BXDXJ - CIDA-FOAM, 5409-30

  • MSDS: BXDXJ
  • Manufacturer: DEPUY INC
  • Product Name: CIDA-FOAM, 5409-30
  • National Stock Number: 6840-00N058124
Product Identification

Product ID:CIDA-FOAM, 5409-30
MSDS Date:11/09/1990
FSC:6840
NIIN:00N058124
MSDS Number: BXDXJ

Responsible Party
DEPUY INC
WARSAW, IN 46581-0988
US

Emergency Phone: 219-267-8143

Info Phone: 219-267-8143

Preparer: KENNETH G ROBERTS

Cage: 0CMX1

Contractor
DEPUY INC
988 WARSAW, IN 46581-0988 US

Telephone: 219-267-8143

Cage: 0CMX1

Ingredients

AMMONIUM, BENZYLDIMETHYLTETRADECYL-, CHLORIDE; (N-ALKYL

CAS: 139-08-2

RTECS: BO7150000

Fraction By Weight: 0.11%

OSHA PEL N/K

ACGIH TLV: N/K


AMMONIUM CHLORIDE)

RTECS: 9999999ZZ


DODECYL DIMETHYL ETHYLBENZYL AMMONIUM CHLORIDE; (N-ALKYL

CAS: 27479-28-3

OSHA PEL N/K

ACGIH TLV: N/K


BENZYL AMMONIUM CHLORIDE)

RTECS: 9999999ZZ


BUTANE

CAS: 106-97-8

RTECS: EJ4200000

Fraction By Weight: 1-10%

OSHA PEL 800 PPM

ACGIH TLV: 800 PPM


PROPANE

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 1-10%

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT


ETHANOL, 2-BUTOXY-; (2-BUTOXYETHANOL)

CAS: 111-76-2

RTECS: KJ8575000

Fraction By Weight: 1-10%

OSHA PEL S, 50 PPM

ACGIH TLV: S, 25 PPM

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION:NO ADVERSE REACTION
EXPECTED. EYES:MAY CAUSE EYE IRRITATION. SKIN:MAY CAUSE SKIN
IRRITATION. HARMFUL IF ABSORBED. INGESTION:MAY BE HARMFUL.
CHRONIC:"ANIMAL STUDIES CLEARLY DEMONSTRATED DOSE -RELATED ADVERSE
EFTS ON THE CNS, HEMATOPOIETIC TISS, BLOOD, KIDNEYS & LIVER, ASSOC
W/ADMIN OF ETHYLENE(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:GLYCOL MONO BUTYL ETHER (EGBE).
(EXTRACTED FROM DHHS (NIOSH) PUBLICATION NO 90-118) ".
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALATION:MOVE TO FRESH AIR. EYES:IMMEDIATELY FLUSH WITH
PLENTY OF WATER FOR AT LEAST 15 MINUTES. CALL A PHYSICIAN IF
IRRITATION PERSISTS. SKIN:FLUSH WITH PLENTY OF WATER. REMOVE
CONTAMINATED CLOTHIN G. CALL A PHYSICIAN IF IRRITATION PERSISTS.
WASH CLOTHING BEFORE REUSE. INGESTION:GIVE VICTIM A GLASS OF WATER.
CALL A PHYSICIAN.

Fire Fighting

Flash Point Method:TCC
Flash Point:NONE
Extinguishing Media:WATER, DRY CHEMICAL, CARBON DIOXIDE FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. KEEP CNTNRS COOL WITH WATER SPRAY. USE SHIELDING TO PROT PERS
FROM BURSTING, VENTING/RUPTURING CNTNRS.
Unusual Fire/Explosion Hazard:AT TEMPERATURES ABOVE 130F (54C)
CONTAINERS MAY BURST, VENT OR RUPTURE.

Accidental Release

Spill Release Procedures:CONTAIN SPILL. DO NOT CONTAMINATE FOOD, FEED
OR WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY AREA. KEEP AWAY
FROM HEAT AND FLAMES. DO NOT PUNCTURE OR INCINERATE CONTAINERS.
KEEP OUT OF REACH OF CHILDREN.
Other Precautions:CONTAINS 2-BUTOXYETHANOL WHICH CAUSES HEMOLYSIS OF
RED BLOOD CELLS IN SOME SPECIES OF ANIMALS. IN HUMANS, THESE BLOOD
EFFECTS DID NOT OCCUR AT EXPOSURE LEVELS UP TO 200 PPM.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN . NONE REQUIRED.
Ventilation:MECHANICAL (GENERAL):ADEQUATE.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:NONE.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Vapor Pres:18
Vapor Density:<1
Spec Gravity:1.01 (H*2O=1)
Evaporation Rate & Reference:<1
Solubility in Water:100%
Appearance and Odor:LIGHT YELLOW LIQUID/SPRAY; PLEASANT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:ELEVATED TEMPERATURES.
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE,
NITROGEN OXIDES.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE
AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.