CBBSG - I-125 ISOJEX REFERENCE STANDARD

  • MSDS: CBBSG
  • Manufacturer: MALLINCKRODT MEDICAL INC
  • Product Name: I-125 ISOJEX REFERENCE STANDARD
  • National Stock Number: 6550-00N030336
Product Identification

Product ID:I-125 ISOJEX REFERENCE STANDARD
MSDS Date:01/01/1993
FSC:6550
NIIN:00N030336
MSDS Number: CBBSG

Responsible Party
MALLINCKRODT MEDICAL INC
2703 WAGNER PLACE
MARYLAND HEIGHTS, MO 63043
US

Emergency Phone: 314-344-3800

Info Phone: 314-344-3800

Cage: FO650

Contractor
MALLINCKRODT MEDICAL INC
MARYLAND HEIGHTS, MO 63043-3421 US

Telephone: 314-770-7800/314-895-2000

Cage: FO650

Ingredients

HEAVIER SHIELDING. AVOID CONTACT W/THE RADIOACTIVE

RTECS: 9999999ZZ


POTASSIUM IODIDE

CAS: 7681-11-0

RTECS: TT2975000

Fraction By Weight: 0.14%

OSHA PEL N/K

ACGIH TLV: N/K


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: >98.5%

OSHA PEL N/K

ACGIH TLV: N/K


APPROP TO GOVT AGENCY AUTHORIZED TO LISCENSE USE

RTECS: 9999999ZZ


WITHIN ITS CNTNR OR WITHIN HVR SHIELDING. AVOID CONT

RTECS: 9999999ZZ


TO RADIA. RADIOACTIVE MATLS ARE SUBSTANCES KNOWN TO

RTECS: 9999999ZZ


THIS PROD CNTNS SUBSTANCE

RTECS: 9999999ZZ


W/WATER FOR AT LEAST 15 MIN OR UNTIL NO MORE

RTECS: 9999999ZZ


PROCEDURES (SOPS) ESTABLISHED FOR YOUR FACILITY

RTECS: 9999999ZZ


IF MEDICAL WASTE IS INVOLVED, SUCH AS

RTECS: 9999999ZZ


AS A BIOHAZARD & DISPOSED OF ACCORDINGLY. IF NOT

RTECS: 9999999ZZ


STANDARDS ARE CONSIDERED NON-HAZARDOUS. CONSULT

RTECS: 9999999ZZ


SHOULD BE USED. STORAGE & DISP OF PROD

RTECS: 9999999ZZ


W/APPROP REGS OF FEDERAL OR STATE GOVT AGENCY

RTECS: 9999999ZZ


THE USE OF THIS RADIONUCLIDE. THE VIAL

RTECS: 9999999ZZ


RADIOACTIVE IODINE; (AQUEOUS SODIUM IODIDE I-125) SPEC

CAS: 9048-46-8

Fraction By Weight: <1%

OSHA PEL N/K

ACGIH TLV: N/K


SODIUM HYDROXIDE (CERCLA)

CAS: 1310-73-2

RTECS: WB4900000

Fraction By Weight: 0.07%

OSHA PEL 2 MG/M3

ACGIH TLV: C 2 MG/M3

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


SODIUM SULFITE

CAS: 7757-83-7

RTECS: WE2150000

Fraction By Weight: 0.20%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHALATION:VERY SMALL FRACTION
OF IODINATED ALBUMIN COULD BREAK DOWN & EMIT RADIOACTIVE FUMES
CONTAINING I-125. INGESTION:MAY CAUSE ASYMPTOMATIC PHYSIOLOGICAL
UPTAKE BY THYROID GLAND OR OTHER TI SSUES. EYE:NO ADVERSE EFFECT
EXPECTED, BUT MAY CAUSE MECHANICAL IRRITATION. CHRONIC:HEALTH RISKS
ASSOC (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:WITH CHRONIC RADIATION EXPOSURE
(CANCER, LEUKEMIA, GENETIC AND TERATOGENIC EFFECTS) ARE BELIEVED TO
INVOLVE LEVELS OF RADIATION EXPOSURE WHICH ARE MUCH HIGHER THAN
THOSE PERMITTED OCCUPATIONA LLY.
Medical Cond Aggravated by Exposure:NO INFORMATION FOUND.

