BXBMN - CADMIUM PLATED AIRCRAFT PART

Product Identification

Product ID:CADMIUM PLATED AIRCRAFT PART
MSDS Date:12/01/1993
FSC:1620
NIIN:00-969-9616
MSDS Number: BXBMN

Responsible Party
ALLIED SIGNAL INC., AIRCRAFT LANDING SYSTEM
3520 WESTMOOR STREET
SOUTH BEND, IN 46628
US

Emergency Phone: 219-231-2000

Info Phone: 219-231-2302

Cage: 55284

Contractor
HONEYWELL INTL INC, AIRCRAFT LANDING SYSTEM ALS
SOUTH BEND, IN 46628-1373 US

Telephone: 219-231-2201

Cage: 55284

Ingredients

CADMIUM (SARA 313) (CERCLA)

CAS: 7440-43-9

RTECS: EU9800000

Fraction By Weight: TRACE

OSHA PEL 0.2 MG/M3 DUST; Z-2

ACGIH TLV: 0.01 MG/M3 DUST;9495

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:THIS METAL AIRCRAFT PART IS PLATED
W/CADMIUM. PART IS NOT HAZARDOUS. HAZARDS ARE FROM DUSTS & FUMES
GENERATED IF PART IS MACHINED. AVOID CONTACT W/CADMIUM DUST &
FUMES. ACUTE-ACUTE PNEUMONITIS & PULMO NARY EDEMA. CHRONIC-KIDNEY
DISEASE, LUNG & PROSTATE CANCER, REDUCED PULMONARY FUNCTION & LUNG
DISEASE.
Explanation of Carcinogenicity:PLATED W/CADMIUM [7440-43-9] WHICH IS
LISTED BY NTP AND IARC AND REGULATED BY OSHA AS A CARCINOGEN.
Effects of Overexposure:EYES:REDNESS OR PAIN. SKIN:IRRITATION.
INHALATION:RESPIRATORY IRRITATION, SHORTNESS OF BREATH, CHEST PAIN,
FLU-LIKE SYMPTOMS, WEAKNESS, FEVER, HEADACHE, CHILLS, SWEATING,
MUSCULAR PAIN. INGESTION:VOMI TING, ABDOMINAL PAIN, NAUSEA,
DIARRHEA,HEADACHE, & SORE THROAT.
Medical Cond Aggravated by Exposure:MFR GAVE NO INFORMATION ON MSDS.

First Aid

First Aid:GET MEDICAL ATTENTION IMMEDIATELY FOR ANY EXPOSURE. EYE:FLUSH
W/WATER TO 15 MIN. SKIN:WASH W/SOAP & WATER. REMOVE CONTAMINATED
CLOTHING & LAUNDER BEFORE REUSE. INHALED:REMOVE FROM EXPOSURE. AID
OR RES TORE BREATHING AS NEEDED. INGESTED:TREATMENT MUST BE
ADMINISTERED BY MEDICAL PERSONNEL. ADVICE TO PHYSICIAN:DO NOT
PERFORM CHELATION THERAPY.

Fire Fighting

Extinguishing Media:DRY SAND, DRY DOLOMITE, DRY GRAPHITE, OR SODIUM
CHLORIDE
Fire Fighting Procedures:WEAR A SELF-CONTAINED BREATHING APPARATUS
W/FULL FACEPIECE OPERATED IN THE POSITIVE PRESSURE MODE.
Unusual Fire/Explosion Hazard:CADMIUM DUST CREATED DURING MACHINING MAY
PRESENT A MODERATE EXPLOSION HAZARD WHEN EXPOSED TO FLAME. DUST &
STRONG OXIDIZERS MAY CASUSE FIRE OR EXPLOSION.

Accidental Release

Spill Release Procedures:(ALWAYS WEAR RECOMMENDED PERSONAL PROTECTIVE
EQUIPMENT.) ANY NORMAL CLEAN-UP PROCEDURE IS APPLICABLE. AVOID
GENERATION OF DUSTS. SPILLS & RELEASES MAY HAVE TO BE REPORTED TO
FEDERAL &/OR LOCAL AUTHOR ITIES.
Neutralizing Agent:MFR GAVE NO INFORMATION ON MSDS.

Handling

Handling and Storage Precautions:SHIPPING & STORAGE CONTAINERS
CONTAINING CADMIUM, CADMIUM COMPOUNDS, CONTAMINATERD CLOTHING &
EQUIPMENT, WASTE, SCRAP, ETC. MUST BEAR WARNING LABELS.
Other Precautions:AVOID CONTACT TO SKIN, EYES & CLOTHING. AVOID
BREATHING DUST. USE ADEQUATE VENTILATION. WASH THOROUGHLY AFTER
HANDLING.

Exposure Controls

Respiratory Protection:RESPIRATORS USED MUST BE APPROVED BY BOTH MSHA &
NIOSH. AIR PURIFYING RESPIRATORS MUST BE EQUIPPED W/HEPA FILTERS.
AIR SUPPLIED RESPIRATORS OPERATED IN POSITIVE PRESSURE MODE ARE
ALSO ACCEPTABLE. SUIT EQUIPMENT TO EXPOSURE LEVEL.
Ventilation:USE GENERAL OR LOCAL EXHAUST VENTILATION TO KEEP CADMIUM
DUST & FUME LEVELS BELOW THE TLV.
Protective Gloves:RUBBER
Eye Protection:SAFETY GOGGLES/FACE SHIELD REQUIRED
Other Protective Equipment:RUBBER APRON AND/OR SUIT REQUIRED. CLEAN
CHANGE ROOMS, HAND WASHING FACILITIES, SHOWERS SHOULD BE AVAILABLE.
Work Hygienic Practices:MFR:?. HMIS:USE GOOD CHEMICAL HYGIENE
PRACTICES. AVOID CONTACT IF AT ALL POSSIBLE. WASH THOROUGHLY AFTER
HANDLING.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:N1
NRC/State Lic Num:NONE
Appearance and Odor:MATTED TEXTURE METALLIC TO POLISHED METAL FINISH

Stability

Stability Indicator/Materials to Avoid:YES
HYDROCHLORIC &/OR NITRIC ACIDS
Stability Condition to Avoid:MFR GAVE NO INFORMATION ON MSDS.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:RCRA HAZARDOUS WASTE = D006. DISPOSE I/A/W
FEDERAL, STATE & LOCAL REGULATIONS. NOTE:THIS MATERIAL MAY HAVE
VALUE ON A RECYCLED BASIS. IF RECLAIMED, THE MATERIAL IS NOT
HAZARDOUS UNDER RCRA. THIS INFOR MATION IS FOR THE PRODUCT SHIPPED.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.