BWSZF - ZYGLO PENETRANT ZL-37, 1 GAL CAN

  • MSDS: BWSZF
  • Manufacturer: MAGNAFLUX
  • Product Name: ZYGLO PENETRANT ZL-37, 1 GAL CAN
  • National Stock Number: 6850-01-306-1383
Product Identification

Product ID:ZYGLO PENETRANT ZL-37, 1 GAL CAN
MSDS Date:06/04/1993
FSC:6850
NIIN:01-306-1383
MSDS Number: BWSZF

Responsible Party
MAGNAFLUX
7300 W AINSLIE AVE
HARWOOD HTS, IL 60656
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 708-867-8000

Preparer: BRUCE C. GRAHAM

Cage: 59042

Contractor
MAGNAFLUX
CHICAGO, IL 60656 US

Telephone: 708-867-8000

Cage: 59042

Ingredients

MINERAL OIL, HYDROTREATED (SEV), HEAVY NAPHTHENIC

CAS: 64742-52-5

RTECS: PY8035001

Fraction By Weight: 30-60%

OSHA PEL N/K

ACGIH TLV: N/K


ISOCYLDIPHENYLPHOSPHATE; (ISODECYL DIPHENYL PHOSPHATE)

CAS: 29761-21-5

Fraction By Weight: 15-40%

OSHA PEL N/K

ACGIH TLV: N/K


GLYCOLS, POLYETHYLENE, MONO(NONYLPHENYL) ETHER;

CAS: 9016-45-9

RTECS: MD0900000

Fraction By Weight: 3-7%

OSHA PEL N/K

ACGIH TLV: N/K


(ORAL, RAT) 2 G/KG

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN CONTACT: CAN IRRITATE BY REMOVING
NATURAL SKIN OILS ON LONG OR REPEATED EXPOSURES. EYES: MAY CAUSE
IRRITATION. INHALATION: NOT SIGNIFICANT AT ROOM TEMPERATURES. WHEN
HEATED OR SPRAYED, PRODUCT VA PORS MAY CAUSE DIZZINESS & NAUSEA.
INGESTION: NOT SIGNIFICANT IN SMALL (MOUTHFUL) AMOUNTS.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE.

First Aid

First Aid:SKIN: WASH OFF W/SOAP & WATER. USE SOOTHING LOTION. EYES:
RINSE CAREFULLY UNDER UPPER & LOWER EYELIDS FOR AT LEAST 15 MIN
USING PLENTY OF WATER. INHAL: REMOVE TO FRESH AIR IF DIZZY OR
NAUSEATED. INGES T: DO NOT INDUCE VOMIT. ACCIDENTAL INGESTION OF SM
MOUTHFUL IS NOT EXPECTED TO CAUSE SIGNIFICANT HARM. NOTE: IN ALL
SEV CASES, CONTACT MD IMMED. LOC TELEPHONE OPERATORS CAN FURNISH
NUMBER OF (SUPDAT)

Fire Fighting

Flash Point Method:PMCC
Flash Point:200F,93C
Lower Limits:1%
Upper Limits:6%
Extinguishing Media:CARBON DIOXIDE, FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
KEEP CNTNRS COOL W/WATER SPRAY. DO NOT SPRAY WATER DIRECTLY ON
BURNING PROD. IT MAY FLOAT & SPREAD THE FIRE.
Unusual Fire/Explosion Hazard:HAZARDOUS COMBUTION PRODUCTS: SMOKE,
SOOT, OXIDES OF CARBON AND NITROGEN. DIFFICULT TO IGNITE, BUT WILL
BURN VIGOROUSLY IF ENGULFED IN FIRE.

Accidental Release

Spill Release Procedures:MOP UP OR SWEEP UP WITH ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AWAY FROM HEAT SOURCE.
Other Precautions:AVOID BREATHING SPRAY MIST. AVOID EYE CONTACT. AVOID
REPEATED OR PROLONGED SKIN CONTACT.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR WITH FILTER IF
SPRAYED IN ENCLOSED, UNVENTILATED SPACE.
Ventilation:NONE, UNLESS APPLIED AS SPRAY. USE WHERE VENTILATION WILL
CARRY SPRAY MIST AWAY FROM OCCUPIED AREAS.
Protective Gloves:NITRILE RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID PROC: REGIONAL POISON CONTROL CENTER.

Chemical Properties

Boiling Pt:B.P. Text:455F,235C
Vapor Pres:<0.10
Vapor Density:HVR/AIR
Spec Gravity:0.96
pH:NEUT
Evaporation Rate & Reference:NEGLIGIBLE
Solubility in Water:0%
Appearance and Odor:GREEN OILY LIQUID; MILD ODOR.
Percent Volatiles by Volume:NONE

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:SOOT, OXIDES OF CARBON IF HEATED TO
COMBUSTION TEMPERATURES.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,
STATE AND LOCAL REGULATIONS . AS A NON-HAZARDOUS OILY WASTE,
INCINERATE OR SEND TO WASTE HANDLER WHO CAN BLEND IT INTO SECONDARY
FUELS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.