BXQNJ - IRON STANDARD 1000 PPM, I-135

  • MSDS: BXQNJ
  • Manufacturer: RED BIRD SERVICE
  • Product Name: IRON STANDARD 1000 PPM, I-135
  • National Stock Number: 6810-00N059526
Product Identification

Product ID:IRON STANDARD 1000 PPM, I-135
MSDS Date:08/11/1992
FSC:6810
NIIN:00N059526
MSDS Number: BXQNJ

Responsible Party
RED BIRD SERVICE
205 WESTERN AVE
OSGOOD, IN 47037
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 800-428-3502

Preparer: GENE C FEITH

Cage: 0H0Z7

Contractor
RED BIRD SERVICE
OSGOOD, IN 47037 US

Telephone: 812-689-4040;800-428-3502

Cage: 0H0Z7

Ingredients

FERRIC CHLORIDE (CERCLA)

CAS: 7705-08-0

RTECS: LJ9100000

Fraction By Weight: <1%

OSHA PEL 1 MG (FE)/M3

ACGIH TLV: 1 MG (FE)/M3

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


HYDROCHLORIC ACID; (HYDROGEN CHLORIDE) (SARA 302/313)

CAS: 7647-01-0

RTECS: MW4025000

Fraction By Weight: <1%

OSHA PEL C 5 PPM

ACGIH TLV: C 5 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: BALANCE

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: THIS SOLUTION MAY CAUSE AN
IRRITATION OF THE EYES OR SKIN.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH W/WATER FOR AT LEAST 15 MINUTES INCLUDING UNDER
EYELIDS. IF IRRITATION DEVELOPS, CONTACT MD. SKIN: WASH AFFECTED
AREA W/SOAP & WATER. CONTACT MD IF IRRITATION DEVELOPS. INHAL:
REMOVE TO FR ESH AIR. INGEST: DILUTE W/SEVERAL GLASSES OF WATER &
INDUCE VOMITING. FOLLOW W/MILK OF MAGNESIA. CONTACT MD. CONTACT
LENSES POSE SPECIAL HAZARD. SOFT LENSES ABSORB & ALL LENSES
CONCENTRATE IRRITANTS.

Fire Fighting

Flash Point:NON-FLAMMABLE.
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:DIKE SPILL, TAKE UP WITH ABSORBENT AND
CONTAINERIZE FOR PROPER DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN WELL CLOSED CONTAINERS UNDER
NORMAL LABORATORY CONDITIONS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NOT EXPECTED TO BE REQUIRED UNDER NORMAL
LABORATORY USE. USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:GENERAL VENTILATION IS ADEQUATE.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:EYEWASH FOUNTAINS AND SAFETY SHOWERS SHOULD
BE AVAILABLE IN NEARBY WORK AREA.
Work Hygienic Practices:LAUNDER ALL CONTAM CLTHG BEFORE REUSE.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Vapor Pres:14
Vapor Density:0.7
Evaporation Rate & Reference:>1 (BUTYL ACETATE=1)
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR YELLOW LIQUID WITH NO ODOR
Percent Volatiles by Volume:99+

Stability

Stability Indicator/Materials to Avoid:YES
NONE FOUND.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CHLORINE COMPOUNDS.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE &
FEDERAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.