CBYYX - AMERCOR 8760 CORROSION INHIBITOR

  • MSDS: CBYYX
  • Manufacturer: ASHLAND CHEMICAL INC
  • Product Name: AMERCOR 8760 CORROSION INHIBITOR
  • National Stock Number: 6850-00N072808
Product Identification

Product ID:AMERCOR 8760 CORROSION INHIBITOR
MSDS Date:05/31/1989
FSC:6850
NIIN:00N072808
MSDS Number: CBYYX

Responsible Party
ASHLAND CHEMICAL INC
ONE DREW PLAZA
BOONTON, NJ 07005
US

Emergency Phone: 800-274-5263

Info Phone: 201-263-7600

Cage: DO048

Contractor
DREW CHEMICAL CORP,DIV OF ASHLAND CHEMICAL CO
BOONTON, NJ 07005 US

Telephone: 606-324-1133

Cage: 52454

Ingredients

CYCLOHEXYLAMINE (SARA 302)

CAS: 108-91-8

RTECS: GX0700000

Fraction By Weight: 10-25%

OSHA PEL 10 PPM

ACGIH TLV: 10 PPM; 9495


MORPHOLINE

CAS: 110-91-8

RTECS: QD6475000

Fraction By Weight: 10-25%

OSHA PEL S, 20 PPM

ACGIH TLV: S, 20 PPM; 9495


IF

RTECS: 9999999ZZ


IS DIFFICULT, ADMINISTER OXYGEN. IF BREATHING HAS

RTECS: 9999999ZZ


QUIET AND GET MEDICAL ATTENTION.

RTECS: 9999999ZZ


SPILL UNTIL CLEAN-UP HAS BEEN COMPLETED. STOP

RTECS: 9999999ZZ


STREAMS OR OTHER BODIES OF WATER. PREVENT FROM

RTECS: 9999999ZZ


PUMP/VACUUM TRANSFER SPILLED PROD TO CLEAN CNTNRS FOR

RTECS: 9999999ZZ


ABSORB, SOIL & OTHER MATLS TO CNTNRS FOR DISP. PVNT

RTECS: 9999999ZZ


RUN-OFF OCCURS, NOTIFY PROPER AUTHORITIES AS

RTECS: 9999999ZZ


ALL HAZARD PRECAUTIONS GIVEN IN THIS DATA SHEET

RTECS: 9999999ZZ


CNDTNS (SEE YOUR INDUSTRIAL HYGIENIST).

RTECS: 9999999ZZ


AND FULL LENGTH FACESHIELD .

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES: CAUSES BURNS. SKIN: VAPOR
CAN CAUSE IRRITATION AND DERMATITIS: LIQUID CAN CAUSE BURNS.
INHALATION: EXCESSSIVE INHALATION OF VPAORS CAN CAUSE NASAL AND
RESPIRATORY IRRITATION. INGESTION: C AN CAUSE SEVERE
GASTROINTESTINAL IRRITATION, VOMITING, DIARRHEA, SWEATING,
WEAKNESS, HEADACHE. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: OVEREXPOSURE TO THIS MATERIAL (OR ITS
COMPONENTS) HAS APPARENTLY BEEN FOUND TO CAUSE THE FOLLOWING
EFFECTS IN LABORATORY ANIMALS: LIVER ABNORMALITIES, KIDNEY DAMAGE,
EYE DAMAGE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN:IMMED FLUSH EXPOSED AREA W/H*2O FOR AT LEAST 15 MIN, GET
MED ATTN. REMOVE CONTAMD CLTHG. LAUNDER CONTAMD CLTHG BEFORE
RE-USE. REMOVE CONTAMD SHOES PROMPTLY. DISCARD SHOES SATURATED
W/THIS PROD. E YES:IMMED FLUSH W/LRG AMTS OF H*2O FOR AT LEAST 15
MIN, LIFTING UPPER & LOWER LIDS OCCAS. GET IMMED MED ATTN. IF MD IS
NOT IMMED AVAIL, CONTINUE FLUSHING W/H*2O. INGEST:IMMED DRINK TWO
(SUPDAT)

