CBNDZ - ITEK MEGA PLATE FOUNTAIN, 38776

Product Identification

Product ID:ITEK MEGA PLATE FOUNTAIN, 38776
MSDS Date:10/15/1993
FSC:6850
NIIN:00N071122
MSDS Number: CBNDZ

Responsible Party
A B DICK CO GRAPHIC SYSTEMS DIV
811 JEFFERSON RD
ROCHESTER, NY 14623
US

Emergency Phone: 312-763-1900

Info Phone: 800-752-5139

Preparer: KENNETH W PINTER

Cage: 1BT21

Contractor
DICK A B CO
ROCHESTER, NY 14623-3211 US

Telephone: 716-475-9050

Cage: 1BT21

Ingredients

WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 70-90%

OSHA PEL N/K

ACGIH TLV: N/K


POLYETHYLENE GLYCOL #300

CAS: 25322-68-3

RTECS: TQ3630000

Fraction By Weight: 5-10%

OSHA PEL N/K

ACGIH TLV: N/K


ETHYLENE GLYCOL (SARA 313) (CERCLA)

CAS: 107-21-1

RTECS: KW2975000

Fraction By Weight: 5-10%

OSHA PEL C 50 PPM (MFR)

ACGIH TLV: C 50 PPM, VAPOR

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


SILICA GEL; (LLUDOX AM(COLLODIAL SILICA)

CAS: 112945-52-5

RTECS: VV7310000

Fraction By Weight: 1-5%

OSHA PEL N/K

ACGIH TLV: N/K


TRIPHOSPHORIC ACID, PENTASODIUM SALT; (SODIUM PHOSPHATE)

CAS: 7758-29-4

RTECS: YK4570000

Fraction By Weight: 1-5%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INGEST:SWALLOWING ETHYLENE
GLYCOL MAY CAUSE ABDOMINAL DISCOMFORT OR PAIN, EUPHORIA, CENTRAL
NERVOUS SYSTEM DEPRESSION, OLIGURIA, URENIA. KIDNEY DAMAGE POSSIBLE
ETHYLENE GLYCOL MAY BE FATAL. EYE: DISCOMFORT WITH POSSIBLE
TRANSIENT CONJUNCTIVITIS. SERIOUS CORNEAL INJURY NOT ANTICIPATED.
INHALATION: (EFTS OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:ETHYLENE GLYCOL MISTS MAY IRRITATE
NOSE AND THROAT. HIGH VAPOR CONCENTRATIONS CAUSED BY HEATING IN
POORLY VENTILATED AREA MAY PRODUCE NAUSEA, VOMITING, HEADACHE AND
DIZZINESS. CHRONIC:MAY CAU SE NOSE AND THROAT IRRITATION. MAY CAUSE
KIDNEY DAMAGE.
Medical Cond Aggravated by Exposure:NONE KNOWN.

First Aid

First Aid:INGEST:IF CONSCIOUS, GIVE 2 GLASSES OF WATER. DO NOT INDUCE
VOMITING. GET MEDICAL ATTN. EYE:FLUSH THOROUGHLY WITH WATER FOR AT
LEAST 15 MINUTES. OBTAIN MEDICAL ATTENTION. SKIN:REMOVE CONTAMD
CLOTHING & FLUSH EXPOSED AREA THOROUGHLY WITH WATER. INHAL:REMOVE
TO FRESH AIR. IF DISCOMFORT PERSISTS CONTACT PHYSICIAN.

Fire Fighting

Flash Point:NONE
Extinguishing Media:NONE. MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:NONE. USE NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:DIKE THE SPILL AND SOAK UP WITH ABSORBANT
MATERIAL. PREVENT LIQUID FROM ENTERING SEWERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AT ROOM TEMPERATURE. LAB COAT.
Other Precautions:CONTACT LENS WEARERS SHOULD WEAR REGULAR GLASSES.

Exposure Controls

Respiratory Protection:NONE REQUIRED. NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:LOCAL & MECHANICAL (GENERAL) EXHAUST:RECOMMENDED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:LAB COAT. ANSI APPPRVD EMERGENCY EYE WASH &
DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:>212F,>100C
Spec Gravity:1.027 (H*2O=1)
pH:5.5
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:COMPLETE
Appearance and Odor:PINK LIQUID, ODORLESS.
Percent Volatiles by Volume:>80

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:NONE.

Disposal

Waste Disposal Methods:IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.