLOW RECS FOR
PROPER USE, VENT & PERSONAL PROT EQUIP. ACUTE:IRRIT OF EYES, SKIN &
RESP SYS. MAY CAUSE NERV SYS DEP RESS. EXTREME OVEREXP MAY RSLT IN
UNCON& POSS DEATH. HDCH, DIZZ, NAUS & LOSS OF COORD ARE INDICATIONS
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:OF EXCESSIVE EXPOS TO VAPS/SPRAY
MISTS. REDNESS & ITCH/BURNING SENSATION MAY INDICATE EYE/EXCESSIVE
SKIN EXPOS. CHRONIC:PRLNG OVEREXP TO SOLV INGS MAY CAUSE ADVERSE
EFTS TO LIVER & URINARY SY S. RATS EXPOS TO TITANIUM DIOXIDE DUST
AT 250 MG/M3 DEVELOPED LUNG CANCER, HOWEVER, SUCH EXPOS LEVELS ARE
NOT (ING 6)
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.

First Aid

First Aid:INHAL:REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM &
QUIET. SKIN:WASH AFFECTED AREA THOROUGHLY W/SOAP & WATER. REMOVE
CONTAMINATED CLOTHING & LAUNDER BEFORE RE-USE. EYES:FLUSH W/LARGE
AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION.
INGEST:GET MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:PMCC
Flash Point:102F,39C
Lower Limits:1%
Upper Limits:7.1%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
WATER SPRAY MAY BE INEFT. IF WATER IS USED, FOG NOZZ ARE PREF.
WATER MAY BE USED TO COOL CLSD CNTNRS(SUPDAT)
Unusual Fire/Explosion Hazard:COMBUSTIBLE. KEEP CNTNRS TIGHTLY CLSD.
ISOLATE FROM HEAT, ELEC EQUIP, SPKS & OPEN FLAME. CLSD CTNRS MAY
EXPLODE WHEN EXPOS TO EXTREME HEAT. APPLICATION (SUPDAT)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE &
REMOVE W/INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DOL STOR CATEGORY:2. CONTENTS ARE
COMBUST. KEEP AWAY FROM HEAT & FLAME. CONSULT NFPA CODE. USE APPRVD
BONDING & GROUNDING PROCS.
Other Precautions:KEEP CNTNR CLSD WHEN NOT IN USE. TRANSFER ONLY TO
APPRVD CNTNRS W/COMPLETE & APPROP LABELING. DO NOT TAKE INTERNALLY.
KEEP OUT OF REACH OF CHILDREN. USE ONLY W/ADEQ VENT. AVOID BRTHG
VAP & SPRAY MIST. AVOID CONT W/SKIN & EYES. THIS (ING 9)

Exposure Controls

Respiratory Protection:IF PERSONAL EXPOS CANNOT BE CONTROLLED BELOW
APPLIC LIMS BY VENT, WEAR A PROPERLY FITTED NIOSH/MSHA APPRVD ORG
VAP/PARTICULATE RESP FOR PROT AGAINST INGS. WHEN SANDING/ABRADING
DRIED FILM, WEAR A NIOS H/MSHA APPRVD DUST/MIST RESP FOR(ING 12)
Ventilation:LOC EXHST PREF. GEN EXHST ACCEPT IF EXPOS TO INGS IS
MAINTAINED BELOW APPLIC EXPOS LIMS. REFER TO OSHA STDS (SUPDAT)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO:PRIMER, WHITE. FIRE FIGHT PROC:TO PVNT PRESS
BUILD-UP & POSS AUTOIGNIT/EXPLO WHEN EXPOS TO EXTREME HEAT. EXPLO
HAZ:TO HOT SURFS REQS SPECIAL PRECS. DURING EMER CNDTNS OVEREXP TO
DECOMP PRODS MAY CAUSE HLTH HAZ. SYMPS MAY NOT BE IMMED APPARENT.
OBTAIN MED ATTN. VENT:1910.94, 1910.107, 1910.108.

Chemical Properties

Boiling Pt:B.P. Text:>200F,>93C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.32
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:45

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:BY FIRE:CARBON DIOXIDE, CARBON
MONOXIDE.

Disposal

Waste Disposal Methods:WASTE FROM THIS PROD MAY BE HAZ AS DEFINED UNDER
RCRA 40 CFR 261. WASTE MUST BE TESTED FOR IGNITABILITY TO DETERMINE
APPLIC EPA HAZ WASTE NUMBERS. INCIN IN APPRVD FACILITY. DO NOT
INCIN CLSD CNTNR. DI SP OF I/A/W FED, STATE & LOC REGS (ING 8)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.