CGDWX - MAC'S BRAKE & ELECTRICAL MOTOR CLEANER 4700

  • MSDS: CGDWX
  • Manufacturer: VALVOLINE INC
  • Product Name: MAC'S BRAKE & ELECTRICAL MOTOR CLEANER 4700
  • National Stock Number: 6850-00-000-0247
Product Identification

Product ID:MAC'S BRAKE & ELECTRICAL MOTOR CLEANER 4700
MSDS Date:10/06/1989
FSC:6850
NIIN:00-000-0247
Kit Part:Y
MSDS Number: CGDWX

Responsible Party
VALVOLINE INC
LEXINGTON, KY 40512
US

Emergency Phone: 606-264-7000

Info Phone: 606-264-7000

Cage: GO029

Contractor
VALVOLINE OIL CO
14000 LEXINGTON, KY 40512 US

Telephone: 606-357-7206 / 800-274-5263

Cage: 72527

Ingredients

CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: 1-5%

OSHA PEL 5000 PPM

ACGIH TLV: 5000PPM/30000STEL;96


METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA 313)

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 58%

OSHA PEL 350 PPM

ACGIH TLV: 350 PPM/450STEL;9596

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PERCHLOROETHYLENE (TETRACHLOROETHYLENE) (SARA 313) (CERCLA)

CAS: 127-18-4

RTECS: KX3850000

Fraction By Weight: 39%

OSHA PEL 100 PPM, Z-2

ACGIH TLV: 25PPM/100STEL,A3; 96

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES-CAN CAUSE SEVERE IRRITATION.
SKIN-PROLONGED OR REPEATED SKIN CONTACT CAN CAUSE MODERATE
IRRITATION, DEFATTING, DERMATITIS. BREATHING-CAN CAUSE NASAL &
RESPIRATORY IRRITATION, CENTRAL NERVOUS SYST EM EFFECTS.
SWALLOWING-CAN CAUSE GASTROINTESTINAL IRRITATION.
Explanation of Carcinogenicity:PERCCLOROETHYLENE HAS BEEN SHOWN TO
CAUSE CANCER IN LAB ANIMALS. IT HAS BEEN LISTED AS A POSSIBLE
CARCINOGEN BY IARC,NTP
Effects of Overexposure:EYE-REDNESS, TEARING, BLURRED VISION.
BREATHING-DIZZINESS, WEAKNESS, FATIGUE, NAUSEA, HEADACHE & POSSIBLY
UNCONSCIOUSNESS & EVEN DEATH. SWALLOWING-CAN CAUSE NAUSEA, VOMITING
AND DIARRHEA.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN-THOROUGHLY WASH EXPOSED AREA WITH SOAP & WATER. REMOVE
CONTAMINATED CLOTHES. EYES-FLUSH WITH LARGE AMOUNTS OF WATER, GET
MEDICAL ATTENTION. SWALLOWED-DO NOT INDUCE VOMITING, IMMEDIATELY
DRINK 2 G LASSES OF WATER. CALL A PHYSICIAN OR TRANSPORT TO AN
EMERGENCY FACILITY. BREATHE-REMOVE TO FRESH AIR. IF BREATHING IS
HARD, GIVE OXYGEN. IF BREATHING HAS STOPPED, PERFORM CPR. KEEP
WARM. SEE DOCTOR.

Fire Fighting

Extinguishing Media:REGULAR FOAM OR CARBON DIOXIDE OR DRY CHEMICAL.
Fire Fighting Procedures:WATER MAY BE USED TO KEEP FIRE-EXPOSED
CONTAINERS COOL UNTIL FIRE IS OUT. WEAR SELF-CONTAINED BREATHING
APPARATUS WITH FULL FACEPIECE OPERATED IN POSITIVE MODE.
Unusual Fire/Explosion Hazard:MAY FORM TOXIC MATERIALS: CARBON DIOXIDE
AND CARBON MONOXIDE, HYDROGEN CHLORIDE, PHOSGENE, ETC.

Accidental Release

Spill Release Procedures:ABSORB LIQUID ON PAPER, VERMICULITE, FLOOR
ABSORBENT OR OTHER ABSORBENT MATERIAL AND TRASNFER TO HOOD.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL, DRY PLACE.
Other Precautions:NONE

Exposure Controls

Respiratory Protection:A NIOSH/MSHA APPROVED AIR SUPPLIED RESPIRATOR IS
ADVISED IN ABSENCE OF PROPER ENVIRONMENTAL CONTROLS. OSHA
REGULATIONS ALSO PERMIT OTHER NIOSH/MSHA RESPIRATORS (NEGATIVE
PRESSURE TYPE) UNDER SPECIFIC CONDITIONS.
Ventilation:PROVIDE SUFFICIENT MECHANICAL (GENERAL AND/OR LOCAL
EXHAUST) VENTILATION TO MAINTAIN EXPOSURE BELOW TLV.
Protective Gloves:RESISTANT GLOVES, PVC ALCOHOL, VITON.
Eye Protection:CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:AS APPOROPIATE.
Work Hygienic Practices:WASH THOROUGJLY AFTER HANDLING.
Supplemental Safety and Health
DOT HAZARD CLASSIFICATION: NON-FLAMMABLE COMPRESSED GAS.

Chemical Properties

HCC:G3
Boiling Pt:B.P. Text:161F,72C
Vapor Pres:100 MMHG
Vapor Density:>AIR
Spec Gravity:1.4-1.440
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:LIQUID. HOMOGENOUS SOLUTION.

Stability

Stability Indicator/Materials to Avoid:YES
REACTIVE METALS SUCH AS ALUMINUM AND MAGNESIUM.
Stability Condition to Avoid:AVOID CONTACT WITH EXCESSIVE HEA,
TEMPERATURES OVER 120F, OPEN FLAMES, WELDING ARCS, RESISTANCE
HEATERS, ETC.
Hazardous Decomposition Products:RELEASING HYDROGEN CHLORIDE AND SMALL
AMOUNTS OF PHOSGENE AND CHLORINE.

Disposal

Waste Disposal Methods:ALLOW VOLATILE PORTION TO EVAPORATE IN HOOD.
ALLOW SUFFICIENT TIME FOR VAPOR TO COMPLETELY CLEAR HOOD DUCT WORK.
DISPOSE OF REMAINING MATERIAL IN ACCORDANCE WITH APPLICABLE
REGULATIONS. DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE & FEDERAL
REGULATION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.