CBNFC - ITEK MEGA PLATE STABILIZER, 38753

Product Identification

Product ID:ITEK MEGA PLATE STABILIZER, 38753
MSDS Date:01/10/1994
FSC:6850
NIIN:00N071124
MSDS Number: CBNFC

Responsible Party
A B DICK CO GRAPHIC SYSTEMS DIV
811 JEFFERSON RD
ROCHESTER, NY 14623
US

Emergency Phone: 312-763-1900

Info Phone: 800-752-5139

Preparer: KENNETH W PINTER

Cage: 1BT21

Contractor
DICK A B CO
ROCHESTER, NY 14623-3211 US

Telephone: 716-475-9050

Cage: 1BT21

Ingredients

WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 80-90%

OSHA PEL N/K

ACGIH TLV: N/K


POTASSIUM PHOSPHATE, MONOBASIC

CAS: 7778-77-0

Fraction By Weight: 5-10%

OSHA PEL N/K

ACGIH TLV: N/K


(ORAL,RAT) 4 G/KG

CAS: 107-21-1

RTECS: KW2975000

Fraction By Weight: 1-5%

OSHA PEL N/K

ACGIH TLV: C 50 PPM, VAPOR

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


0.25 LBS/GAL

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:SEE INGREDIENT 3
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INGESTION:MAY CAUSE ABDOMINAL
DISCOMFORT OR PAIN, DIZZINESS, LUMBAR PAIN, OLIGURIA AND CENTRAL
NERVOUS SYSTEM DEPRESSION. MAY CAUSE KIDNEY DAMAGE. ETHYLENE GLYCOL
MAY BE FATAL. EYE:DISCOMFORT WI TH POSSIBLE TRANSIENT
CONJUNCTIVITIS. SERIOUS CORNEAL INJURY NOT ANTICIPATED.
INHALATION:MAY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:CAUSE IRRITATION TO NOSE, THROAT. HIGH
VAPOR CONCENTRATIONS MAY CAUSE NAUSEA, VOMITING HEADACHE AND
DIZZINESS. EFTS OF OVEREXP:EYE IRRITATION, NAUSEA, HEADACHE,
DIZZINESS, MAY CNS DEPRESSION. KIDNEY DAMAGE.
Medical Cond Aggravated by Exposure:NONE.

First Aid

First Aid:INGEST:IF CONSCIOUS, GIVE TWO GLASSES OF WATER. DO NOT INDUCE
VOMITING. SEEK MEDICAL ATTENTION. EYE:FLUSH WITH WATER THORO FOR AT
LEAST 15 MINUTES, SEEK MEDICAL ATTENTION. SKIN:REMOVE CONTAMD
CLOTHING & FLUSH EXPOSED AREA THOROUGHLY W/WATER. INHAL:REMOVE TO
FRESH AIR. IF DISCOMFORT PERSISTS, CALL A PHYSICIAN.

Fire Fighting

Flash Point:NONE
Extinguishing Media:NONE. MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:NONE. USE NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:DIKE THE SPILL AND SOAK UP WITH ABSORBANT
MATERIAL. PREVENT LIQUID FROM ENTERING SEWERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AT ROOM TEMPERATURE. LAB COAT.
Other Precautions:CONTACT LENS WEARERS SHOULD WEAR REGULAR GLASSES.

Exposure Controls

Respiratory Protection:NONE REQUIRED. NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:MECHANICAL (GENERAL): ACCEPTABLE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:LAB COAT. ANSI APPRVD EMERGENCY EYE WASH &
DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:>212F,>100C
Spec Gravity:1.065
pH:5.55
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS LIQUID, ODORLESS.

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:NONE.

Disposal

Waste Disposal Methods:IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their