First Aid

First Aid:REMOVE PROMPTLY ANY CONTAM FROM SKIN, EYES/CLTHG.
INHAL:REMOVE TO FRESH AIR. SUPPORT BRTHG (GIVE O*2/ARTF RESP) .
INGEST:NOTIFY RADIA SFTY PERS IMMED. AMT OF I-125 IN THYROID GLAND
SHOULD BE ASS ESSED & DOCUMENTED. THYROID BLOCKING AGENT MAY BE
WARRANTED & ADMIN UNDER DIRECTION OF PHYS. SKIN:WASH AFFECTED AREA
THORO W/SOAP & WATER UNTIL NO MORE RADIOACTIVITY CAN BE REMOVED.
ALWAYS (SUPDAT)

Fire Fighting

Extinguishing Media:USE ANY MEANS SUITABLE FOR EXTINGUISHING
SURROUNDING FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT CONSIDERED TO BE AN EXPLOSION HAZARD.

Accidental Release

Spill Release Procedures:IF PROD IS RECEIVED IN LEAKING CNDTN/ANY LOSS
OR RELEASE OF RADIOACTIVE CONTENTS OCCURS, NOTIFY YOUR RADIATION
SFTY DEPARTMENT & MALLINCKRODT @ (314)344-3800. ALL CLEANUP
OPERATIONS SHOULD BE PERFORME D ACCORDING TO STD OPERATING
PROC(SOPS)(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE @ 15C-30C. HNDLG TIME SHOULD BE
KEPT TO MIN & APPROP SHIELDING SHOULD BE USED. HNDLG DEVICES SUCH
AS SYRINGE SHIELDS & TONGS SHOULD BE USED.
Other Precautions:STOR & DISP OF PROD SHOULD BE CONTROLLED IN MANNER
WHICH IS IN COMPLIANCE W/APPROP REGS OF FED/ST GOVT AGENCY
AUTHORIZED TO LICENSE USE OF RADIONUCLIDE. CAUTION!RADIOACTIVE
DRUGS MUST BE HNDLD BY QUAL IFIED PERS IN CONFORMITY W/REGS (ING 6)

Exposure Controls

Respiratory Protection:NOT EXPECTED TO REQ PERSONAL RESP USAGE.
NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN
.
Ventilation:PROPERLY SEALED CONTAINERS ARE NOT EXPECTED TO REQUIRE ANY
SPECIAL VENTILATION.
Protective Gloves:PLASTIC, LATEX, OR RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:LABCOAT. ANSI APPRVD EMERGENCY EYE WASH &
DELUGE SHOWER .
Work Hygienic Practices:NO SMKNG, EATING/DRINKING SHOULD BE ALLOWED IN
ANY AREA WHERE RADIOACTIVE MATLS ARE HANDLED OR STORED.
Supplemental Safety and Health
FIRST AID PROC:BLOT DRY. DO NOT ABRADE SKIN. EYES:WASH W/WATER FOR @
LEAST 15 MINUTES OR UNTIL NO MORE RADIOACTIVITY CAN BE REMOVED.
NOTIFY RADIATION SFTY PERS. SPILL RELEASE PROC:ESTABLISHED FOR YOUR
FACILITY. RADIOACTIVE WASTE SHOULD BE DISPOSED OF ACCORDING TO
SOPS ESTABLISHED BY YOUR RADIATION SAFETY OFFICER.

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Spec Gravity:SEE ING 1
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:SOLUBLE
Appearance and Odor:CLEAR, COLORLESS LIQUID IN A 4 ML GLASS SCREW-CAP
VIAL, ODORLESS.

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:STABLE UNDER ORDINARY CONDITIONS OF USE
AND STORAGE.
Hazardous Decomposition Products:MAY EMIT RADIOACTIVE FUMES CONTAINING
I-125 WHEN HEATED TO DECOMPOSITION.

Disposal

Waste Disposal Methods:ENSURE COMPLIANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.