Fire Fighting

Flash Point Method:PMCC
Flash Point:>128F,>53C
Lower Limits:1.8%
Extinguishing Media:ALCOHOL FOAM OR WATER FOG OR CARBON DIOXIDE OR DRY
CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:VAPS ARE HVR/AIR & MAY TRAVEL ALONG THE
GROUND/BE MOVED BY VENT & IGNITED BY HEAT, PILOT LIGHTS, OTHER
FLAMES & IGNIT SOURCES AT LOCATIONS DIST FROM (SUPDAT)

Accidental Release

Spill Release Procedures:SMALL SPILL:ABSORB LIQ ON VERMICULITE, FLOOR
ABSORB/OTHER ABSORB MATL & TRANSFER TO HOOD. LARGE SPILL:ELIM ALL
IGNIT SOURCES (FLARES, FLAMES INCLUDING PILOT LIGHTS, ELEC SPARKS).
PERSONS NOT WEARING P ROT EQUIP SHOULD BE EXCLUDED FROM AREA OF
(ING 6)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT USE SODIUM NITRITE OR OTHER
NITROSATING AGENTS IN FORMULATIONS CONTAINING THIS PRODUCT.
SUSPECTED CANCER-CAUSING NITROSAMINES COULD BE FORMED.
Other Precautions:KEEP FROM FREEZING. WHEN OPENING, REMOVE CLOSURES
CAREFULLY TO RELIEVE POSS INTERNAL PRESS. NEVER USE PRESS TO EMPTY.
CNTNRS OF THIS MATL MAY BE HAZ WHEN EMPTIED. SINCE EMPTIED CNTNRS
RETAIN PROD RESI DUES (VAP, LIQ, AND/OR SOLID), (ING 11)

Exposure Controls

Respiratory Protection:IF WORKPLACE EXPOS LIM(S) OF PROD/ANY COMPONENT
IS EXCEEDED (SEE SECTION II), NIOSH APPRVD AIR SUPP RESP IS ADVISED
IN ABSENCE OF PROPER ENVIRON CTL. OSHA REGS ALSO PERMIT OTHER NIOSH
APPRVD RESPS (NE G PRESS TYPE) UNDER SPECIFIED (ING 12)
Ventilation:PROVIDE SUFFICIENT MECHANICAL (GENERAL AND/OR LOCAL
EXHAUST) VENTILATION TO MAINTAIN EXPOSURE BELOW TLV(S).
Protective Gloves:NATURAL RUBBER.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(ING 13)
Other Protective Equipment:ANSI APPRVD EMER EYE WASH & DELUGE SHOWER .
TO PREVENT SKIN CONTACT, WEAR IMPERVIOUS CLOTHING AND BOOTS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
PH:12.3-13.3. EXPLO HAZ:MATL HNDLG POINT. NEVER USE WELDING/CUTTING
TORCH ON/NEAR DRUM (EVEN EMPTY) BECAUSE PROD (EVEN JUST RESIDUE)
CAN IGNITE EXPLOSIVELY. FIRST AID PROC:GLASSES OF H*2O & INDUCE VOM
IT BY EITHER GIVING IPECAC SYRUP/BY PLACING FINGER AT BACK OF
THROAT. NEVER GIVE ANYTHING BY MOUTH TO AN (ING 3)

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Vapor Pres:17.5 @ 20C
Vapor Density:HVR/AIR
Spec Gravity:0.98-1.000
pH:SUPDAT
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:CLEAR WATER WHITE LIQUID
Percent Volatiles by Volume:>95

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH: STRONG OXIDIZING AGENTS, STRONG ALKALIES, STRONG
ORGANIC ACIDS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL DECOMP/COMBUSTION MAY
PRODUCE:CARBON DIOXIDE & CARBON MONOXIDE, NITROGEN COMPOUNDS,
VARIOUS HYDROCARBONS, ETC.

Disposal

Waste Disposal Methods:SMALL SPILL: DEPOSIT IN A LANDFILL IN ACCORDANCE
WITH LOCAL,STATE AND FEDERAL REGULATIONS. LARGE SPILLS: DEPOSIT IN
A LANDFILL IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.